<- RFC Index (4701..4800)
RFC 4777
Obsoletes RFC 2877
Network Working Group T. Murphy, Jr.
Request for Comments: 4777 P. Rieth
Obsoletes: 2877 J. Stevens
Category: Informational IBM
November 2006
IBM's iSeries Telnet Enhancements
Status of This Memo
This memo provides information for the Internet community. It does
not specify an Internet standard of any kind. Distribution of this
memo is unlimited.
Copyright Notice
Copyright (C) The IETF Trust (2006).
IESG Note
This RFC is not a candidate for any level of Internet Standard. The
IETF disclaims any knowledge of the fitness of this RFC for any
purpose and in particular notes that the decision to publish is not
based on IETF review for such things as security, congestion control,
or inappropriate interaction with deployed protocols. The RFC Editor
has chosen to publish this document at its discretion. Readers of
this document should exercise caution in evaluating its value for
implementation and deployment. See RFC 3932 for more information.
Abstract
This document describes the interface to the Telnet server on IBM's
iSeries line of midrange business computers. This interface allows
Telnet clients to request a Telnet terminal or printer session using
specific session attributes related to device names, encryption,
language support, auto-sign-on, response codes, session association,
etc.
These support functions are implemented primarily using the Telnet
Environment option negotiation RFC 1572 to define new USERVAR
variables that will be recognized by iSeries Telnet server.
Murphy, et al. Informational [Page 1]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
Table of Contents
1. Introduction ....................................................2
2. Standard Telnet Option Negotiation ..............................3
3. Enhanced Telnet Option Negotiation ..............................4
4. Enhanced Display Emulation Support ..............................7
5. Enhanced Display Auto-Sign-On and Password Encryption ...........9
5.1. Data Encryption Standard (DES) Password Substitutes .......13
5.2. Secure Hash Algorithm (SHA) Password Substitutes ..........16
6. Kerberos Services Ticket Automatic Sign-On Support .............18
7. Device Name Collision Processing ...............................21
8. Enhanced Printer Emulation Support .............................22
9. Telnet Printer Terminal Types ..................................23
10. Startup Response Record for Printer and Display Devices .......25
10.1. Example of a Success Response Record .....................26
10.2. Example of an Error Response Record ......................27
10.3. Example of a Response Record with Device Name Retry ......28
10.4. Response Codes ...........................................31
11. Printer Steady-State Pass-Through Interface ...................33
11.1. Example of a Print Record ................................35
11.2. Example of a Print Complete Record .......................37
11.3. Example of a Null Print Record ...........................37
12. End-to-End Print Example ......................................39
13. Security Considerations .......................................44
14. IANA Considerations ...........................................44
15. Normative References ..........................................44
16. Informative References ........................................44
17. Relation to Other RFCs ........................................45
1. Introduction
The iSeries Telnet server enables clients to negotiate both terminal
and printer device names through Telnet Environment Options
Negotiations [RFC1572].
This allows Telnet servers and clients to exchange environment
information using a set of standard or custom variables. By using a
combination of both standard VARs and custom USERVARs, the iSeries
Telnet server allows client Telnet to request a pre-defined specific
device by name.
If no pre-defined device exists, then the device will be created,
with client Telnet having the option to negotiate device attributes,
such as the code page, character set, keyboard type, etc.
Since printers can now be negotiated as a device name, new terminal
types have been defined to request printers. For example, you can
Murphy, et al. Informational [Page 2]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
now negotiate "IBM-3812-1" and "IBM-5553-B01" as valid TERMINAL-TYPE
options [RFC1091].
Finally, the iSeries Telnet server will allow exchange of user
profile and password information, where the password may be in either
plain text or encrypted form. If a valid combination of profile and
password is received, then the client is allowed to bypass the sign-
on panel. The local server setting of the QRMTSIGN system value must
be either *VERIFY or *SAMEPRF for the bypass of the sign-on panel to
succeed.
2. Standard Telnet Option Negotiation
Telnet server option negotiation [RFC855] typically begins with the
issuance, by the server, of an invitation to engage in terminal type
negotiation with the Telnet client (DO TERMINAL-TYPE) [RFC1091]. The
client and server then enter into a series of sub-negotiations to
determine the level of terminal support that will be used. After the
terminal type is agreed upon, the client and server will normally
negotiate a required set of additional options (EOR [RFC885], BINARY
[RFC856], SGA [RFC858]) that are required to support "transparent
mode" or full screen 5250/3270 block mode support. As soon as the
required options have been negotiated, the server will suspend
further negotiations and begin with initializing the actual virtual
device on the iSeries. A typical exchange might start as follows:
iSeries Telnet server Enhanced Telnet client
-------------------------- -------------------------
IAC DO TERMINAL-TYPE -->
<-- IAC WILL TERMINAL-TYPE
IAC SB TERMINAL-TYPE SEND
IAC SE -->
IAC SB TERMINAL-TYPE IS
<-- IBM-5555-C01 IAC SE
IAC DO EOR -->
<-- IAC WILL EOR
<-- IAC DO EOR
IAC WILL EOR -->
.
.
(other negotiations) .
Murphy, et al. Informational [Page 3]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
Actual bytes transmitted in the above example are shown in hex below.
iSeries Telnet server Enhanced Telnet client
-------------------------- -------------------------
FF FD 18 -->
<-- FF FB 18
FF FA 18 01 FF F0 -->
FF FA 18 00 49 42 4D 2D
35 35 35 35 2D 43 30 31
<-- FF F0
FF FD 19 -->
<-- FF FB 19
<-- FF FD 19
FF FB 19 -->
.
.
(other negotiations) .
Some negotiations are symmetrical between client and server, and some
are negotiated in one direction only. Also, it is permissible and
common practice to bundle more than one response or request, or to
combine a request with a response, so in practice the actual exchange
may look different from what is shown above.
3. Enhanced Telnet Option Negotiation
In order to accommodate the new environment option negotiations, the
server will bundle an environment option invitation along with the
standard terminal type invitation request to the client.
A client should either send a negative acknowledgment (WONT NEW-
ENVIRON), or at some point after completing terminal-type
negotiations, but before completing the full set of negotiations
required for 5250 transparent mode, engage in environment option
sub-negotiation with the server. A maximum of 1024 bytes of
environment strings may be sent to the server. A recommended
sequence might look like the following:
Murphy, et al. Informational [Page 4]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
iSeries Telnet server Enhanced Telnet client
-------------------------- -------------------------
IAC DO NEW-ENVIRON
IAC DO TERMINAL-TYPE -->
(2 requests bundled)
<-- IAC WILL NEW-ENVIRON
IAC SB NEW-ENVIRON SEND
VAR IAC SE -->
IAC SB NEW-ENVIRON IS
VAR "USER" VALUE "JONES"
USERVAR "DEVNAME"
VALUE "MYDEVICE07"
<-- IAC SE
<-- IAC WILL TERMINAL-TYPE
(do the terminal type
sequence first)
IAC SB TERMINAL-TYPE SEND
IAC SE -->
IAC SB TERMINAL-TYPE IS
<-- IBM-5555-C01 IAC SE
(terminal type negotiations
completed)
IAC DO EOR -->
(server will continue
with normal transparent
mode negotiations)
<-- IAC WILL EOR
.
.
(other negotiations) .
Murphy, et al. Informational [Page 5]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
Actual bytes transmitted in the above example are shown in hex below.
iSeries Telnet server Enhanced Telnet client
-------------------------- -------------------------
FF FD 27
FF FD 18 -->
(2 requests bundled)
<-- FF FB 27
FF FA 27 01 00 FF F0 -->
FF FA 27 00 00 55 53 45
52 01 4A 4F 4E 45 53 03
44 45 56 4E 41 4D 45 01
4D 59 44 45 56 49 43 45
<-- 30 37 FF F0
<-- FF FB 18
(do the terminal type
sequence first)
FF FA 18 01 FF F0 -->
FF FA 18 00 49 42 4D 2D
35 35 35 35 2D 43 30 31
<-- FF F0
FF FD 19 -->
(server will continue
with normal transparent
mode negotiations)
<-- FF FB 19
.
.
(other negotiations) .
Telnet environment options defines 6 standard VARs: USER, JOB, ACCT,
PRINTER, SYSTEMTYPE, and DISPLAY. The USER standard VAR will hold
the value of the iSeries user profile name to be used in auto-sign-on
requests. The Telnet server will make no direct use of the
additional 5 VARs, nor are any of them required to be sent. All
standard VARs and their values that are received by the Telnet server
will be placed in a buffer, along with any USERVARs received
(described below), and made available to a registered initialization
exit program to be used for any purpose desired.
There are some reasons you may want to send NEW-ENVIRON negotiations
prior to TERMINAL-TYPE negotiations. With an iSeries Telnet server,
several virtual device modes can be negotiated: 1) VTxxx device, 2)
3270 device, and 3) 5250 device (includes Network Station). The
virtual device mode selected depends on the TERMINAL-TYPE negotiated
plus any other Telnet option negotiations necessary to support those
modes. The iSeries Telnet server will create the desired virtual
device at the first opportunity it thinks it has all the requested
Murphy, et al. Informational [Page 6]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
attributes needed to create the device. This can be as early as
completion of the TERMINAL-TYPE negotiations.
For the case of Transparent mode (5250 device), the moment TERMINAL-
TYPE, BINARY, and EOR options are negotiated, the Telnet server will
go create the virtual device. Receiving any NEW-ENVIRON negotiations
after these option negotiations are complete will result in the NEW-
ENVIRON negotiations having no effect on device attributes, as the
virtual device will have already been created.
So, for Transparent mode, NEW-ENVIRON negotiations are effectively
closed once EOR is negotiated, since EOR is generally the last option
done.
