<- RFC Index (2001..2100)
RFC 2091
Network Working Group G. Meyer
Request for Comments: 2091 Shiva
Category: Standards Track S. Sherry
Xyplex
January 1997
Triggered Extensions to RIP to Support Demand Circuits
Status of this Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Abstract
This document defines a modification which can be applied to
Bellman-Ford (distance vector) algorithm information broadcasting
protocols - for example IP RIP, Netware RIP or Netware SAP - which
makes it feasible to run them on connection oriented Public Data
Networks.
This proposal has a number of efficiency advantages over the Demand
RIP proposal (RFC 1582).
Acknowledgements
The authors wish to thank Richard Edmonstone of Shiva, Joahanna
Kruger of Xyplex, Steve Waters of DEC and Guenter Roeck of Conware
for many comments and suggestions which improved this effort.
Conventions
The following language conventions are used in the items of
specification in this document:
o MUST -- the item is an absolute requirement of the specification.
MUST is only used where it is actually required for
interoperation, not to try to impose a particular method on
implementors where not required for interoperability.
o SHOULD -- the item should be followed for all but exceptional
circumstances.
Meyer & Sherry Standards Track [Page 1]
RFC 2091 Trigger RIP January 1997
o MAY or optional -- the item is truly optional and may be followed
or ignored according to the needs of the implementor.
The words "should" and "may" are also used, in lower case, in
their more ordinary senses.
Table of Contents
1. Introduction ........................................... 2
2. Overview ............................................... 3
3. The Routing Database ................................... 5
3.1. Presumption of Reachability ...................... 6
3.2. Alternative Routes ............................... 6
3.3. Split Horizon with Poisoned Reverse .............. 7
3.4. Managing Updates ................................. 7
3.5. Retransmissions .................................. 7
4. New Packet Types ....................................... 8
4.1. Update Request (9) ............................... 9
4.2. Update Response (10) ............................. 9
4.3. Update Acknowledge (11) .......................... 10
5. Packet Formats ......................................... 10
5.1. Update Header .................................... 10
5.2. IP Routing Information Protocol Version 1 ........ 11
5.3. IP Routing Information Protocol Version 2 ........ 11
5.4. Netware Routing Information Protocol ............. 12
5.5. Netware Service Advertising Protocol ............. 12
6. Timers ................................................. 17
6.1. Database Timer ................................... 17
6.2. Hold Down Timer .................................. 17
6.3. Retransmission Timer ............................. 18
6.4. Over-subscription Timer .......................... 18
7. Security Considerations ................................ 19
Appendix A - Implementation Suggestion .................... 20
References ................................................ 21
Authors' Addresses ........................................ 22
1. Introduction
Routers are used on connection oriented networks, such as X.25 packet
switched networks and ISDN networks, to allow potential connectivity
to a large number of remote destinations. Circuits on the Wide Area
Network (WAN) are established on demand and are relinquished when the
traffic subsides. Depending on the application, the connection
between any two sites for user data might actually be short and
relatively infrequent.
Meyer & Sherry Standards Track [Page 2]
RFC 2091 Trigger RIP January 1997
Periodic broadcasting by Bellman-Ford (distance vector) algorithm
information broadcasting protocols IP RIP [1], IP RIP V2 [2] or
Netware RIP and SAP [3] generally prevents WAN circuits from being
closed. Even on fixed point-to-point links the overhead of periodic
transmission of RIP - and even more so SAP broadcasts - can seriously
interrupt normal data transfer simply through the quantity of
information which hits the line every 30 or 60 seconds.
To overcome these limitations, this specification modifies the
distance vector protocols so as to send information on the WAN only
when there has been an update to the routing database OR a change in
the reachability of a next hop router is indicated by the task which
manages connections on the WAN.
Because datagrams are not guaranteed to get through on all WAN media,
an acknowledgement and retransmission system is required to provide
reliability.
The protocols run unmodified on Local Area Networks (LANs) and so
interoperate transparently with implementations adhering to the
original specifications.
This proposal differs from Demand RIP [4] conceptually as follows:
o If a router has exchanged all routing information with its partner
and some routing information subsequently changes only the changed
information is sent to the partner.
o The receiver of routes is able to apply all changes immediately
upon receiving information from a partner.
