<- RFC Index (4801..4900)
RFC 4836
Obsoletes RFC 3636
Network Working Group E. Beili
Request for Comments: 4836 Actelis Networks
Obsoletes: 3636 April 2007
Category: Standards Track
Definitions of Managed Objects for
IEEE 802.3 Medium Attachment Units (MAUs)
Status of This Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Copyright Notice
Copyright (C) The IETF Trust (2007).
Abstract
This document defines a portion of the Management Information Base
(MIB) for use with network management protocols in the Internet
community. In particular, it defines objects for managing IEEE 802.3
Medium Attachment Units (MAUs). This document obsoletes RFC 3636.
It amends that specification by moving MAU type OBJECT-IDENTITY
definitions and relevant textual conventions into a separate Internet
Assigned Number Authority (IANA) maintained MIB module. In addition,
management information is added to enable support for Ethernet in the
First Mile (EFM) and 10GBASE-CX4 MAUs.
Beili Standards Track [Page 1]
RFC 4836 MAU MIB April 2007
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. The Internet-Standard Management Framework . . . . . . . . . . 3
3. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.1. Relationship to RFC 3636 . . . . . . . . . . . . . . . . . 4
3.2. Relationship to Other MIBs . . . . . . . . . . . . . . . . 5
3.2.1. Relationship to the Interfaces MIB . . . . . . . . . . 5
3.2.2. Relationship to the 802.3 Repeater MIB Module . . . . 6
3.3. Management of Internal MAUs . . . . . . . . . . . . . . . 6
3.4. Mapping of IEEE 802.3 Managed Objects . . . . . . . . . . 6
3.5. Addition of New MAU Types . . . . . . . . . . . . . . . . 9
3.5.1. dot3MauType OBJECT-IDENTITIES . . . . . . . . . . . . 9
3.5.2. IANAifMauTypeListBits TEXTUAL-CONVENTION . . . . . . . 9
3.5.3. IANAifMauMediaAvailable TEXTUAL-CONVENTION . . . . . . 9
3.5.4. IANAifMauAutoNegCapBits TEXTUAL-CONVENTION . . . . . . 10
3.5.5. JackType TEXTUAL-CONVENTION . . . . . . . . . . . . . 10
4. MAU MIB Definitions . . . . . . . . . . . . . . . . . . . . . 10
5. IANA-Maintained MAU TC Definitions . . . . . . . . . . . . . . 46
6. Security Considerations . . . . . . . . . . . . . . . . . . . 62
7. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 63
8. Acknowledgments . . . . . . . . . . . . . . . . . . . . . . . 63
9. References . . . . . . . . . . . . . . . . . . . . . . . . . . 64
9.1. Normative References . . . . . . . . . . . . . . . . . . . 64
9.2. Informative References . . . . . . . . . . . . . . . . . . 66
Beili Standards Track [Page 2]
RFC 4836 MAU MIB April 2007
1. Introduction
This document defines a portion of the Management Information Base
(MIB) for use with network management protocols in the Internet
community. In particular, it defines objects for managing IEEE 802.3
[IEEE802.3] Medium Attachment Units (MAUs).
The previous version of this document, RFC 3636 [RFC3636], defined a
single MIB module. This document splits the original MIB module into
two, putting frequently updated object identities and textual
conventions into a separate, IANA-maintained MIB module, in order to
decrease the need of updating the basic MAU MIB module.
The first version of the IANA-maintained MIB module also extends the
list of managed objects to support Ethernet in the First Mile (EFM)
and 10GBASE-CX4 interfaces.
Ethernet technology, as defined by the 802.3 Working Group of the
IEEE, continues to evolve, with scalable increases in speed, new
types of cabling and interfaces, and new features. This evolution
may require changes in the managed objects in order to reflect this
new functionality. This document, as with other documents issued by
this working group, reflects a certain stage in the evolution of
Ethernet technology. In the future, this document might be revised,
or new documents might be issued by the Ethernet Interfaces and Hub
MIB Working Group, in order to reflect the evolution of Ethernet
technology.