For other devices modes (such as VTxxx or 3270), you cannot be sure
when the iSeries Telnet server thinks it has all the attributes to
create the device. Recall that NEW-ENVIRON negotiations are
optional, and therefore the iSeries Telnet server need not wait for
any NEW-ENVIRON options prior to creating the virtual device. It is
in the clients' best interest to send NEW-ENVIRON negotiations as
soon as possible, preferably before TERMINAL-TYPE is negotiated.
That way, the client can be sure that the requested attributes were
received before the virtual device is created.
4. Enhanced Display Emulation Support
Telnet environment option USERVARs have been defined to allow a
compliant Telnet client more control over the Telnet server virtual
device on the iSeries and to provide information to the Telnet server
about the client. These USERVARs allow the client Telnet to create
or select a previously created virtual device. If the virtual device
does not exist and must be created, then the USERVAR variables are
used to create and initialize the device attributes. If the virtual
device already exists, the device attributes are modified.
Murphy, et al. Informational [Page 7]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
The USERVARs defined to accomplish this are:
USERVAR VALUE EXAMPLE DESCRIPTION
-------- ---------------- -------------- -------------------
DEVNAME us-ascii char(x) MYDEVICE07 Display device name
KBDTYPE us-ascii char(3) USB Keyboard type
CODEPAGE us-ascii char(y) 437 Code page
CHARSET us-ascii char(y) 1212 Character set
IBMSENDCONFREC us-ascii char(3) YES | NO Startup Response
Record desired
IBMASSOCPRT us_ascii char(x) RFCPRT Printer associated
with display
device
x - up to a maximum of 10 characters
y - up to a maximum of 5 characters
For a description of the KBDTYPE, CODEPAGE, and CHARSET parameters
and their permissible values, refer to Chapter 8 in the
Communications Configuration Reference [COMM-CONFIG] and also to
Appendix C in National Language Support [NLS-SUPPORT].
The CODEPAGE and CHARSET USERVARs must be associated with a KBDTYPE
USERVAR. If either CODEPAGE or CHARSET are sent without KBDTYPE,
they will default to system values. A default value for KBDTYPE can
be sent to force CODEPAGE and CHARSET values to be used.
iSeries system objects such as device names, user profiles, plain
text passwords, programs, libraries, etc., are required to be
specified in English uppercase. This includes:
any letter (A-Z), any number (0-9), special characters (# $ _ @)
Therefore, where us-ascii is specified for VAR or USERVAR values, it
is recommended that uppercase ASCII values be sent, which will be
converted to Extended Binary Coded Decimal Interchange Code (EBCDIC)
by the Telnet server.
A special case occurs for encrypted passwords (described in the next
section), where both the initial password and user profile used to
build the encrypted password must be EBCDIC English uppercase, in
order to be properly authenticated by the Telnet server.
The IBMASSOCPRT USERVAR is used to provide the device name of a
printer that will be associated with the display device that is
created. The device description of the printer name provided must
currently exist on the Telnet server system. The IBMSENDCONFREC
USERVAR is used by the enhanced Telnet client to inform the Telnet
Murphy, et al. Informational [Page 8]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
server that a display Startup Response Record should be sent to the
client. This record communicates the name of the actual display
device acquired. If the attempt is unsuccessful, the reason code
will be set to provide additional information on why the attempt
failed. In addition to the device name and reason code, the Startup
Response Record will contain the name of the Telnet server system.
For more details on the Startup Response Record, see Section 11 of
this document.
5. Enhanced Display Auto-Sign-On and Password Encryption
To allow password encryption, new IBMRSEED and IBMSUBSPW USERVARs
will be used to exchange seed and substitute passwords information.
IBMRSEED will carry a random seed to be used in both the Data
Encryption Standard (DES) and Secure Hash Algorithm (SHA) password
encryption, and IBMSUBSPW will carry the encrypted copy of the
password.
The DES encryption would use the same 7-step DES-based password
substitution scheme as APPC and Client Access. For a description of
DES encryption, refer to Federal Information Processing Standards
Publications (FIPS) 46-2 [FIPS-46-2] and 81 [FIPS-81].
The SHA encryption is described in Federal Information Processing
Standards Publication 180-1 [FIPS-180-1].
The FIPS documents can be found at the Federal Information Processing
Standards Publications link:
http://www.itl.nist.gov/fipspubs/by-num.htm
If encrypted password exchange is not required, plain text password
exchange is permitted using the same USERVARs defined for encryption.
For this case, the random client seed should be set either to an
empty value (preferred method) or to hexadecimal zeros to indicate
the password is not encrypted, but is plain text.
It should be noted that security of plain text password exchange
cannot be guaranteed unless the network is physically protected or a
trusted network (such as an intranet). If your network is vulnerable
to IP address spoofing or directly connected to the Internet, you
should engage in encrypted password exchange to validate a client's
identity.
Additional VARs and USERVARs have also been defined to allow an
auto-sign-on user greater control over their startup environment,
Murphy, et al. Informational [Page 9]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
similar to what is supported using the Open Virtual Terminal
(QTVOPNVT) API [SYSTEM-API].
The standard VARs supported to accomplish this are:
VAR VALUE EXAMPLE DESCRIPTION
-------- ---------------- ---------------- -------------------
USER us-ascii char(x) USERXYZ User profile name
x - up to a maximum of 10 characters
The custom USERVARs defined to accomplish this are:
USERVAR VALUE EXAMPLE DESCRIPTION
-------- ---------------- ---------------- -----------------
IBMRSEED binary(8) 8-byte hex field Random client
seed
IBMSUBSPW binary(128) 128-byte hex field Substitute
password
IBMCURLIB us-ascii char(x) QGPL Current library
IBMIMENU us-ascii char(x) MAIN Initial menu
IBMPROGRAM us-ascii char(x) QCMD Program to call
x - up to a maximum of 10 characters
In order to communicate the server random seed value to the client,
the server will request a USERVAR name made up of a fixed part (the 8
characters "IBMRSEED") immediately followed by an 8-byte hexadecimal
variable part, which is the server random seed. The client generates
its own 8-byte random seed value and uses both seeds to encrypt the
password. Both the encrypted password and the client random seed
value are then sent to the server for authentication. Telnet
environment option rules will need to be adhered to when transmitting
the client random seed and substituted password values to the server.
Specifically, since a typical environment string is a variable length
hexadecimal field, the hexadecimal fields are required to be escaped
and/or byte stuffed according to the RFC 854 [RFC854], where any
single byte could be misconstrued as a Telnet IAC or other Telnet
option negotiation control character. The client must escape and/or
byte stuff any bytes that could be seen as a Telnet environment
option, specifically VAR, VALUE, ESC, and USERVAR.
If you use the IBMSENDCONFREC USERVAR, as described in Section 5 of
this document, with a value of YES along with the automatic sign-on
USERVARs described above, you will receive a Startup Response Record
that will contain a response code informing your Telnet client of the
success or failure of the automatic sign-on attempt. See Section 11
of this document for details on the Startup Response Record.
Murphy, et al. Informational [Page 10]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
The following illustrates the encrypted case:
iSeries Telnet server Enhanced Telnet client
-------------------------- -------------------------------
IAC DO NEW-ENVIRON -->
<-- IAC WILL NEW-ENVIRON
IAC SB NEW-ENVIRON SEND
USERVAR "IBMRSEEDxxxxxxxx"
USERVAR "IBMSUBSPW"
VAR USERVAR IAC SE -->
IAC SB NEW-ENVIRON IS
VAR "USER" VALUE "DUMMYUSR"
USERVAR "IBMRSEED" VALUE "yyyyyyyy"
USERVAR "IBMSUBSPW" VALUE "zzzzzzzz"
<-- IAC SE
.
.
(other negotiations) .
In this example, "xxxxxxxx" is an 8-byte hexadecimal random server
seed, "yyyyyyyy" is an 8-byte hexadecimal random client seed, and
"zzzzzzzz" is an 8-byte hexadecimal encrypted password (if the DES
encryption algorithm was used) or a 20-byte hexadecimal encrypted
password (if the SHA encryption algorithm was used). If the password
is not valid, then the sign-on panel is not bypassed. If the
password is expired, then the sign-on panel is not bypassed.
Actual bytes transmitted in the above example are shown in hex below,
where the server seed is "7D3E488F18080404", the client seed is
"4E4142334E414233", and the DES encrypted password is
"DFB0402F22ABA3BA". The user profile used to generate the encrypted
password is "44554D4D59555352" (DUMMYUSR), with a plain text password
of "44554D4D595057" (DUMMYPW).
Murphy, et al. Informational [Page 11]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
iSeries Telnet server Enhanced Telnet client
-------------------------- -------------------------
FF FD 27 -->
<-- FF FB 27
FF FA 27 01 03 49 42 4D
52 53 45 45 44 7D 3E 48
8F 18 08 04 04 03 49 42
4D 53 55 42 53 50 57 03
00 FF F0 -->
FF FA 27 00 00 55 53 45
52 01 44 55 4D 4D 59 55
53 52 03 49 42 4D 52 53
45 45 44 01 4E 41 42 33
4E 41 42 33 03 49 42 4D
53 55 42 53 50 57 01 DF
B0 40 2F 22 AB A3 BA FF
<-- F0
The following illustrates the plain text case:
iSeries Telnet server Enhanced Telnet client
-------------------------- -------------------------
IAC DO NEW-ENVIRON -->
<-- IAC WILL NEW-ENVIRON
IAC SB NEW-ENVIRON SEND
USERVAR "IBMRSEEDxxxxxxxx"
USERVAR "IBMSUBSPW"
VAR USERVAR IAC SE -->
IAC SB NEW-ENVIRON IS
VAR "USER" VALUE "DUMMYUSR"
USERVAR "IBMRSEED" VALUE
USERVAR "IBMSUBSPW" VALUE "yyyyyyyy"
<-- IAC SE
.
.
(other negotiations) .
In this example, "xxxxxxxx" is an 8-byte hexadecimal random server
seed, and "yyyyyyyyyy" is a 128-byte us-ascii client plain text
password. If the password has expired, then the sign-on panel is not
bypassed.