These differences lead to further reduced routing traffic and also
require less memory than Demand RIP [4]. Demand RIP also has an
upper limit of 255 fragments in an update which is lifted in
Triggered RIP (which does not use fragmentation).
2. Overview
Multiprotocol routers are used on connection oriented Wide Area
Networks (WANs), such as X.25 packet switched networks and ISDN
networks, to interconnect LANs. By using the multiplexing properties
of the underlying WAN technology, several LANs can be interconnected
simultaneously through a single physical interface on the router.
Meyer & Sherry Standards Track [Page 3]
RFC 2091 Trigger RIP January 1997
A circuit manager provides an interface between the connectionless
network layers, IP and IPX, and the connection oriented WAN, X.25,
ISDN etc. Figure 1 shows a schematic representative stack showing
the relationship between routing protocols, the network layers, the
circuit manager and the connection oriented WAN.
-------------- --------- ---------
| RIP | | RIP | | SAP |
-------------- --------- ---------
| | |
-------------- | |
| UDP | | |
-------------- | |
| | |
-------------- ----------------
| IP | | IPX |
-------------- ----------------
| |
-------------------------------------------
| Circuit Manager |
-------------------------------------------
||||||||||
||||||||||
---------------------------
| Connection Oriented |
| WAN stack |
---------------------------
A WAN circuit manager will support a variety of network
layer protocols, on its upper interface. On its lower interface,
it may support one or more subnetworks. A subnetwork may support
a number of Virtual Circuits.
Figure 1. Representative Multiprotocol Router stack
The router has a translation table which relates the network layer
address of the next hop router to the physical address used to
establish a Virtual Circuit (VC) to it.
The circuit manager takes datagrams from the connectionless network
layer protocols and (if one is not currently available) opens a VC to
the next hop router. A VC can carry all traffic between two end-
point routers for a given network layer protocol (or with appropriate
encapsulation all network layer protocols). An idle timer (or some
other mechanism) is used to close the VC when the datagrams stop
arriving at the circuit manager.
Meyer & Sherry Standards Track [Page 4]
RFC 2091 Trigger RIP January 1997
If the circuit manager has data to forward (whether user data OR a
routing update) and fails to obtain a VC it informs the routing
application that the destination is unreachable (circuit down). The
circuit manager is then expected to perform whatever is necessary to
recover the link. Once successful, it informs the routing
application (circuit up).
In Triggered RIP, routing updates are only transmitted on the WAN
when required:
1 When a specific request for a routing update has been received.
2 When the routing database is modified by new information from
another interface.
3 When the circuit manager indicates that a destination has changed
from an unreachable (circuit down) to a reachable (circuit up)
state.
4 And also when a unit is first powered on to ensure that at least
one update is sent. This can be thought of as a transition from
circuit down to circuit up. It MAY contain no routes or services,
and is used to flush routes or services from the peer's database.
In cases 1,3 and 4 the full contents of the database is sent. In
case 2 only the latest changes are sent.
Because of the inherent unreliability of a datagram based system,
both routing requests and routing responses require acknowledgement,
and retransmission in the event of NOT receiving an acknowledgement.
3. The Routing Database
Entries in the routing database can either be permanent or temporary.
Entries learned from broadcasts on LANs are temporary. They will
expire if not periodically refreshed by further broadcasts.
Entries learned from a triggered response on the WAN are 'permanent'.
They MUST not time out in the normal course of events. Certain
events can cause these routes to time out.
Meyer & Sherry Standards Track [Page 5]
RFC 2091 Trigger RIP January 1997
3.1 Presumption of Reachability
If a routing update is received from a next hop router on the WAN,
entries in the update are thereafter always considered to be
reachable, unless proven otherwise:
o If in the normal course of routing datagrams, the circuit manager
fails to establish a connection to the next hop router, it
notifies the routing application that the next hop router is not
reachable through an internal circuit down message.
The database entries are first marked as temporary and aged
normally; Some implementations may choose to omit this initial
aging step. The routing application then marks the appropriate
database entries as unreachable for a hold down period (the normal
120 second RIP hold down timer).
o If the circuit manager is subsequently able to establish a
connection to the next hop router, it will notify the routing
application that the next hop router is reachable through an
internal circuit up message.
The routing application will then exchange messages with the next
hop router so as to re-prime their respective routing databases
with up-to-date information.