2. The Internet-Standard Management Framework
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to section 7 of
RFC 3410 [RFC3410].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. MIB objects are generally
accessed through the Simple Network Management Protocol (SNMP).
Objects in the MIB are defined using the mechanisms defined in the
Structure of Management Information (SMI). This memo specifies a MIB
module that is compliant to the SMIv2, which is described in STD 58,
RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
[RFC2580].
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in RFC 2119 [RFC2119].
Beili Standards Track [Page 3]
RFC 4836 MAU MIB April 2007
3. Overview
Instances of these object types represent attributes of an IEEE 802.3
MAU. Several types of MAUs are defined in the IEEE 802.3 CSMA/CD
standard [IEEE802.3]. These MAUs may be connected to IEEE 802.3
repeaters or to 802.3 (Ethernet-like) interfaces. For convenience,
this document refers to these devices as "repeater MAUs" and
"interface MAUs."
The definitions presented here are based on Section 30.5, "Layer
Management for 10 Mb/s, 100 Mb/s, 1000 Mb/s, and 10 Gb/s Medium
Attachment Units (MAUs)", Section 30.6, "Management for link Auto-
Negotiation", and Annex 30A, "GDMO Specifications for 802.3 managed
object classes" of IEEE Std. 802.3-2005 [IEEE802.3]. This
specification is intended to provide for management of all types of
Ethernet/802.3 MAUs.
3.1. Relationship to RFC 3636
The management definitions provided in this document are intended to
be a superset of those defined by RFC 3636 [RFC3636].
In order to decrease the need of updating the basic MAU MIB module
due to the new MAU type, Media Available state, Auto Negotiation
capability and/or Jack type introduction, all relevant object
identities and textual conventions have been moved to a separate,
IANA-maintained MIB module IANA-MAU-MIB, the first version of which
is defined in this document. Thus when a new MAU type, Media
Available state, Auto Negotiation capability, and/or Jack type is
defined by the IEEE 802.3 working group, only the IANA-maintained
module needs to be revised, leaving the basic MAU-MIB module defined
in this document unchanged.
In addition, the new definitions are added to the IANA-maintained MIB
module, to support Ethernet in the First Mile (EFM) and 10GBASE-CX4
interfaces, defined in IEEE Std 802.3ah-2004 [IEEE802.3ah] and IEEE
Std 802.3ak-2004 [IEEE802.3ak] respectively, now part of IEEE Std
802.3-2005 [IEEE802.3].
It should be noted that the changes made in this revision will not be
entirely backward-compatible with MIB modules that currently import
MAU type object identity descriptors from the MAU-MIB; such modules
will need to be revised to import those DESCRIPTORS from the IANA-
MAU-MIB. Similarly, any management applications that process the
object identity definitions (e.g., to present the DESCRIPTION text to
a user) will need to get those definitions from the IANA-MAU-MIB
instead of the MAU-MIB. While it is true that changes that require
such adjustments are not strictly compliant with the SMIv2 rules
Beili Standards Track [Page 4]
RFC 4836 MAU MIB April 2007
governing MIB module revisions (see [RFC2578] Section 10), in this
case continued high maintenance costs that would result from not
making these changes make the deviation from the rules justified. It
should be noted that the working group was not able to find any
examples of MIB modules or management applications that would
actually be negatively affected by the changes.
3.2. Relationship to Other MIBs
It is assumed that an agent implementing MAU-MIB will also implement
(at least) the 'system' group defined in the SNMPv2 MIB [RFC3418].
The following sections identify other MIBs that such an agent should
implement.
3.2.1. Relationship to the Interfaces MIB
The sections of this document that define interface MAU-related
objects specify an extension to the Interfaces MIB [RFC2863]. An
agent implementing these interface-MAU related objects MUST also
implement the relevant groups of the ifCompliance3 MODULE-COMPLIANCE
statement of the Interface MIB. The value of the object ifMauIfIndex
is the same as the value of 'ifIndex' used to instantiate the
interface to which the given MAU is connected.