Actual bytes transmitted in the above example are shown in hex below,
where the server seed is "7D3E488F18080404", the client seed is
empty, and the plain text password is "44554D4D595057" (DUMMYPW).
The user profile used is "44554D4D59555352" (DUMMYUSR).
Murphy, et al. Informational [Page 12]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
iSeries Telnet server Enhanced Telnet client
-------------------------- -------------------------
FF FD 27 -->
<-- FF FB 27
FF FA 27 01 03 49 42 4D
52 53 45 45 44 7D 3E 48
8F 18 08 04 04 03 49 42
4D 53 55 42 53 50 57 03
00 FF F0 -->
FF FA 27 00 00 55 53 45
52 01 44 55 4D 4D 59 55
53 52 03 49 42 4D 52 53
45 45 44 01 03 49 42 4D
53 55 42 53 50 57 01 44
<-- 55 4D 4D 59 50 57 FF F0
5.1. Data Encryption Standard (DES) Password Substitutes
Both APPC and Client Access use well-known DES encryption algorithms
to create encrypted passwords. A Network Station or Enhanced Client
can generate compatible encrypted passwords if it follows these
steps, details of which can be found in the Federal Information
Processing Standards 46-2 [FIPS-46-2].
1) Padded_PW = Left justified user password padded to the right with
'40'X to 8 bytes.
The user's password must be left justified in an 8-byte variable
and padded to the right with '40'X up to an 8-byte length. If the
user's password is 8 bytes in length, no padding will occur. For
computing password substitutes for passwords of length 9 and 10,
see "Handling passwords of length 9 and 10" below. Passwords less
than 1 byte or greater than 10 bytes in length are not valid.
Please note that if password is not in EBCDIC, it must be
converted to EBCDIC uppercase.
2) XOR_PW = Padded_PW xor '5555555555555555'X
The padded password is Exclusive OR'ed with 8 bytes of '55'X.
3) SHIFT_RESULT = XOR_PW << 1
The entire 8-byte result is shifted 1 bit to the left; the left-
most bit value is discarded, and the rightmost bit value is
cleared to 0.
4) PW_TOKEN = DES_ECB_mode(SHIFT_RESULT, /* key */
userID_in_EBCDIC_uppercase /* data */ )
Murphy, et al. Informational [Page 13]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
This shifted result is used as key to the Data Encryption Standard
(Federal Information Processing Standards 46-2 [FIPS-46-2]) to
encipher the user identifier. When the user identifier is less
than 8 bytes, it is left justified in an 8-byte variable and
padded to the right with '40'X. When the user identifier is 9 or
10 bytes, it is first padded to the right with '40'X to a length
of 10 bytes. Then bytes 9 and 10 are "folded" into bytes 1-8
using the following algorithm:
Bit 0 is the high-order bit (i.e., has value of '80'X).
Byte 1, bits 0 and 1 are replaced with byte 1, bits 0 and 1
Exclusive OR'ed with byte 9, bits 0 and 1.
Byte 2, bits 0 and 1 are replaced with byte 2, bits 0 and 1
Exclusive OR'ed with byte 9, bits 2 and 3.
Byte 3, bits 0 and 1 are replaced with byte 3, bits 0 and 1
Exclusive OR'ed with byte 9, bits 4 and 5.
Byte 4, bits 0 and 1 are replaced with byte 4, bits 0 and 1
Exclusive OR'ed with byte 9, bits 6 and 7.
Byte 5, bits 0 and 1 are replaced with byte 5, bits 0 and 1
Exclusive OR'ed with byte 10, bits 0 and 1.
Byte 6, bits 0 and 1 are replaced with byte 6, bits 0 and 1
Exclusive OR'ed with byte 10, bits 2 and 3.
Byte 7, bits 0 and 1 are replaced with byte 7, bits 0 and 1
Exclusive OR'ed with byte 10, bits 4 and 5.
Byte 8, bits 0 and 1 are replaced with byte 8, bits 0 and 1
Exclusive OR'ed with byte 10, bits 6 and 7.
User identifiers greater than 10 bytes or less than 1 byte are not
the result of this encryption ID, known as PW_TOKEN in the paper.
5) Increment PWSEQs and store it.
Each LU must maintain a pair of sequence numbers for ATTACHs sent
and received on each session. Each time an ATTACH is generated,
(and password substitutes are in use on the session) the sending
sequence number, PWSEQs, is incremented and saved for the next
time. Both values are set to zero at BIND time. So the first use
of PWSEQs has the value of 1 and increases by one with each use.
A new field is added to the ATTACH to carry this sequence number.
However, in certain error conditions, it is possible for the
sending side to increment the sequence number, and the receiver
may not increment it. When the sender sends a subsequent ATTACH,
the receiver will detect a missing sequence. This is allowed.
However the sequence number received must always be larger than
the previous one, even if some are missing.
Murphy, et al. Informational [Page 14]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
The maximum number of consecutive missing sequence numbers allowed
is 16. If this is exceeded, the session is unbound with a
protocol violation.
Note: The sequence number must be incremented for every ATTACH
sent. However, the sequence number field is only required to be
included in the FMH5 if a password substitute is sent (byte 4, bit
3 on).
6) RDrSEQ = RDr + PWSEQs /* RDr is server seed. */
The current value of PWSEQs is added to RDr, the random value
received from the partner LU on this session, yielding RDrSEQ,
essentially a predictably modified value of the random value
received from the partner LU at BIND time.
7) PW_SUB = DES_CBC_mode(PW_TOKEN, /* key */
(RDrSEQ, /* 8 bytes */
RDs, /* 8 bytes */
ID xor RDrSEQ, /* 16 bytes */
PWSEQs, /* 8 bytes */
) /* data */
)
The PW_TOKEN is used as a key to the DES function to generate an
8-byte value for the following string of inputs. The DES CBC
mode Initialization Vector (IV) used is 8 bytes of '00'X.
RDrSEQ: the random data value received from the partner LU
plus the sequence number.
RDs: the random data value sent to the partner LU on BIND
for this session.
A 16-byte value created by:
- padding the user identifier with '40'X to a length
of 16 bytes.
- Exclusive OR'ing the two 8-byte halves of the padded
user identifier with the RDrSEQ value.
Note: User ID must first be converted to EBCDIC
uppercase.
PWSEQs: the sequence number.
Murphy, et al. Informational [Page 15]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
This is similar to the process used on LU-LU verification as
described in the Enhanced LU-LU Bind Security. The resulting
enciphered random data is the 'password substitute'.
8) Handling passwords of length 9 and 10
1. Generate PW_TOKENa by using characters 1 to 8 of the password
and steps 1-4 from the previous section.
2. Generate PW_TOKENb by using characters 9 and 10 and steps 1-4
from the previous section. In this case, Padded_PW from step 1
will be characters 9 and 10 padded to the right with '40'X, for
a total length of 8.
3. PW_TOKEN = PW_TOKENa xor PW_TOKENb
4. Now compute PW_SUB by performing steps 5-7 from the previous
section.
9) Example DES Password Substitute Calculation
ID: USER123
Password: ABCDEFG
Server seed: '7D4C2319F28004B2'X
Client seed: '08BEF662D851F4B1'X
PWSEQs: 1 (PWSEQs is a sequence number needed in the
7-step encryption, and it is always one)
DES Encrypted Password should be: '5A58BD50E4DD9B5F'X
5.2. Secure Hash Algorithm (SHA) Password Substitutes
A Network Station or Enhanced Client can generate SHA encrypted
passwords if it follows these steps.
1) Convert the user identifier to uppercase UNICODE format (if it is
not already in this format).
The user identifier must be left justified in a 10-byte variable
and padded to the right with '40'X up to a 10-byte length prior to
converting it to UNICODE. If the user's password is 10 bytes in
length, no padding will occur. User identifiers of less than 1
byte or greater than 10 bytes in length are not valid. The user
identifier will be 20 bytes in length after conversion to UNICODE,
so the variable that will hold the UNICODE user identifier should
have a length of 20 bytes.
Murphy, et al. Informational [Page 16]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
2) Ensure the password is in UNICODE format (if it is not already in
this format).
The user's password must be left justified in a 128-byte variable.
It does not need to be padded to the right with '40'X up to a
128-byte length. Passwords less than 1 byte or greater than 128
bytes in length are not valid. The password will be 2 times its
original length after conversion to UNICODE, so the maximum length
of the variable that will hold the UNICODE password is 256 bytes.
3) Create a 20-byte password token as follows:
PW_token = SHA-1(uppercase_unicode_userid, /* 20 bytes */
unicode_password) /* from 2 to 256 bytes */
The actual routine to be used to perform the SHA-1 processing is
dependent on the programming language being used. For example, if
using the Java language, then use the java.security class to
perform the actual SHA-1 processing.
The PW_token will be used in subsequent step to actually generate
the final substitute password.
4) Increment PWSEQs and store it.
5) Create the 20-byte substitute password as follows:
PW_SUB = SHA-1(PW_token, /* 20 bytes */
serverseed, /* 8 bytes */
clientseed, /* 8 bytes */
uppercase_unicode_userid, /* 20 bytes */
PWSEQ) /* 8 bytes */
The actual routine to be used to perform the SHA-1 processing is
dependent on the programming language being used. For example, if
using the Java language, then use the java.security class to
perform the actual SHA-1 processing.
6) Example SHA Password Substitute Calculation
ID: USER123
Password: AbCdEfGh123?+
Server seed: '3E3A71C78795E5F5'X
Client seed: 'B1C806D5D377D994'X
PWSEQs: 1 (PWSEQs is a sequence number needed in the
SHA encryption, and it is always one)
Murphy, et al. Informational [Page 17]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
SHA Encrypted Password should be:
'E7FAB5F034BEDA42E91F439DD07532A24140E3DD'X
6. Kerberos Services Ticket Automatic Sign-On Support
An iSeries Telnet server specific USERVAR defined below will contain
the complete Generic Security Services (GSS) token for use on the
iSeries. Enhanced Telnet clients will need to obtain the Kerberos
services ticket from a Key Distribution Center (KDC). Implementation
steps for acquiring the Kerberos services ticket will be limited to
the Microsoft Security Support Provider Interface (SSPI) example
below. For information on Kerberos services tickets, refer to your
Network Authentication Service (NAS) documentation.