The next hop router may also be marked as unreachable if an excessive
number of retransmissions of an update go unacknowledged (see section
6.3).
Handling of circuit up and circuit down messages requires that the
circuit manager takes responsibility for establishing (or re-
establishing) the connection in the event of a next hop router
becoming unreachable. A description of the processes the circuit
manager adopts to perform this task is outside the scope of this
document.
3.2 Alternative Routes
A requirement of using Triggered RIP for propagating routing
information is that NO routing information ever gets LOST or
DISCARDED. This means that all alternative routes SHOULD be
retained.
It MAY be possible to operate with a sub-set of all alternative
routes, but this adds complexity to the protocol - which is NOT
covered in this document.
Meyer & Sherry Standards Track [Page 6]
RFC 2091 Trigger RIP January 1997
3.3 Split Horizon with Poisoned Reverse
The rules for Split Horizon with Poisoned Reverse MUST be used to
determine whether and/or how a route is advertised on an interface
running this protocol.
Split Horizon consists of omitting routes learned from a peer when
sending updates back to that peer. With Poisoned Reverse instead of
omitting those routes, they are advertised as unreachable (setting
the metric to infinity).
A route is only poisoned if it is the best route (rather than an
inferior alternative route) in the database.
Poison Reverse is necessary because a router may be advertising a
route to a network to its partner and then later learn a better route
for the same network from the partner. Without Poison Reverse the
partner will not know to discard the inferior route learned from the
first router.
3.4 Managing Routing Updates
The routing database SHOULD be considered to be a sequence of
elements ordered by the time it was last updated. If there is a
change in the best route (i.e. a new route is added or a route's
metric has changed), the route is reordered and given a new highest
sequence number.
Sending updates to a peer consists of running through the database
from the oldest entry to the newest entry. Once an entry has been
sent and acknowledged it is generally never resent. As new routing
information arrives, only the new information is sent.
3.5 Retransmissions
Handling retransmission of updates is simplest if updates are
restricted to never having more than one un-acknowledged update
outstanding - "one packet in flight". A copy of the update packet
can be kept and retransmitted until acknowledged - and then
subsequent update packets are sent in turn until the full database
(to date) has been sent and acknowledged.
Meyer & Sherry Standards Track [Page 7]
RFC 2091 Trigger RIP January 1997
Things become more complicated if several packets are sent in quick
succession without waiting for an acknowledgements between packets -
"several packets in flight":
o If packets arrive out of order they could corrupt the peer's
database. If the underlying datalink layer bundles several VCs,
it MUST guarantee to NOT reorder datagrams.
o If the elements making up a packet requiring retransmission change
because of an alteration in the database, stale incorrect
information could be sent (again new information could overtake
old information).
To guard against this when 'retransmitting' a packet when the
database is in flux the packet MUST be re-created from the database
to contain only the subset of routes which currently apply. And if
none of the routes still apply, nothing will be 'retransmitted'.
For simplicity of implementation we would advise having only one
packet in flight. However if the 'round trip' for a response and
acknowledgement is quite long this could significantly delay large
updates. See Appendix A for an understanding of the additional
complexity of managing several packets in flight.
4. New Packet Types
To support triggered updates, three new packet types MUST be
supported. For IP RIP Version 1 [1] and IP RIP Version 2 [2] these
are identified by the Command Field values shown:
o 9 - Update Request
o 10 - Update Response
o 11 - Update Acknowledge
For Netware RIP and SAP [3] the equivalent Field to distinguish
between packet types is called Operation and these take the same
values.
These Command and Operation types require the addition of a 4 octet
Update header. All three packet types contain a Version, which MUST
be 1. Update Response and Update Acknowledge also have a Sequence
Number and a Flush Flag.
Meyer & Sherry Standards Track [Page 8]
RFC 2091 Trigger RIP January 1997
4.1 Update Request
The Update Request has the Command/Operation value 9.
It is a request to the peer system to send ALL appropriate elements
in its routing database. It is retransmitted at periodic intervals
(every 5 seconds) until an Update Response message is received with
the Flush flag set.
An Update Request is transmitted in the following circumstances:
o Firstly when the router is powered on.
o Secondly when the circuit manager indicates a destination has been
in an unreachable (circuit down) state and changes to a reachable
(circuit up) state.