It is REQUIRED that an agent implementing the interface-MAU related
objects in the MAU-MIB will also fully comply with the
dot3Compliance2 MODULE-COMPLIANCE statement of the Ethernet-like
Interfaces MIB, [RFC3635]. Furthermore, when the interface-MAU
related objects are used to manage a 10GBASE-W PHY -- i.e., when
ifMauType is equal to dot3MauType10GigBaseW or any other 10GBASE-W
variant -- then the agent MUST also support the Ethernet WAN
Interface Sublayer (WIS) MIB [RFC3637] and must follow the interface
layering model specified therein. In that case the value of the
object ifMauIfIndex is the same as the value of 'ifIndex' for the
layer at the top of the stack, i.e., for the ifTable entry that has
'ifType' equal to ethernetCsmacd(6). If the interface-MAU related
objects are used to manage a PHY that allows the MAU type to be
changed dynamically, then the agent SHALL create ifTable,
ifStackTable, and ifInvStackTable entries that pertain to the WIS
when ifMauDefaultType is changed to a 10GBASEW variant (i.e., one of
dot3MauType10GigBaseW, dot3MauType10GigBaseEW,
dot3MauType10GigBaseLW, or dot3MauType10GigBaseSW) from any other
type, and shall destroy the WIS-related entries when ifMauDefaultType
is changed to a non- 10GBASE-W type. The agent SHALL also change the
values of 'ifConnectorPresent' and 'ifHighSpeed' in the ifTable entry
indexed by ifMauIfIndex as specified in [RFC3635] and [RFC3637] when
ifMauDefaultType is manipulated in this way, but SHALL NOT otherwise
alter that entry.
Beili Standards Track [Page 5]
RFC 4836 MAU MIB April 2007
(Note that repeater ports are not represented as interfaces in the
Interface MIB.)
3.2.2. Relationship to the 802.3 Repeater MIB Module
The section of this document that defines repeater MAU-related
objects specifies an extension to the 802.3 Repeater MIB defined in
[RFC2108]. An agent implementing these repeater-MAU related objects
MUST also comply with the snmpRptrModCompl compliance statement of
the 802.3 Repeater MIB module.
The values of 'rpMauGroupIndex' and 'rpMauPortIndex' used to
instantiate a repeater MAU variable SHALL be the same as the values
of 'rptrPortGroupIndex' and 'rptrPortIndex' used to instantiate the
port that the given MAU is connected to.
3.3. Management of Internal MAUs
In some situations, a MAU can be "internal" -- i.e., its
functionality is implemented entirely within a device. For example,
a managed repeater may contain an internal repeater-MAU and/or an
internal interface-MAU through which management communications
originating on one of the repeater's external ports pass, in order to
reach the management agent associated with the repeater. Such
internal MAUs may or may not be managed. If they are managed,
objects describing their attributes should appear in the appropriate
MIB subtree: dot3RpMauBasicGroup for internal repeater-MAUs and
dot3IfMauBasicGroup for internal interface-MAUs.
3.4. Mapping of IEEE 802.3 Managed Objects
This section contains the mapping between relevant managed objects
(attributes) defined in [IEEE802.3] Clause 30, and managed objects
defined in this document.