The custom USERVAR defined is:
USERVAR VALUE EXAMPLE DESCRIPTION
--------- ------------- -------------------- -------------------
IBMTICKET binary(16384) 16384-byte hex field Kerberos services token
Several other USERVARs, as defined in Section 6, can be used along
with the IBMTICKET USERVAR to allow a user greater control over their
startup environment.
The custom USERVARs defined to accomplish this are:
USERVAR VALUE EXAMPLE DESCRIPTION
-------- ---------------- ---------------- -----------------
IBMCURLIB us-ascii char(x) QGPL Current library
IBMIMENU us-ascii char(x) MAIN Initial menu
IBMPROGRAM us-ascii char(x) QCMD Program to call
x - up to a maximum of 10 characters
If you use the IBMSENDCONFREC USERVAR, as described in Section 5,
with a value of YES along with the Kerberos ticket USERVARs described
above, you will receive a Startup Response Record that will contain a
response code informing your Telnet client of the success or failure
of the Kerberos validation attempt. See Section 11 for details on
the Startup Response Record.
The following Microsoft SSPI example illustrates how to get the
client security token, which contains the Kerberos services ticket.
Murphy, et al. Informational [Page 18]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
1) Get a handle to the user's credentials:
PSecurityFunctionTable pSSPI_;
CredHandle credHandle;
TimeStamp timeStamp;
ss = pSSPI_->AcquireCredentialsHandle(
NULL, // Principal
"Kerberos", // PackageName
SECPKG_CRED_OUTBOUND, // CredentialUse
NULL, // LogonID
NULL, // AuthData
NULL, // GetKeyFnc
NULL, // GetKeyArg
&credHandle, // CredHandle
&timeStamp); // ExpireTime
2) Initialize security context to "request delegation". Mutual
authentication is also requested, although it is not required and
may not be performed.
CtxtHandle newContext;
unsigned long contextAttr;
unsigned char token[16384] ;
unsigned long tokenLen = sizeof(token);
SecBuffer sbo = {tokenLen, SECBUFFER_TOKEN, token};
SecBufferDesc sbdo = {SECBUFFER_VERSION, 1, &sbo}
pSSPI_->InitializeSecurityContext(
&credHandle, // CredHandle
NULL, // Context
"krbsrv400/fullyqualifiedLowerCaseSystemName",
// ServicePrincipalName
ISC_REQ_CONNECTION|ISC_REQ_DELEGATE|ISC_REQ_MUTUAL_AUTH,
// ContextRequest
NULL, // Reserved
SECURITY_NATIVE_DREP, // DataRep
NULL, // Input
NULL, // Reserved
&newContext, // NewContext
&sbdo, // Output
&contextAttr, // ContextAttr
&timeStamp); // ExpireTime
3) Free the user credentials handle with FreeCredentialsHandle().
4) Send security token to Telnet Server (padded with escape
characters).
Murphy, et al. Informational [Page 19]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
The following illustrates the Kerberos Token Negotiation:
iSeries Telnet server Enhanced Telnet client
-------------------------- -------------------------------
IAC DO NEW-ENVIRON -->
<-- IAC WILL NEW-ENVIRON
IAC SB NEW-ENVIRON SEND
USERVAR "IBMRSEEDxxxxxxxx"
VAR USERVAR IAC SE -->
IAC SB NEW-ENVIRON IS
USERVAR "IBMTICKET" VALUE
"zzzzzzzz..."
<-- IAC SE
.
.
(other negotiations) .
In this example, "xxxxxxxx" is an 8-byte hexadecimal random server
seed, and "zzzzzzzz..." is the complete Kerberos services token. If
the Kerberos services token is not valid, then the sign-on panel is
not bypassed. It should be noted that for the Kerberos token a
random server seed is not needed, although it will be sent by the
Telnet Server.
Actual bytes transmitted in the above example are shown in hex below,
where the server seed is "7D3E488F18080404", and the Kerberos
services token starts with "DFB0402F22ABA3BA...". The complete
Kerberos services token is not shown here, as the length of the token
could be 16384 bytes and would make this document extremely large.
As described in Section 6, the client must escape and/or byte stuff
any Kerberos token bytes, which could be seen as a Telnet environment
option [RFC1572], specifically VAR, VALUE, ESC, and USERVAR.
iSeries Telnet server Enhanced Telnet client
-------------------------- -------------------------
FF FD 27 -->
<-- FF FB 27
FF FA 27 01 03 49 42 4D
52 53 45 45 44 7D 3E 48
8F 18 08 04 04 00 03 FF
F0 -->
FF FA 27 00 03 49 42 4D
54 49 43 48 45 54 01 DF
B0 40 2F 22 AB A3 BA...
<-- FF F0
Murphy, et al. Informational [Page 20]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
7. Device Name Collision Processing
Device name collision occurs when a Telnet client sends the Telnet
server a virtual device name that it wants to use, but that device is
already in use on the server. When this occurs, the Telnet server
sends a request to the client asking it to try another device name.
The environment option negotiation uses the USERVAR name of DEVNAME
to communicate the virtual device name. The following shows how the
Telnet server will request the Telnet client to send a different
DEVNAME when device name collision occurs.
iSeries Telnet server Enhanced Telnet client
-------------------------- -------------------------
IAC SB NEW-ENVIRON SEND
VAR USERVAR IAC SE -->
Server requests all environment variables be sent.
IAC SB NEW-ENVIRON IS USERVAR
"DEVNAME" VALUE "MYDEVICE1"
USERVAR "xxxxx" VALUE "xxx"
...
<-- IAC SE
Client sends all environment variables, including DEVNAME. Server
tries to select device MYDEVICE1. If the device is already in use,
server requests DEVNAME be sent again.
IAC SB NEW-ENVIRON SEND
USERVAR "DEVNAME" IAC SE -->
Server sends a request for a single environment variable: DEVNAME
IAC SB NEW-ENVIRON IS USERVAR
<-- "DEVNAME" VALUE "MYDEVICE2" IAC SE
Client sends one environment variable, calculating a new value of
MYDEVICE2. If MYDEVICE2 is different from the last request, then
server tries to select device MYDEVICE2, else server disconnects
client. If MYDEVICE2 is also in use, server will send DEVNAME
request again and keep doing so until it receives a device that is
not in use, or the same device name twice in row.
Murphy, et al. Informational [Page 21]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
8. Enhanced Printer Emulation Support
Telnet environment option USERVARs have been defined to allow a
compliant Telnet client more control over the Telnet server virtual
device on the iSeries. These USERVARs allow the client Telnet to
select a previously created virtual device or auto-create a new
virtual device with requested attributes.
This makes the enhancements available to any Telnet client that
chooses to support the new negotiations.
The USERVARs defined to accomplish this are:
USERVAR VALUE EXAMPLE DESCRIPTION
------------- ---------------- ---------------- -------------------
DEVNAME us-ascii char(x) PRINTER1 Printer device name
IBMIGCFEAT us-ascii char(6) 2424J0 IGC feature (DBCS)
IBMMSGQNAME us-ascii char(x) QSYSOPR *MSGQ name
IBMMSGQLIB us-ascii char(x) QSYS *MSGQ library
IBMFONT us-ascii char(x) 12 Font
IBMFORMFEED us-ascii char(1) C | U | A Formfeed
IBMTRANSFORM us-ascii char(1) 1 | 0 Transform
IBMMFRTYPMDL us-ascii char(x) *IBM42023 Mfg. type and model
IBMPPRSRC1 binary(1) 1-byte hex field Paper source 1
IBMPPRSRC2 binary(1) 1-byte hex field Paper source 2
IBMENVELOPE binary(1) 1-byte hex field Envelope hopper
IBMASCII899 us-ascii char(1) 1 | 0 ASCII 899 support
IBMWSCSTNAME us-ascii char(x) *NONE WSCST name
IBMWSCSTLIB us-ascii char(x) *LIBL WSCST library
x - up to a maximum of 10 characters
The "IBM" prefix on the USERVARs denotes iSeries-specific attributes.
The DEVNAME USERVAR is used for both displays and printers. The
IBMFONT and IBMASCII899 are used only for SBCS environments.
For a description of most of these parameters (drop the "IBM" from
the USERVAR) and their permissible values, refer to Chapter 8 in the
Communications Configuration Reference [COMM-CONFIG].
The IBMIGCFEAT supports the following variable DBCS language
identifiers in position 5 (positions 1-4 must be '2424'; position 6
must be '0'):
'J' = Japanese 'K' = Korean
'C' = Traditional Chinese 'S' = Simplified Chinese
Murphy, et al. Informational [Page 22]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
The IBMTRANSFORM and IBMASCII899 values correspond to:
'1' = Yes '0' = No
The IBMFORMFEED values correspond to:
'C' = Continuous 'U' = Cut 'A' = Autocut
The IBMPPRSRC1, IBMPPRSRC2, and IBMENVELOPE custom USERVARs do not
map directly to their descriptions in Chapter 8 in the Communications
Configuration Reference [COMM-CONFIG]. To map these, use the index
listed here:
IBMPPRSRC1 HEX IBMPPRSRC2 HEX IBMENVELOPE HEX
---------- ----- ---------- ----- ----------- -----
*NONE 'FF'X *NONE 'FF'X *NONE 'FF'X
*MFRTYPMDL '00'X *MFRTYPMDL '00'X *MFRTYPMDL '00'X
*LETTER '01'X *LETTER '01'X *B5 '06'X
*LEGAL '02'X *LEGAL '02'X *MONARCH '09'X
*EXECUTIVE '03'X *EXECUTIVE '03'X *NUMBER9 '0A'X
*A4 '04'X *A4 '04'X *NUMBER10 '0B'X
*A5 '05'X *A5 '05'X *C5 '0C'X
*B5 '06'X *B5 '06'X *DL '0D'X
*CONT80 '07'X *CONT80 '07'X
*CONT132 '08'X *CONT132 '08'X
*A3 '0E'X *A3 '0E'X
*B4 '0F'X *B4 '0F'X
*LEDGER '10'X *LEDGER '10'X
9. Telnet Printer Terminal Types
New Telnet options are defined for the printer pass-through mode of
operation. To enable printer pass-through mode, both the client and
server must agree to support at least the Transmit-Binary, End-Of-
Record, and Terminal-Type Telnet options. The following are new
terminal types for printers:
TERMINAL-TYPE DESCRIPTION
------------- -------------------
IBM-5553-B01 Double-Byte printer
IBM-3812-1 Single-Byte printer
Specific characteristics of the IBM-5553-B01 or IBM-3812-1 printers
are specified through the USERVAR IBMMFRTYPMDL, which specifies the
manufacturer type and model.