An Update Request may also be sent at other times to compensate for
discarding non-optimal routing information or if an Update Response
continues to be unacknowledged (see section 6.3).
4.2 Update Response
The Update Response has the Command/Operation value 10.
It is a message containing zero or more routes in an update. It is
retransmitted at periodic intervals until an Update Acknowledge is
received.
An Update Response message MUST be sent:
o In response to an Update Request. The Update Response MUST have
the Flush flag set. Other Update Responses should NOT be sent
until an Update Acknowledge has been received acknowledging the
Flush flag.
The remainder of the database MUST then be sent as a series of
Update Responses with the Flush flag NOT set.
o An Update Response with the Flush flag set MUST also be sent at
power on to flush the peer's routing table learned from a previous
incarnation. This Update Response SHOULD NOT contain any routes.
This avoids any possibility of an acknowledgement being received
to a response sent BEFORE the unit was restarted causing confusion
about which routes are being acknowledged.
Update Response messages continue to be sent any time there is fresh
routing information to be propagated.
Meyer & Sherry Standards Track [Page 9]
RFC 2091 Trigger RIP January 1997
Each new Update Response is given a different Sequence Number. The
Sequence Number only has 'meaning' to the sender of the Update
Response. The same Update Response sent to different peers MAY have
a different Sequence Number.
An Update Response packet with the Flush flag set MUST be sent to a
peer:
o At power on.
o In response to an Update Request packet.
o After transitioning from a circuit down to a circuit up state.
After sending an Update Flush, the full database MUST be sent
subsequently.
4.3 Update Acknowledge
The Update Acknowledge has the Command/Operation value 11.
It is a message sent in response to every Update Response packet
received. If the Update Response packet has the flush flag set then
so should the Update Acknowledge packet.
5. Packet Formats
5.1 Update Header
To support the mechanism outlined in this proposal the packet format
for RIP Version 1 [1], RIP Version 2 [2] and Netware RIP and SAP [3]
are modified to include an additional small header when using
Commands Update Request (9), Update Response (10) and Update
Acknowledge (11). Commands are called Operations in Netware.
Update Request (9):
0 1 2 3 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Version (1) | must be zero (3) |
+-------------------------------+-------------------------------+
Meyer & Sherry Standards Track [Page 10]
RFC 2091 Trigger RIP January 1997
Update Response (10) and Update Acknowledge (11):
0 1 2 3 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Version (1) | Flush (1) | Sequence Number (2) |
+-------------------------------+-------------------------------+
Four octet Update headers, with each tick mark representing one
bit. All fields are coded in network byte order (big-endian).
Figure 2. Update Headers.
Version MUST be 1 in all headers. Any packets received for a
different Version MUST be silently discarded.
The Sequence Number MUST be incremented every time a new Update
Response packet is sent on the WAN. The Sequence Number is unchanged
for retransmissions. The Sequence Number wraps round at 65535.
Flush is set to 1 in an Update Response if the peer is required to
start timing out its entries - otherwise it is set to zero. Any
other values MUST be silently discarded.
The peer returns an Update Acknowledge containing the same Sequence
Number and Flush.
5.2 IP Routing Information Protocol Version 1
IP RIP [1] is a UDP-based protocol which generally sends and receives
datagrams on UDP port number 520.
To support the mechanism outlined in this proposal the packet format
for RIP Version 1 [1] is modified when using Commands Update Request
(9), Update Response (10) and Update Acknowledge (11). See Figure 3.
5.3 IP Routing Information Protocol Version 2
IP RIP Version 2 [2] is an enhancement to IP RIP Version 1 which
allows RIP updates to include subnetting information.
To support the mechanism outlined in this proposal the packet format
for RIP Version 2 [2] is modified when using Commands Update Request
(9), Update Response (10) and Update Acknowledge (11). See Figure 4.
Meyer & Sherry Standards Track [Page 11]
RFC 2091 Trigger RIP January 1997
5.4 Netware Routing Information Protocol
Netware [3] supports a mechanism that allows routers on an
internetwork to exchange routing information using the Routing
Information Protocol (RIP) which runs over the Internetwork Packet
Exchange (IPX) protocol using socket number 453h.
To support the mechanism outlined in this proposal the packet format
for Novell RIP [3] is modified when using Operations Update Request
(9), Update Response (10) and Update Acknowledge (11). See Figure 5.