Beili Standards Track [Page 6]
RFC 4836 MAU MIB April 2007
+----------------------------------+--------------------------------+
| IEEE 802.3 Managed Object | Corresponding SNMP Object |
+----------------------------------+--------------------------------+
| oMAU | |
+----------------------------------+--------------------------------+
| .aMAUID | rpMauIndex or ifMauIndex or |
| | broadMauIndex |
+----------------------------------+--------------------------------+
| .aMAUType | rpMauType or ifMauType |
+----------------------------------+--------------------------------+
| .aMAUTypeList | ifMauTypeListBits |
+----------------------------------+--------------------------------+
| .aMediaAvailable | rpMauMediaAvailable or |
| | ifMauMediaAvailable |
+----------------------------------+--------------------------------+
| .aLoseMediaCounter | rpMauMediaAvailableStateExits |
| | or |
| | ifMauMediaAvailableStateExits |
+----------------------------------+--------------------------------+
| .aJabber | rpMauJabberState and |
| | rpMauJabberingStateEnters or |
| | ifMauJabberState and |
| | ifMauJabberingStateEnters |
+----------------------------------+--------------------------------+
| .aMAUAdminState | rpMauStatus or ifMauStatus |
+----------------------------------+--------------------------------+
| .aBbMAUXmitRcvSplitType | broadMauXmtRcvSplitType |
+----------------------------------+--------------------------------+
| .aBroadbandFrequencies | broadMauXmtCarrierFreq and |
| | broadMauTranslationFreq |
+----------------------------------+--------------------------------+
| .aFalseCarriers | rpMauFalseCarriers or |
| | ifMauFalseCarriers |
+----------------------------------+--------------------------------+
| .acResetMAU | rpMauStatus or ifMauStatus |
+----------------------------------+--------------------------------+
| .acMAUAdminControl | rpMauStatus or ifMauStatus |
+----------------------------------+--------------------------------+
| .nJabber | rpMauJabberTrap or |
| | ifMauJabberTrap |
+----------------------------------+--------------------------------+
| oAutoNegotiation | |
+----------------------------------+--------------------------------+
| .aAutoNegID | ifMauIndex |
+----------------------------------+--------------------------------+
| .aAutoNegAdminState | ifMauAutoNegAdminStatus |
+----------------------------------+--------------------------------+
| .aAutoNegRemoteSignalling | ifMauAutoNegRemoteSignalling |
Beili Standards Track [Page 7]
RFC 4836 MAU MIB April 2007
| .aAutoNegAutoConfig | ifMauAutoNegConfig |
+----------------------------------+--------------------------------+
| .aAutoNegLocalTechnologyAbility | ifMauAutoNegCapabilityBits |
+----------------------------------+--------------------------------+
| .aAutoNegAdvertisedTechnologyAbi | ifMauAutoNegAdvertisedBits and |
| lity | ifMauAutoNegRemoteFaultAdverti |
| | sed |
+----------------------------------+--------------------------------+
| .aAutoNegReceivedTechnologyAbili | ifMauAutoNegReceivedBits and |
| ty | ifMauAutoNegRemoteFaultReceive |
| | d |
+----------------------------------+--------------------------------+
| .acAutoNegRestartAutoConfig | ifMauAutoNegRestart |
+----------------------------------+--------------------------------+
| .acAutoNegAdminControl | ifMauAutoNegAdminStatus |
+----------------------------------+--------------------------------+
Table 1: Mapping of IEEE 802.3 Managed Objects
The following IEEE 802.3 managed objects have not been included in
the MAU-MIB for the following reasons.
+------------------------------------+------------------------------+
| IEEE 802.3 Managed Object | Reason for exclusion |
+------------------------------------+------------------------------+
| oMAU | |
+------------------------------------+------------------------------+
| .aIdleErrorCount | Only useful for 100BaseT2, |
| | which is not widely |
| | implemented. |
+------------------------------------+------------------------------+
| oAutoNegotiation | |
+------------------------------------+------------------------------+
| .aAutoNegLocalSelectorAbility | Only needed for support of |
| | isoethernet (802.9a), which |
| | is not supported by MAU-MIB. |
+------------------------------------+------------------------------+
| .aAutoNegAdvertisedSelectorAbility | |
+------------------------------------+------------------------------+
| .aAutoNegReceivedSelectorAbility | |
+------------------------------------+------------------------------+
Table 2: Unmapped IEEE 802.3 Managed Objects
Beili Standards Track [Page 8]
RFC 4836 MAU MIB April 2007
3.5. Addition of New MAU Types
3.5.1. dot3MauType OBJECT-IDENTITIES
The dot3MauType OBJECT IDENTIFIER and its OBJECT-IDENTITY definitions
has been moved from the MAU-MIB into the IANA-maintained IANA-MAU-
MIB, the first version of which is defined in this document.
When a new IEEE 802.3 MAU is defined, IANA can re-issue a version of
IANA-MAU-MIB with the new dot3MauType OBJECT-IDENTITY and its
matching IANAifMauTypeListBits textual convention value and,
possibly, with new IANAifMauMediaAvailable, IANAifMauAutoNegCapBits,
and/or IANAifJackType values.