Murphy, et al. Informational [Page 23]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
An example of a typical negotiation process to establish printer
pass-through mode of operation is shown below. In this example, the
server initiates the negotiation by sending the DO TERMINAL-TYPE
request.
For DBCS environments, if IBMTRANSFORM is set to 1 (use Host Print
Transform), then the virtual device created is 3812, not 5553.
Therefore, IBM-3812-1 (and not IBM-5553-B01) should be negotiated for
TERMINAL-TYPE.
iSeries Telnet server Enhanced Telnet client
-------------------------- --------------------------
IAC DO NEW-ENVIRON -->
<-- IAC WILL NEW-ENVIRON
IAC SB NEW-ENVIRON SEND
VAR USERVAR IAC SE -->
IAC SB NEW-ENVIRON IS
USERVAR "DEVNAME" VALUE "PCPRINTER"
USERVAR "IBMMSGQNAME" VALUE "QSYSOPR"
USERVAR "IBMMSGQLIB" VALUE "*LIBL"
USERVAR "IBMTRANSFORM" VALUE "0"
USERVAR "IBMFONT" VALUE "12"
USERVAR "IBMFORMFEED" VALUE "C"
USERVAR "IBMPPRSRC1" VALUE ESC '01'X
USERVAR "IBMPPRSRC2" VALUE '04'X
USERVAR "IBMENVELOPE" VALUE IAC 'FF'X
<-- IAC SE
IAC DO TERMINAL-TYPE -->
<-- IAC WILL TERMINAL-TYPE
IAC SB TERMINAL-TYPE SEND
IAC SE -->
IAC SB TERMINAL-TYPE IS IBM-3812-1
<-- IAC SE
IAC DO BINARY -->
<-- IAC WILL BINARY
IAC DO EOR -->
<-- IAC WILL EOR
Some points about the above example. The IBMPPRSRC1 value requires
escaping the value using ESC according to Telnet environment options
[RFC1572]. The IBMPPRSRC2 does not require an ESC character since
'04'X has no conflict with environment options. Finally, to send
'FF'X for the IBMENVELOPE value, escape the 'FF'X value by using
another 'FF'X (called "doubling"), so as not to have the value
interpreted as a Telnet character per the Telnet protocol
specification [RFC854].
Murphy, et al. Informational [Page 24]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
Actual bytes transmitted in the above example are shown in hex below.
iSeries Telnet server Enhanced Telnet client
-------------------------- --------------------------
FF FD 27 -->
<-- FF FB 27
FF FA 27 01 00 03 FF F0 -->
FF FA 27 00 03 44 45 56
4E 41 4D 45 01 50 43 50
52 49 4E 54 45 52 03 49
42 4D 4D 53 47 51 4E 41
4D 45 01 51 53 59 53 4F
50 52 03 49 42 4D 4D 53
47 51 4C 49 42 01 2A 4C
49 42 4C 03 49 42 4D 54
52 41 4E 53 46 4F 52 4D
01 30 03 49 42 4D 46 4F
4E 54 01 31 32 03 49 42
4D 46 4F 52 4D 46 45 45
44 01 43 03 49 42 4D 50
50 52 53 52 43 31 01 02
01 03 49 42 4D 50 50 52
53 52 43 32 01 04 03 49
42 4D 45 4E 56 45 4C 4F
<-- 50 45 01 FF FF FF F0
FF FD 18 -->
<-- FF FB 18
FF FA 18 01 FF F0 -->
FF FA 18 00 49 42 4D 2D
<-- 33 38 31 32 2D 31 FF F0
FF FD 00 -->
<-- FF FB 00
FF FD 19 -->
FF FB 19
10. Startup Response Record for Printer and Display Devices
Once Telnet negotiation for a 5250 pass-through mode is completed,
the iSeries Telnet server will initiate a virtual device (printer or
display) power-on sequence on behalf of the Telnet client. The
Telnet server will supply a Startup Response Record to the Telnet
client with the status of the device power-on sequence, indicating
success or failure of the virtual device power-on sequence.
This section shows an example of two Startup Response Records. The
source device is a type 3812 model 01 printer with the name
"PCPRINTER" on the target system "TARGET".
Murphy, et al. Informational [Page 25]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
Figure 1 shows an example of a successful response; Figure 2 shows an
example of an error response.
10.1. Example of a Success Response Record
The response record in Figure 1 was sent by an iSeries at Release
V4R2. It is an example of the target sending back a successful
Startup Response Record.
+------------------------------------------------------------------+
| +----- Pass-Through header |
| | +--- Response data |
| | | +---- Start diagnostic information|
| | | | |
| +----------++----------++--------------------------------------- |
| | || || |
| 004912A090000560060020C0003D0000C9F9F0F2E3C1D9C7C5E34040D7C3D7D9 |
| | | T A R G E T P C P R |
| +------+ |
| Response Code (I902) |
| |
| ---------------------------------------------------------------- |
| |
| C9D5E3C5D9400000000000000000000000000000000000000000000000000000 |
| I N T E R |
| |
| +------- End of diagnostic information |
| | |
| -----------------+ |
| | |
| 000000000000000000 |
+------------------------------------------------------------------+
Figure 1. Example of a success response record
- '0049'X = Length pass-through data, including this length field
- '12A0'X = GDS LU6.2 header
- '90000560060020C0003D0000'X = Fixed value fields
- 'C9F9F0F2'X = Response Code (I902)
- 'E3C1D9C7C5E34040'X = System Name (TARGET)
- 'D7C3D7D9C9D5E3C5D940'X = Object Name (PCPRINTER)
Murphy, et al. Informational [Page 26]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
10.2. Example of an Error Response Record
The response record in Figure 2 is one that reports an error. The
virtual device named "PCPRINTER" is not available on the target
system "TARGET" because the device is not available. You would
normally see this error if the printer were already assigned to
another Telnet session.
+------------------------------------------------------------------+
| +----- Pass-Through header |
| | +--- Response data |
| | | +---- Start diagnostic information|
| | | | |
| +----------++----------++--------------------------------------- |
| | || || |
| 004912A09000056006008200003D0000F8F9F0F2E3C1D9C7C5E34040D7C3D7D9 |
| | | T A R G E T P C P R |
| +------+ |
| Response Code (8902) |
| |
| ---------------------------------------------------------------- |
| |
| C9D5E3C5D9400000000000000000000000000000000000000000000000000000 |
| I N T E R |
| |
| +------- End of diagnostic information |
| | |
| -----------------+ |
| | |
| 000000000000000000 |
+------------------------------------------------------------------+
Figure 2. Example of an error response record
- '0049'X = Length pass-through data, including this length field
- '12A0'X = GDS LU6.2 header
- '90000560060020C0003D0000'X = Fixed value fields
- 'F8F9F0F2'X = Response Code (8902)
- 'E3C1D9C7C5E34040'X = System Name (TARGET)
- 'D7C3D7D9C9D5E3C5D940'X = Object Name (PCPRINTER)
Murphy, et al. Informational [Page 27]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
10.3. Example of a Response Record with Device Name Retry
The Response Record can be used in conjunction with the DEVNAME
Environment variable to allow client emulators to inform users of
connection failures. In addition, this combination could be used by
client emulators that accept multiple device names to try on session
connections. The client would be able to walk through a list of
possible device names and provide feedback based on the response
code(s) received for each device name that was rejected.
The following sequence shows a negotiation between the client and the
server in which a named device "RFCTEST" is requested by the client.
The device name is already assigned to an existing condition. The
server responds with the Response Record showing an 8902 response
code. The client could use this information to inform the user that
the device name just tried was already in use. Following the
Response Record the server would then invite the client to try
another device name. Because the same device name was used again by
the client, the server closed the session.