5.5 Netware Service Advertising Protocol
Netware [3] also supports a mechanism that allows servers on an
internetwork to advertise their services by name and type using the
Service Advertising Protocol (SAP) which runs over the Internetwork
Packet Exchange (IPX) protocol using socket number 452h. SAP
operates on similar principals to running RIP. Routers act as SAP
agents, collecting service information from different networks and
relay it to interested parties.
To support the mechanism outlined in this proposal the packet format
for Novell SAP [3] is modified when using Operations Update Request
(9), Update Response (10) and Update Acknowledge (11). See Figure 6.
0 1 2 3 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Command (1) | RIP Version (1)| must be zero (2) |
+---------------+---------------+-------------------------------+
0 1 2 3 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Update Header (4) |
+-------------------------------+-------------------------------+
Meyer & Sherry Standards Track [Page 12]
RFC 2091 Trigger RIP January 1997
Update Response then has up to 25 routing entries (each 20 octets):
0 1 2 3 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Address Family Identifier (2) | must be zero (2) |
+-------------------------------+-------------------------------+
| IP address (4) |
+---------------------------------------------------------------+
| must be zero (4) |
+---------------------------------------------------------------+
| must be zero (4) |
+---------------------------------------------------------------+
| Metric (4) |
+---------------------------------------------------------------+
.
.
The format of an IP RIP datagram in octets, with each tick mark
representing one bit. All fields are coded in network byte order
(big-endian).
The four octets of the Update header are included in Update Request
(Command 9), Update Response (10) and Update Acknowledge (11)
packets. They are not present in packet types in the original RIP
Version 1 specification.
Figure 3. IP RIP Version 1 packet format
Meyer & Sherry Standards Track [Page 13]
RFC 2091 Trigger RIP January 1997
0 1 2 3 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Command (1) |RIP Version (1)| must be zero (2) |
+---------------+---------------+-------------------------------+
0 1 2 3 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Update Header (4) |
+-------------------------------+-------------------------------+
Update Response then has up to 25 routing entries (each 20 octets):
0 1 2 3 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Address Family Identifier (2) | Route Tag (2) |
+-------------------------------+-------------------------------+
| IP address (4) |
+---------------------------------------------------------------+
| Subnet Mask (4) |
+---------------------------------------------------------------+
| Next Hop (4) - must be zero |
+---------------------------------------------------------------+
| Metric (4) |
+---------------------------------------------------------------+
.
.
The format of an IP RIP Version 2 datagram in octets, with each
tick mark representing one bit. All fields are coded in network
byte order (big-endian).
The four octets of the Update header are included in Update Request
(Command 9), Update Response (10) and Update Acknowledge (11)
Packets. They are not present in packet types in the original RIP
Version 2 specification.
Next Hop MUST be zero, since Triggered RIP can NOT advertise routes
on behalf of other WAN routers.
If authentication is used it immediately follows the Update header.
Figure 4. IP RIP Version 2 packet format
Meyer & Sherry Standards Track [Page 14]
RFC 2091 Trigger RIP January 1997
0 1 1
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Operation (2) |
+---------------+---------------+
0 1 2 3 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Update Header (4) |
+-------------------------------+-------------------------------+
Update Response then has up to 50 routing entries (each 8 octets):
0 1 2 3 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Network Number (4) |
+---------------------------------------------------------------+
| Number of Hops (2) | Number of Ticks (2) |
+---------------------------------------------------------------+
.
.
The format of a Netware RIP datagram in octets, with each tick mark
representing one bit. All fields are coded in network byte order
(big-endian).
The four octets of the Update header are included in Update Request
(Operation 9), Update Response (10) and Update Acknowledge (11)
packets. They are not present in packet types in the original
Novell RIP specification.
Figure 5. Netware RIP packet format
Meyer & Sherry Standards Track [Page 15]
RFC 2091 Trigger RIP January 1997
0 1 1
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Operation (2) |
+---------------+---------------+
0 1 2 3 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Update Header (4) |
+-------------------------------+-------------------------------+
Update Response then has up to 8 service entries (each 64 octets):
0 1 2 3 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Service Type (2) | |
+-------------------------------+ |
| Service Name (48) |
| . |
.