An Expert Review, as defined in RFC 2434 [RFC2434], is REQUIRED for
the addition of the new MAU, Media Available states, Auto Negotiation
capabilities, and/or Jack types.
In some cases, new MAU types may require additional managed objects
or may have side effects on the behavior of existing managed objects.
In such cases a standards-track specification (which may be a new
document or a revision of this document) is also REQUIRED. Any such
document is REQUIRED to note any special properties of the MAU types
that it defines - for example, side effects on the ifStackTable as
noted in this document for 10GBASE-W MAUs.
3.5.2. IANAifMauTypeListBits TEXTUAL-CONVENTION
The syntax of ifMauTypeListBits is changed to be a textual
convention, such that the enumerated integer values are now defined
in the textual convention IANAifMauTypeListBits, which can be re-
specified (with additional values, when defined by IEEE 802.3) in the
IANA-maintained MIB module without issuing a new version of this
document.
3.5.3. IANAifMauMediaAvailable TEXTUAL-CONVENTION
The syntax of ifMauMediaAvailable and rpMauMediaAvailable is changed
to be a textual convention, such that the enumerated integer values
are now defined in the textual convention IANAifMauMediaAvailable,
which can be re-specified (with additional values, when defined by
IEEE 802.3) in the IANA-maintained MIB module without issuing a new
version of this document.
Beili Standards Track [Page 9]
RFC 4836 MAU MIB April 2007
3.5.4. IANAifMauAutoNegCapBits TEXTUAL-CONVENTION
The syntax of ifMauAutoNegCapabilityBits,
ifMauAutoNegCapAdvertisedBits, and ifMauAutoNegCapReceivedBits
objects is changed to be a textual convention, such that the
enumerated integer values are now defined in the textual convention
IANAifMauAutoNegCapBits, which can be re-specified (with additional
values, when defined by IEEE 802.3) in the IANA-maintained MIB module
without issuing a new version of this document.
3.5.5. JackType TEXTUAL-CONVENTION
The JackType Textual Convention has been deprecated in favor of the
IANAifJackType defined in the IANA-maintained MIB module, so the new
Jack types can be added (when defined by IEEE 802.3) without issuing
a new version of this document.
4. MAU MIB Definitions
MAU-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter32, Integer32, Counter64,
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, mib-2
FROM SNMPv2-SMI -- RFC 2578
TruthValue, AutonomousType, TEXTUAL-CONVENTION
FROM SNMPv2-TC -- RFC 2579
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF -- RFC 2580
InterfaceIndex
FROM IF-MIB -- RFC 2863
IANAifMauTypeListBits, IANAifMauMediaAvailable,
IANAifMauAutoNegCapBits, IANAifJackType
FROM IANA-MAU-MIB
-- http://www.iana.org/assignments/ianamau-mib
;
mauMod MODULE-IDENTITY
LAST-UPDATED "200704210000Z" -- April 21, 2007
ORGANIZATION "IETF Ethernet Interfaces and Hub MIB Working Group"
CONTACT-INFO
"WG charter:
http://www.ietf.org/html.charters/hubmib-charter.html
Mailing Lists:
General Discussion: hubmib@ietf.org
To Subscribe: hubmib-request@ietf.org
In Body: subscribe your_email_address
Beili Standards Track [Page 10]
RFC 4836 MAU MIB April 2007
Chair: Bert Wijnen
Postal: Alcatel-Lucent
Schagen 33
3461 GL Linschoten
Netherlands
Phone: +31-348-407-775
EMail: bwijnen@alcatel-lucent.com
Editor: Edward Beili
Postal: Actelis Networks Inc.
25 Bazel St., P.O.B. 10173
Petach-Tikva 10173
Israel
Tel: +972-3-924-3491
EMail: edward.beili@actelis.com"
DESCRIPTION
"Management information for 802.3 MAUs.
The following reference is used throughout this MIB module:
[IEEE802.3] refers to:
IEEE Std 802.3, 2005 Edition: 'IEEE Standard for Information
technology - Telecommunications and information exchange
between systems - Local and metropolitan area networks -
Specific requirements - Part 3: Carrier sense multiple
access with collision detection (CSMA/CD) access method and
physical layer specifications'.