Murphy, et al. Informational [Page 28]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
iSeries Telnet server Enhanced Telnet client
-------------------------- -------------------------
IAC DO NEW-ENVIRON -->
<-- IAC WILL NEW-ENVIRON
IAC DO TERMINAL-TYPE -->
<-- IAC WILL TERMINAL-TYPE
IAC SB NEW-ENVIRON SEND
USERVAR "IBMRSEEDxxxxxxxx"
VAR USERVAR IAC SE -->
IAC SB NEW-ENVIRON IS
USERVAR "DEVNAME"
VALUE "RFCTEST"
USERVAR "IBMSENDCONFREC"
VALUE "YES"
<-- IAC SE
IAC SB TERMINAL-TYPE SEND
IAC SE -->
IAC SB TERMINAL-TYPE IS
<-- IBM-3180-2 IAC SE
(terminal type negotiations
completed)
IAC DO EOR -->
<-- IAC WILL EOR
IAC WILL EOR -->
<-- IAC DO EOR
IAC DO BINARY -->
<-- IAC WILL BINARY
IAC WILL BINARY -->
<-- IAC DO BINARY
(73 BYTE RFC 1205 RECORD
WITH 8902 ERROR CODE) -->
IAC SB NEW-ENVIRON SEND
USERVAR "DEVNAME"
IAC SE -->
IAC SB NEW-ENVIRON IS
USERVAR "DEVNAME"
VALUE "RFCTEST"
USERVAR "IBMSENDCONFREC"
VALUE "YES"
<-- IAC SE
(server closes connection)
Murphy, et al. Informational [Page 29]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
Actual bytes transmitted in the above example are shown in hex below.
iSeries Telnet server Enhanced Telnet client
-------------------------- --------------------------
FF FD 27 -->
<-- FF FB 27
FF FD 18 -->
<-- FF FB 18
FF FA 27 01 03 49 42 4D
52 53 45 45 44 C4 96 67
76 9A 23 E3 34 00 03 FF
F0 -->
FF FA 27 00 03 44 45 56
4E 41 4D 45 01 52 46 43
54 45 53 54 03 49 42 4D
53 45 4E 44 43 4F 4E 46
52 45 43 01 59 45 53 FF
<-- F0
FF FA 18 01 FF F0 -->
<-- FF FA 18 00 49 42 4D 2D
33 31 38 30 2D 32 FF F0
FF FD 19 -->
<-- FF FB 19
FF FB 19 -->
<-- FF FD 19
FF FD 00 -->
<-- FF FB 00
FF FB 00 -->
<-- FF FD 00
00 49 12 A0 90 00 05 60
06 00 20 C0 00 3D 00 00
F8 F9 F0 F2 D9 E2 F0 F3
F5 40 40 40 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 FF EF -->
FF FA 27 01 03 44 45 56
4E 41 4D 45 FF F0 -->
<-- FF FA 27 00 03 44 45 56
4E 41 4D 45 01 52 46 43
54 45 53 54 03 49 42 4D
53 45 4E 44 43 4F 4E 46
52 45 43 01 59 45 53 FF
F0
Murphy, et al. Informational [Page 30]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
10.4. Response Codes
The Start-Up Response Record success response codes:
CODE DESCRIPTION
---- ------------------------------------------------------
I901 Virtual device has less function than source device.
I902 Session successfully started.
I906 Automatic sign-on requested, but not allowed.
Session still allowed; a sign-on screen will be
coming.
The Start-Up Response Record error response codes:
CODE DESCRIPTION
---- ------------------------------------------------------
2702 Device description not found.
2703 Controller description not found.
2777 Damaged device description.
8901 Device not varied on.
8902 Device not available.
8903 Device not valid for session.
8906 Session initiation failed.
8907 Session failure.
8910 Controller not valid for session.
8916 No matching device found.
8917 Not authorized to object.
8918 Job canceled.
8920 Object partially damaged.
8921 Communications error.
8922 Negative response received.
8923 Start-up record built incorrectly.
8925 Creation of device failed.
8928 Change of device failed.
8929 Vary on or vary off failed.
8930 Message queue does not exist.
8934 Start-up for S/36 WSF received.
8935 Session rejected.
8936 Security failure on session attempt.
8937 Automatic sign-on rejected.
8940 Automatic configuration failed or not allowed.
I904 Source system at incompatible release.
Murphy, et al. Informational [Page 31]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
The Start-Up Response Record error response codes for non-Kerberos
Services Token automatic sign-on:
CODE DESCRIPTION
---- ------------------------------------------------------
0001 System error.
0002 Userid unknown.
0003 Userid disabled.
0004 Invalid password/passphrase/token.
0005 Password/passphrase/token is expired.
0006 Pre-V2R2 password.
0008 Next invalid password/passphrase/token will revoke userid.
The Start-Up Response Record error response codes for Kerberos
Services Token automatic sign-on support:
CODE DESCRIPTION
---- ------------------------------------------------------
0001 User profile is disabled.
0002 Kerberos principal maps to a system user profile.
0003 Enterprise Identity Map (EIM) configuration error.
0004 EIM does not map Kerberos principal to user profile.
0005 EIM maps Kerberos principal to multiple user profiles.
0006 EIM maps Kerberos principal to user profile not found on
system.
1000 None of the requested mechanisms are supported by the
local system.
2000 The input name is not formatted properly or is not valid.
6000 The received input token contains an incorrect signature.
7000 No credentials available or credentials valid for context
init only.
9000 Consistency checks performed on the input token failed.
A000 Consistency checks on the cred structure failed.
B000 Credentials are no longer valid.
D000 The runtime failed for reasons that are not defined at the
GSS level.
In the case where the USERVAR, DEVNAME USERVAR, IBMSENDCONFREC
USERVAR, IBMSUBSPW USERVAR, and IBMRSEED USERVAR are all used
together, any device errors will take precedence over automatic
sign-on errors. That is:
1) If the requested named device is not available or an error occurs
when attempting to create the device on the server system, a
device related return code (i.e., 8902) will be sent to the client
system in the display confirmation record.
Murphy, et al. Informational [Page 32]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
2) If the requested named device is available or no errors occur when
attempting to create the device on the server system, an automatic
sign-on return code (i.e., 0002) will be sent to the client system
in the display confirmation record.
11. Printer Steady-State Pass-Through Interface
The information in this section applies to the pass-through session
after the receipt of startup confirmation records is complete.
Following is the printer header interface used by Telnet.
+------------------------------------------------------------------+
| +-- Length of structure (LLLL) |
| | |
| | +-- GDS identifier |
| | | |
| | | +-- Data flow record |
| | | | |
| | | | +-- Length of pass-through specific header (LL) |
| | | | | |
| | | | | +-- Flags |
| | | | | | |
| | | | | | +-- Printer operation code |
| | | | | | | |
| | | | | | | +-- Diagnostic field - zero pad to|
| | | | | | | | LL specified |
| | | | | | | | |
| | | | | | | | +-- Printer data |
| | | | | | | | | |
| +--+ +--+ +--+ ++ +--+ ++ +----------+ +----------------+ |
| | | | | | | || | | || | | | | |
| xxxx 12A0 xxxx xx xxxx xx xxxxxxxxxxxx ... print data ... |
| |
+------------------------------------------------------------------+
Figure 3. Layout of the printer pass-through header
BYTES 0-1: Length of structure including this field (LLLL)
BYTES 2-3: GDS Identifier ('12A0'X)
BYTE 4-5: Data flow record
This field contains flags that describe what type of
data pass-through should be expected to be found
following this header. Generally, bits 0-2 in the first
byte are mutually exclusive (that is, if one of them is
Murphy, et al. Informational [Page 33]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
set to '1'B, the rest will be set to '0'B.) The bits and
their meanings follow.
BIT DESCRIPTION
0 Start-Up confirmation
1 Termination record
2 Start-Up Record
3 Diagnostic information included
4 - 5 Reserved
6 Reserved
7 Printer record
8 - 13 Reserved
14 Client-originated (inbound) printer record
15 Server-originated (outbound) printer record
BYTE 6: Length printer pass-through header including this field
(LL)
BYTES 7-8: Flags
BYTE 7 BITS: xxxx x111 --> Reserved
xxxx 1xxx --> Last of chain
xxx1 xxxx --> First of chain
xx1x xxxx --> Printer now ready
x1xx xxxx --> Intervention Required
1xxx xxxx --> Error Indicator
BYTE 8 BITS: xxxx xxxx --> Reserved
BYTE 9: Printer operation code
'01'X Print/Print complete
'02'X Clear Print Buffers
BYTE 10-LL: Diagnostic information (Note 1)
If BYTE 7 = xx1x xxxx, then bytes 10-LL may contain:
Printer ready C9 00 00 00 02
If BYTE 7 = x1xx xxxx, then bytes 10-LL may contain: (Note 2)
Command/parameter not valid C9 00 03 02 2x
Print check C9 00 03 02 3x
Forms check C9 00 03 02 4x
Normal periodic condition C9 00 03 02 5x
Data stream error C9 00 03 02 6x
Machine/print/ribbon check C9 00 03 02 8x
Murphy, et al. Informational [Page 34]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
If BYTE 7 = 1xxx xxxx, then bytes 10-LL may contain: (Note 3)
Cancel 08 11 02 00
Invalid print parameter 08 11 02 29
Invalid print command 08 11 02 28
Diagnostic information notes:
1. LL is the length of the structure defined in Byte 6. If no
additional data is present, the remainder of the structure must
be padded with zeroes.
2. These are printer SIGNAL commands. Further information on these
commands may be obtained from the 5494 Remote Control Unit
Functions Reference guide [5494-CU]. Refer to your iSeries
printer documentation for more specific information on these data
stream exceptions. The following are some 3812 and 5553 errors
that may be seen:
Machine check C9 00 03 02 11
Graphics check C9 00 03 02 26
Print check C9 00 03 02 31
Form jam C9 00 03 02 41
Paper jam C9 00 03 02 47
End of forms C9 00 03 02 50
Printer not ready C9 00 03 02 51
Data stream - class 1 C9 00 03 02 66 loss of text
Data stream - class 2 C9 00 03 02 67 text appearance
Data stream - class 3 C9 00 03 02 68 multibyte control error
Data stream - class 4 C9 00 03 02 69 multibyte control parm
Cover unexpectedly open C9 00 03 02 81
Machine check C9 00 03 02 86
Machine check C9 00 03 02 87
Ribbon check C9 00 03 02 88
3. These are printer negative responses. Further information on
these commands may be obtained from the 5494 Remote Control Unit
Functions Reference guide [5494-CU].
The print data will start in byte LL+1.
11.1. Example of a Print Record
Figure 4 shows the server sending the client data with a print
record. This is normally seen following receipt of a Success
Response Record, such as the example in Figure 1.