. +-------------------------------+
| . | Network Address (4) |
+-------------------------------+-------------------------------+
| Network Address (cont) | |
+-------------------------------+ |
| Node Address (6) |
+-------------------------------+-------------------------------+
| Socket Address (2) | Hops to Server (2) |
+-------------------------------+-------------------------------+
.
.
The format of a Netware SAP datagram in octets, with each tick mark
representing one bit. All fields are coded in network byte order
(big-endian).
The four octets of the Update header are included in Update Request
(Operation 9), Update Response (10) and Update Acknowledge (11)
packets. They are not present in packet types in the original
Novell SAP specification.
Figure 6. Netware SAP packet format
Meyer & Sherry Standards Track [Page 16]
RFC 2091 Trigger RIP January 1997
6. Timers
Three timers are supported to handle the triggered update mechanism:
o Database timer.
o Hold down timer.
o Retransmission timer.
An optional over-subscription timer MAY also be supported.
6.1 Database Timer
Routes learned by an Update Response are normally considered to be
permanent.
When an Update Response with the Flush flag set is received, all
routes learned from that next hop router should start timing out as
if they had (just) been learned from a conventional Response (Command
2).
Namely each route exists while the database entry timer (usually 180
seconds) is running and is advertised on other interfaces as if still
present. The route is then advertised as unreachable while a further
hold down timer is allowed to expire.
6.2 Hold down Timer
A hold down timer of 120 seconds is started on a route:
o When the database timer for the route expires.
o When a formerly reachable route changes to unreachable in an
incoming response.
o When a circuit down is received from the circuit manager.
While the hold down timer is running routes are advertised as
unreachable on other interfaces.
When the hold down timer expires the route MAY be deleted from the
database PROVIDING its unreachability has been successfully
propagated to all WAN destinations, or the remaining WAN destinations
are in a circuit down state. If a route can not be deleted when the
hold-down timer expires, it MAY subsequently be deleted when each and
every peer is either up-to-date or is in a circuit down state.
Meyer & Sherry Standards Track [Page 17]
RFC 2091 Trigger RIP January 1997
If the hold down timer is already running it is NOT reset by any
events which would start the hold down timer.
6.3 Retransmission Timer
The routing task runs a retransmission timer:
o An Update Request packet is retransmitted periodically until an
Update Flush packet is received. An Update Flush packet is an
Update Response packet with the Flush field set. It need not
contain routes.
o An Update Response packet is retransmitted periodically until an
Update Acknowledge packet is received containing the same Sequence
Number.
With call set up time on the WAN being of the order of a second, a
value of 5 seconds for the retransmission timer is appropriate.
To prevent against failures in the circuit manager a limit SHOULD be
placed on the number of retransmissions. If no response has been
received after a configurable length of time (say 180 seconds) routes
via the next hop router are marked as unreachable, the hold down
timer is started and the entry is advertised as unreachable on other
interfaces.
The next hop router may then be polled with Update Requests at a
reduced frequency. A suitable poll interval would be of the order of
minutes rather than seconds. Alternatively an Update Request could
be initiated by administrative action. When a response is received
the routers should perform a complete exchange of routing
information.
6.4 Over-subscription Timer
Over-subscription is where there are more next hop routers to send
updates to on the WAN than there are channels. For example 3 next
hop routers accessed by an ISDN Basic Rate Interface (BRI) which can
only support 2 calls simultaneously.
To avoid route oscillation routes may NOT be marked unreachable
immediately on receiving a circuit down message from the circuit
manager. A timeout MAY be used to delay marking the routes
unreachable for sufficiently long to allow the calls to 'time
division multiplex' over the available channels. A timeout as long
as the regular 180 second RIP route timeout MAY be suitable. In
general the greater the over-subscription, the longer the time out
should be.
Meyer & Sherry Standards Track [Page 18]
RFC 2091 Trigger RIP January 1997
Implementations wishing to support over-subscription may implement
the delay within the circuit manager or within the routing
application.
If the delay is implemented within the routing application the
routing entries MUST NOT start timing out during the delay. This
allows the circuit up message to be ignored if the timeout after
receiving the circuit down has still to expire. This avoids any
confusion if the peer had previously issued a Route Flush command and
was part way through an update.
7. Security Considerations
The circuit manager is required to be provided with a list of
physical addresses to enable it to establish a call to the next hop
router. The circuit manager SHOULD only allow incoming calls to be
accepted from the same well defined list of routers.