Of particular interest is Clause 30, 'Management'.
Copyright (C) The IETF Trust (2007).
This version of this MIB module is part of RFC 4836;
see the RFC itself for full legal notices."
REVISION "200704210000Z" -- April 21, 2007
DESCRIPTION "Updated to reference IANA maintaned textual
conventions for MAU types, Media Availability state,
Auto Negotiation capabilities, and jack types,
instead of using internally defined values.
This version is published as RFC 4836."
REVISION "200309190000Z" -- September 19, 2003
DESCRIPTION "Updated to include support for 10 Gb/s MAUs.
This resulted in the following revisions:
- Added OBJECT-IDENTITY definitions for
10 gigabit MAU types
Beili Standards Track [Page 11]
RFC 4836 MAU MIB April 2007
- Added fiberLC jack type to JackType TC
- Extended ifMauTypeListBits with bits for
the 10 gigabit MAU types
- Added enumerations to ifMauMediaAvailable,
and updated its DESCRIPTION to reflect
behaviour at 10 Gb/s
- Added 64-bit version of ifMauFalseCarriers
and added mauIfGrpHCStats object group to
contain the new object
- Deprecated mauModIfCompl2 and replaced it
with mauModIfCompl3, which includes the new
object group
This version published as RFC 3636."
REVISION "199908240400Z" -- August 24, 1999
DESCRIPTION "This version published as RFC 2668. Updated
to include support for 1000 Mb/sec
MAUs and flow control negotiation."
REVISION "199710310000Z" -- October 31, 1997
DESCRIPTION "Version published as RFC 2239."
REVISION "199309300000Z" -- September 30, 1993
DESCRIPTION "Initial version, published as RFC 1515."
::= { snmpDot3MauMgt 6 }
snmpDot3MauMgt OBJECT IDENTIFIER ::= { mib-2 26 }
-- Textual Conventions
JackType ::= TEXTUAL-CONVENTION
STATUS deprecated
DESCRIPTION "********* THIS TC IS DEPRECATED **********
This TC has been deprecated in favour of
IANAifJackType.
Common enumeration values for repeater
and interface MAU jack types."
SYNTAX INTEGER {
other(1),
rj45(2),
rj45S(3), -- rj45 shielded
db9(4),
bnc(5),
fAUI(6), -- female aui
Beili Standards Track [Page 12]
RFC 4836 MAU MIB April 2007
mAUI(7), -- male aui
fiberSC(8),
fiberMIC(9),
fiberST(10),
telco(11),
mtrj(12), -- fiber MT-RJ
hssdc(13), -- fiber channel style-2
fiberLC(14)
}
dot3RpMauBasicGroup
OBJECT IDENTIFIER ::= { snmpDot3MauMgt 1 }
dot3IfMauBasicGroup
OBJECT IDENTIFIER ::= { snmpDot3MauMgt 2 }
dot3BroadMauBasicGroup
OBJECT IDENTIFIER ::= { snmpDot3MauMgt 3 }
-- OIDs under the following branch are reserved for
-- the IANA-MAU-MIB to assign as MAU type values:
-- { snmpDot3MauMgt 4 }
dot3IfMauAutoNegGroup
OBJECT IDENTIFIER ::= { snmpDot3MauMgt 5 }
-- the following OID is the MODULE-IDENTITY value
-- for this MIB module: { snmpDot3MauMgt 6 }
--
-- The Basic Repeater MAU Table
--
rpMauTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpMauEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of descriptive and status information
about the MAU(s) attached to the ports of a
repeater."
::= { dot3RpMauBasicGroup 1 }
rpMauEntry OBJECT-TYPE
SYNTAX RpMauEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table, containing information
about a single MAU."