Murphy, et al. Informational [Page 35]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
+--------------------------------------------------------------------+
| +-- Length of structure (LLLL) |
| | +-- GDS identifier |
| | | +-- Data flow record |
| | | | +-- Length of pass-through specific header (LL) |
| | | | | +-- Flags |
| | | | | | +-- Printer operation code |
| | | | | | | +-- Zero pad to LL specified (0A) |
| | | | | | | | +-- Printer data |
| | | | | | | | | |
| +--+ +--+ +--+ ++ +--+ ++ +----------+ +---------------------------|
| | | | | | | || | | || | | | |
| 0085 12A0 0101 0A 1800 01 000000000000 34C4012BD20345FF2BD2044C0002|
| |
| ------------------------------------------------------------ |
| |
| 2BD2040D00002BD20A8501010201030204022BD20309022BD2061100014A |
| |
| ------------------------------------------------------------ |
| |
| 402BD20601010000012BD306F60000FFFF2BD20A48000001000000010100 |
| |
| ------------------------------------------------------------ |
| |
| 2BD10705000B0090012BD2044900F02BD206404A403DE02BD2041500F034 |
| |
| end of printer data |
| -------------------------+ |
| | |
| C4012BD10381FF002BC8034001 |
+--------------------------------------------------------------------+
Figure 4. Server sending client data with a print record
- '0085'X = Logical record length, including this byte (LLLL)
- '12A0'X = GDS LU6.2 header
- '0101'X = Data flow record (server to client)
- '0A'X = Length of pass-through specific header (LL)
- '1800'X = First of chain / Last of chain indicators
- '01'X = Print
- '000000000000'X = Zero pad header to LL specified
- '34C401'X = First piece of data for spooled data
- Remainder is printer data/commands/orders
Murphy, et al. Informational [Page 36]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
11.2. Example of a Print Complete Record
Figure 5 shows the client sending the server a print complete record.
This would normally follow receipt of a print record, such as the
example in Figure 4. This indicates successful completion of a print
request.
+-------------------------------------------------------------------+
| +-- Length of structure (LLLL) |
| | +-- GDS identifier |
| | | +-- Data flow record |
| | | | +-- Length of pass-through specific header (LL) |
| | | | | +-- Flags |
| | | | | | +-- Printer operation code |
| | | | | | | |
| +--+ +--+ +--+ ++ +--+ ++ |
| | | | | | | || | | || |
| 000A 12A0 0102 04 0000 01 |
+-------------------------------------------------------------------+
Figure 5. Client sending server a print complete record
- '000A'X = Logical record length, including this byte (LLLL)
- '12A0'X = GDS LU6.2 header
- '0102'X = Data flow response record (client to server)
- '04'X = Length of pass-through specific header (LL)
- '0000'X = Good Response
- '01'X = Print Complete
11.3. Example of a Null Print Record
Figure 6 shows the server sending the client a null print record.
The null print record is the last print command the server sends to
the client for a print job, and it indicates to the printer that
there is no more data. The null data byte '00'X is optional and in
some cases may be omitted (in particular, this scenario occurs in
DBCS print streams).
This example would normally follow any number of print records, such
as the example in Figure 4. This indicates successful completion of
a print job. The client normally responds to this null print record
with another print complete record, such as in Figure 5.
Murphy, et al. Informational [Page 37]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
+------------------------------------------------------------------+
| +-- Length of structure (LLLL) |
| | +-- GDS identifier |
| | | +-- Data flow record |
| | | | +-- Length of pass-through specific header (LL) |
| | | | | +-- Flags |
| | | | | | +-- Printer operation code |
| | | | | | | +-- Zero pad to LL specified (0A) |
| | | | | | | | +-- Printer data |
| | | | | | | | | |
| +--+ +--+ +--+ ++ +--+ ++ +----------+ ++ |
| | | | | | | || | | || | | || |
| 0011 12A0 0101 0A 0800 01 000000000000 00 |
+------------------------------------------------------------------+
Figure 6. Server sending client a null print record
- '0011'X = Logical record length, including this byte
- '12A0'X = GDS LU6.2 header
- '0101'X = Data flow record
- '0A'X = Length of pass-through specific header (LL)
- '0800'X = Last of Chain
- '01'X = Print
- '000000000000'X = Zero pad header to LL specified
- '00'X = Null data byte
Murphy, et al. Informational [Page 38]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
12. End-to-End Print Example
The next example shows a full print exchange between a Telnet client
and server for a 526 byte spooled file. Selective translation of the
hexadecimal streams into 1) Telnet negotiations and 2) ASCII/EBCDIC
characters is done to aid readability. Telnet negotiations are
delimited by '(' and ')' parenthesis characters; ASCII/EBCDIC
conversions are bracketed by '|' vertical bar characters.
iSeries Telnet server Enhanced Telnet client
------------------------------- ---------------------------------
FFFD27 -->
(IAC DO NEW-ENVIRON)
<-- FFFB27
(IAC WILL NEW-ENVIRON)
FFFD18FFFA270103 49424D5253454544
7EA5DFDDFD300404 0003FFF0 -->
(IAC DO TERMINAL-TYPE
IAC SB NEW-ENVIRON SEND USERVAR
IBMRSEED xxxxxxxx VAR USERVAR
IAC SE)
<-- FFFB18
(IAC WILL TERMINAL-TYPE)
FFFA1801FFF0 -->
(IAC SB TERMINAL-TYPE SEND IAC
SE)
FFFA27000349424D 52534545447EA5DF
DDFD300404000344 45564E414D450144
554D4D5950525403 49424D4D5347514E
414D450151535953 4F50520349424D4D
5347514C4942012A 4C49424C0349424D
464F4E5401313103 49424D5452414E53
464F524D01310349 424D4D4652545950
4D444C012A485049 490349424D505052
5352433101020103 49424D5050525352
433201040349424D 454E56454C4F5045
01FFFF0349424D41 5343494938393901
<-- 30FFF0
Murphy, et al. Informational [Page 39]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
(IAC SB NEW-ENVIRON IS USERVAR
IBMRSEED xxxxxxxx VAR
USERVAR DEVNAME VALUE DUMMYPRT
USERVAR IBMMSGQNAME VALUE
QSYSOPR
USERVAR IBMMSGQLIB VALUE *LIBL
USERVAR IBMFONT VALUE 11
USERVAR IBMTRANSFORM VALUE 1
USERVAR IBMMFRTYPMDL VALUE *HPII
USERVAR IBMPPRSRC1 VALUE
ESC '01'X
USERVAR IBMPPRSRC2 VALUE '04'X
USERVAR IBMENVELOPE VALUE IAC
USERVAR IBMASCII899 VALUE 0
IAC SE)
<-- FFFA180049424D2D 333831322D31FFF0
(IAC SB TERMINAL-TYPE IS
IBM-3812-1 IAC SE)
FFFD19 -->
(IAC DO EOR)
<-- FFFB19
(IAC WILL EOR)
FFFB19 -->
(IAC WILL EOR)
<-- FFFD19
(IAC DO EOR)
FFFD00 -->
(IAC DO BINARY)
<-- FFFB00
(IAC WILL BINARY)
FFFB00 -->
(IAC WILL BINARY)
<-- FFFD00
(IAC DO BINARY)
Murphy, et al. Informational [Page 40]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
004912A090000560 060020C0003D0000 | - { |
C9F9F0F2C5D3C3D9 E3D7F0F6C4E4D4D4 |I902ELCRTP06DUMM| (EBCDIC)
E8D7D9E340400000 0000000000000000 |YPRT |
0000000000000000 0000000000000000 | |
0000000000000000 00FFEF --> | |
(73-byte startup success response
record ... IAC EOR)
00DF12A001010A18 0001000000000000 | |
03CD1B451B283130 551B287330703130 | E (10U (s0p10| (ASCII)
2E30306831327630 733062303033541B |.00h12v0s0b003T |
287330421B266440 1B266C304F1B266C |(s0B &d@ &l0O &l|
303038431B266C30 3035431B28733070 |008C &l005C (s0p|
31372E3130683130 7630733062303030 |17.10h10v0s0b000|
541B283130551B28 73307031372E3130 |T (10U (s0p17.10|
6831307630733062 303030541B287330 |h10v0s0b000T (s0|
421B2664401B266C 314F1B266C303035 |B &d@ &l1O &l005|
431B287330703137 2E31306831307630 |C (s0p17.10h10v0|
733062303030541B 266C314F1B287330 |s0b000T &l1O (s0|
7031372E31306831 3076307330623030 |p17.10h10v0s0b00|
30541B2873307031 372E313068313076 |0T (s0p17.10h10v|
3073306230303054 1B266C30303543FF |0s0b000T &l005C |
EF --> | |
(... 223-byte print record ...
... first of chain ...