Elsewhere in the system there will be a set of logical address and
physical address tuples to enable the network protocols to run over
the correct circuit. This may be a lookup table, or in some
instances there may be an algorithmic conversion between the two
addresses.
The routing (or service advertising) task MUST be provided with a
list of logical addresses to which triggered updates are to be sent
on the WAN. The list MAY be a subset of the list of next hop routers
maintained by the circuit manager.
RIP Version 2 also allows further authentication of Triggered RIP
packets.
Meyer & Sherry Standards Track [Page 19]
RFC 2091 Trigger RIP January 1997
Appendix A - Implementation Suggestion
This section suggests how the database might be structured to handle
Triggered RIP.
Each entry in the database is given a unique route number. Every
time a best route to a network changes, a global route number is
incremented and the changed route is given the new route number.
Note that this route number is completely internal to the router and
has no bearing on the Sequence Number sent in Update Responses sent
to the peer.
The route number size should be large enough so as not to wrap round
- or the routes can be renumbered before it becomes a problem. Re-
numbering requires that the database environment is stable (No Update
Responses are queued awaiting Acknowledgement)
Is is probably easier to manage the routes if they are also chained
together using a pointer to a later (and possibly also a pointer to
an earlier) entry which reflect the route number/age.
Performing a complete update then consists of running though the
routes from the oldest to the latest and sending them out in Update
Responses. Subsequent changes to the database are treated as sending
out only the changed entries (from the previous latest to the new
latest).
When allowing for several packets in flight care must be taken with
retransmissions. An Update Response 'retransmission' MAY be
different from the original. When transmitting a sequence of Update
Responses each Response packet contains a number of routes which is a
represented by a series of routes with consecutive route numbers.
Consider sending three Update Responses with Sequence numbers 10,11
and 12 each containing 10 routes:
Sequence Number Routes represented by Route Numbers
10 101, 102, 103, 104, 105, 106, 107, 108, 109, 110
11 111, 112, 113, 114, 115, 116, 117, 118, 119, 120
12 121, 122, 123, 124, 125, 126, 127, 128, 129, 130
Meyer & Sherry Standards Track [Page 20]
RFC 2091 Trigger RIP January 1997
If these Update Responses are NOT acknowledged, but in the meantime
the routing database has changed and the routes represented by route
numbers 104, 112 - 116 and 127 have changed and been assigned new
route numbers 131 - 137, the retransmission will look like:
Sequence Number Routes represented by Route Numbers
10 101, 102, 103, 105, 106, 107, 108, 109, 110
11 111, 117, 118, 119, 120
12 121, 122, 123, 124, 125, 126, 128, 129, 130
13 131, 132, 133, 134, 135, 136, 137
To perform a retransmission it is VERY IMPORTANT that the
retransmission contains only the SUB-SET of route numbers which
currently apply. If there are NO suitable routes to send, it is not
necessary to send an empty retransmission.
An alternative 'retransmission' strategy is to always use different
sequence numbers when resending updates. Consider transmitting
packets with sequence numbers 10 through 20 - and responses are
received from all packets except those with sequence numbers 14 and
17. In this case only the data in packets 10 through 13 can be
considered to be acknowledged. The data from packet 14 onwards MUST
be re-sent and given new sequence numbers starting at 21.
References
[1] Hedrick. C., "Routing Information Protocol", RFC 1058, Rutgers
University, June 1988.
[2] Malkin. G., "RIP Version 2 - Carrying Additional Information",
RFC 1723, Xylogics, November 1994.
[3] Novell Incorporated., "IPX Router Specification", Version 1.20,
October 1993.
[4] Meyer. G., "Extensions to RIP to Support Demand Circuits",
Spider Systems, February 1994.
Meyer & Sherry Standards Track [Page 21]
RFC 2091 Trigger RIP January 1997
Authors' Address:
Gerry Meyer
Shiva
Stanwell Street
Edinburgh EH6 5NG
Scotland, UK
Phone: (UK) 131 554 9424
Fax: (UK) 131 467 7749
Email: gerry@europe.shiva.com
Steve Sherry
Xyplex
295 Foster St.
Littleton, MA 01460
Phone: (US) 508 952 4745
Fax: (US) 508 952 4887
Email: shs@xyplex.com
Meyer & Sherry Standards Track [Page 22]