... last of chain ... IAC EOR)
<-- 000A12A001020400 0001FFEF
(10-byte print complete header)
031012A001010A10 0001000000000000 | |
03FFFF1B451B2831 30551B2873307031 | E (10U (s0p1| (ASCII)
372E313068313076 3073306230303054 |7.10h10v0s0b000T|
1B287330421B2664 401B266C314F1B26 | (s0B &d@ &l1O &|
6C303035431B266C 31481B266C314F1B |l005C &l1H &l1O |
266C3032411B266C 31431B266C303030 |&l02A &l1C &l000|
38451B266C303038 431B266C30303439 |8E &l008C &l0049|
461B266130521B26 6C303035430A0A0A |F &a0R &l005C |
0A0A0A0A1B26612B 3030303130561B26 | &a+00010V &|
6C303035431B2661 2B30303231364820 |l005C &a+00216H |
2020202020202020 2020202020202020 | |
2020202020205072 696E74204B657920 | Print Key |
4F75747075742020 2020202020202020 |Output |
2020202020202020 2020202020202020 | |
2020202020205061 6765202020310D0A | Page 1 |
1B26612B30303231 3648202020203537 | &a+00216H 57|
3639535331205634 52334D3020393830 |69SS1 V4R3M0 980|
373203FFFF392020 2020202020202020 |72 9 |
Murphy, et al. Informational [Page 41]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
202020202020454C 4352545030362020 | ELCRTP06 |
2020202020202020 202030332F33312F | 03/31/|
3939202031363A33 303A34350D0A1B26 |99 16:30:45 &|
612B303032313648 0D0A1B26612B3030 |a+00216H &a+00|
3231364820202020 446973706C617920 |216H Display |
4465766963652020 2E202E202E202E20 |Device . . . . |
2E203A2020515041 444556303033510D |. : QPADEV003Q |
0A1B26612B303032 3136482020202055 | &a+00216H U|
73657220202E202E 202E202E202E202E |ser . . . . . .|
202E202E202E202E 203A202052434153 | . . . . : RCAS|
54524F0D0A1B2661 2B3030323136480D |TRO &a+00216H |
0A1B26612B303032 313648204D41494E | &a+00216H MAIN|
2020202020202020 2020202020202020 | |
2020202020202020 20202041532F3430 | AS/40|
30204D61696E204D 656E750D0A1B2661 |0 Main Menu &a|
2B30303203FFFF31 3648202020202020 |+002 16H |
2020202020202020 2020202020202020 | |
2020202020202020 2020202020202020 | |
2020202020202020 2020202020202020 | |
2020202020202053 797374656D3A2020 | System: |
20454C4352545030 360D0A1B26612B30 | ELCRTP06 &a+0|
3032313648205365 6C656374206F6E65 |0216H Select one|
206F662074686520 666F6C6C6F77696E | of the followin|
673A0D0A1B26612B 3030323136480D0A |g: &a+00216H |
1B26612B30303231 3648202020202020 | &a+00216H |
312E205573657220 7461736B730D0A1B |1. User tasks |
26612B3030323136 4820202020202032 |&a+00216H 2|
2E204F6666696365 207461736B730D0A |. Office tasks |
1B26612B30303231 36480D0A1B26612B | &a+00216H &a+|
3030323136482020 20202020342E2046 |00216H 4. F|
696C65732C206C69 627261726965732C |iles, libraries,|
20616EFFEF | an |
(... 784-byte print record ...
... first of chain ... IAC EOR)
<-- 000A12A001020400 0001FFEF
(10-byte print complete header)
020312A001010A00 0001000000000000 | |
64206603FFFF6F6C 646572730D0A1B26 |d f olders &| (ASCII)
612B303032313648 0D0A1B26612B3030 |a+00216H &a+00|
3231364820202020 2020362E20436F6D |216H 6. Com|
6D756E6963617469 6F6E730D0A1B2661 |munications &a|
2B3030323136480D 0A1B26612B303032 |+00216H &a+002|
3136482020202020 20382E2050726F62 |16H 8. Prob|
6C656D2068616E64 6C696E670D0A1B26 |lem handling &|
612B303032313648 202020202020392E |a+00216H 9.|
Murphy, et al. Informational [Page 42]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
20446973706C6179 2061206D656E750D | Display a menu |
0A1B26612B303032 3136482020202020 | &a+00216H |
31302E20496E666F 726D6174696F6E20 |10. Information |
417373697374616E 74206F7074696F6E |Assistant option|
730D0A1B26612B30 3032313648202020 |s &a+00216H |
202031312E20436C 69656E7420416363 | 11. Client Acc|
6573732F34303020 7461736B730D0A1B |ess/400 tasks |
26612B3030323136 480D0A1B26612B30 |&a+00216H &a+0|
303231364803ED20 2020202039302E20 |0216H 90. |
5369676E206F6666 0D0A1B26612B3030 |Sign off &a+00|
323136480D0A1B26 612B303032313648 |216H &a+00216H|
2053656C65637469 6F6E206F7220636F | Selection or co|
6D6D616E640D0A1B 26612B3030323136 |mmand &a+00216|
48203D3D3D3E0D0A 1B26612B30303231 |H ===> &a+0021|
36480D0A1B26612B 3030323136482046 |6H &a+00216H F|
333D457869742020 2046343D50726F6D |3=Exit F4=Prom|
707420202046393D 5265747269657665 |pt F9=Retrieve|
2020204631323D43 616E63656C202020 | F12=Cancel |
4631333D496E666F 726D6174696F6E20 |F13=Information |
417373697374616E 740D0A1B26612B30 |Assistant &a+0|
3032313648204632 333D53657420696E |0216H F23=Set in|
697469616C206D65 6E750D0A1B26612B |itial menu &a+|
3030323136480D0A 1B26612B30303231 |00216H &a+0021|
36480D0CFFEF |6H |
(... 515-byte print record ...
IAC EOR)
<-- 000A12A001020400 0001FFEF
(10-byte print complete header)
001412A001010A00 0001000000000000 | |
03021B45FFEF | E | (ASCII)
(... 20-byte print record ...
IAC EOR)
<-- 000A12A001020400 0001FFEF
(10-byte print complete header)
001112A001010A08 0001000000000000
00FFEF -->
(... 17-byte NULL print record ...
... last of chain ... IAC EOR)
<-- 000A12A001020400 0001FFEF
(10-byte print complete header)
Murphy, et al. Informational [Page 43]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
13. Security Considerations
The auto-sign-on feature provided by this RFC describes a way to
encrypt your login password. However, while passwords can now be
encrypted by using the IBMRSEED and IBMSUBSPW USERVAR negotiations,
users should understand that only the login passwords are encrypted
and not the entire Telnet session. Encryption of the Telnet session
requires that another protocol layer, such as SSL, be added.
The auto-sign-on feature supports plain text passwords, encrypted
passwords, and Kerberos tokens. However, using plain text passwords
is strongly discouraged. iSeries system administrators may want to
configure their systems to reject plain text passwords.
14. IANA Considerations
IANA registered the terminal types "IBM-3812-1" and "IBM-5553-B01" as
a terminal type [RFC1091]. They are used when communicating with
iSeries Telnet servers.
15. Normative References
[RFC854] Postel, J. and J. Reynolds, "Telnet Protocol
Specification", STD 8, RFC 854, May 1983.
[RFC855] Postel, J. and J. Reynolds, "Telnet Option
Specifications", STD 8, RFC 855, May 1983.
[RFC1091] VanBokkelen, J., "Telnet terminal-type option", RFC
1091, February 1989.
[RFC1205] Chmielewski, P., "5250 Telnet Interface", RFC 1205,
February 1991.
[RFC1572] Alexander, S., "Telnet Environment Option", RFC 1572,
January 1994.
[RFC2877] Murphy, T., Jr., Rieth, P., and J. Stevens, "5250
Telnet Enhancements", RFC 2877, July 2000.
16. Informative References
[RFC856] Postel, J. and J. Reynolds, "Telnet Binary
Transmission", STD 27, RFC 856, May 1983.
[RFC858] Postel, J. and J. Reynolds, "Telnet Supress Go Ahead
Option", STD 29, RFC 858, May 1983.
Murphy, et al. Informational [Page 44]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
[RFC885] Postel, J., "Telnet end of record option", RFC 885,
December 1983.
[5494-CU] IBM, "5494 Remote Control Unit, Functions Reference",
SC30-3533-04, August 1995.
[SYSTEM-API] IBM, "AS/400 System API Reference", SC41-5801-01,
February 1998.
[COMM-CONFIG] IBM, "AS/400 Communications Configuration",
SC41-5401-00, August 1997.
[NLS-SUPPORT] IBM, "AS/400 National Language Support", SC41-5101-01,
February 1998.
[FIPS-46-2] Data Encryption Standard (DES), Federal Information
Processing Standards Publication 46-2, January 22,
1988.
[FIPS-81] DES Modes of Operation, Federal Information Processing
Standards Publication 81, December 1980.
[FIPS-180-1] Secure Hash Standard, Federal Information Processing
Standards Publication 180-1, May 11, 1993.
17. Relation to Other RFCs
This RFC relies on the 5250 Telnet Interface [RFC1205] in all
examples.
This RFC replaces 5250 Telnet Enhancements [RFC2877], adding new
sections for Kerberos, SHA-1, security and IANA considerations.
Minor corrections and additional examples were also added.
Informative references have been removed.
Murphy, et al. Informational [Page 45]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
Authors' Addresses
Thomas E. Murphy, Jr.
IBM Corporation
2455 South Road
Poughkeepsie, NY 12601
Phone: (845) 435-7063
Fax: (845) 432-9414
EMail: murphyte@us.ibm.com
Paul F. Rieth
IBM Corporation
3605 Highway 52 North
Rochester, MN 55901
Phone: (507) 253-5218
Fax: (507) 253-5156
EMail: rieth@us.ibm.com
Jeffrey S. Stevens
IBM Corporation
3605 Highway 52 North
Rochester, MN 55901
Phone: (507) 253-5337
Fax: (507) 253-5156
EMail: jssteven@us.ibm.com
Murphy, et al. Informational [Page 46]
RFC 4777 IBM's iSeries Telnet Enhancements November 2006
Full Copyright Statement
Copyright (C) The IETF Trust (2006).
This document is subject to the rights, licenses and restrictions
contained in BCP 78 and at www.rfc-editor.org/copyright.html, and
except as set forth therein, the authors retain all their rights.
This document and the information contained herein are provided on an
"AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY, THE IETF TRUST,
AND THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT
THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
Intellectual Property
The IETF takes no position regarding the validity or scope of any
Intellectual Property Rights or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; nor does it represent that it has
made any independent effort to identify any such rights. Information
on the procedures with respect to rights in RFC documents can be
found in BCP 78 and BCP 79.
Copies of IPR disclosures made to the IETF Secretariat and any
assurances of licenses to be made available, or the result of an
attempt made to obtain a general license or permission for the use of
such proprietary rights by implementers or users of this
specification can be obtained from the IETF on-line IPR repository at
http://www.ietf.org/ipr.
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights that may cover technology that may be required to implement
this standard. Please address the information to the IETF at
ietf-ipr@ietf.org.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.
Murphy, et al. Informational [Page 47]