INDEX { rpMauGroupIndex,
rpMauPortIndex,
Beili Standards Track [Page 13]
RFC 4836 MAU MIB April 2007
rpMauIndex
}
::= { rpMauTable 1 }
RpMauEntry ::=
SEQUENCE {
rpMauGroupIndex Integer32,
rpMauPortIndex Integer32,
rpMauIndex Integer32,
rpMauType AutonomousType,
rpMauStatus INTEGER,
rpMauMediaAvailable IANAifMauMediaAvailable,
rpMauMediaAvailableStateExits Counter32,
rpMauJabberState INTEGER,
rpMauJabberingStateEnters Counter32,
rpMauFalseCarriers Counter32
}
rpMauGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION "This variable uniquely identifies the group
containing the port to which the MAU described
by this entry is connected.
Note: In practice, a group will generally be
a field-replaceable unit (i.e., module, card,
or board) that can fit in the physical system
enclosure, and the group number will correspond
to a number marked on the physical enclosure.
The group denoted by a particular value of this
object is the same as the group denoted by the
same value of rptrGroupIndex."
REFERENCE "RFC 2108, rptrGroupIndex."
::= { rpMauEntry 1 }
rpMauPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION "This variable uniquely identifies the repeater
port within group rpMauGroupIndex to which the
MAU described by this entry is connected."
REFERENCE "RFC 2108, rptrPortIndex."
Beili Standards Track [Page 14]
RFC 4836 MAU MIB April 2007
::= { rpMauEntry 2 }
rpMauIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION "This variable uniquely identifies the MAU
described by this entry from among other
MAUs connected to the same port
(rpMauPortIndex)."
REFERENCE "[IEEE802.3], 30.5.1.1.1, aMAUID."
::= { rpMauEntry 3 }
rpMauType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the MAU type. Values for
standard IEEE 802.3 MAU types are defined in the
IANA maintained IANA-MAU-MIB module, as
OBJECT-IDENTITIES of dot3MauType.
If the MAU type is unknown, the object identifier
zeroDotZero is returned."
REFERENCE "[IEEE802.3], 30.5.1.1.2, aMAUType."
::= { rpMauEntry 4 }
rpMauStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
operational(3),
standby(4),
shutdown(5),
reset(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The current state of the MAU. This object MAY
be implemented as a read-only object by those
agents and MAUs that do not implement software
control of the MAU state. Some agents may not
support setting the value of this object to some
of the enumerated values.
The value other(1) is returned if the MAU is in
a state other than one of the states 2 through
6.
Beili Standards Track [Page 15]
RFC 4836 MAU MIB April 2007
The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.
A MAU in the operational(3) state is fully
functional; it operates, and passes signals to its
attached DTE or repeater port in accordance to
its specification.
A MAU in standby(4) state forces DI and CI to
idle, and the media transmitter to idle or fault,
if supported. Standby(4) mode only applies to
link type MAUs. The state of
rpMauMediaAvailable is unaffected.
A MAU in shutdown(5) state assumes the same
condition on DI, CI, and the media transmitter,
as though it were powered down or not connected.
The MAU MAY return other(1) value for the
rpMauJabberState and rpMauMediaAvailable objects
when it is in this state. For an AUI, this
state will remove power from the AUI.
Setting this variable to the value reset(6)
resets the MAU in the same manner as a
power-off, power-on cycle of at least one-half
second would. The agent is not required to
return the value reset(6).
Setting this variable to the value
operational(3), standby(4), or shutdown(5)
causes the MAU to assume the respective state,
except that setting a mixing-type MAU or an AUI
to standby(4) will cause the MAU to enter the
shutdown state."
REFERENCE "[IEEE802.3], 30.5.1.1.7, aMAUAdminState,
30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1,
acResetMAU."
::= { rpMauEntry 5 }
rpMauMediaAvailable OBJECT-TYPE
SYNTAX IANAifMauMediaAvailable
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies Media Available state of
the MAU, complementary to the rpMauStatus. Values
for the standard IEEE 802.3 Media Available states
are defined in the IANA maintained IANA-MAU-MIB
Beili Standards Track [Page 16]
RFC 4836 MAU MIB April 2007
module, as IANAifMauMediaAvailable TC."
REFERENCE "[IEEE802.3], 30.5.1.1.4, aMediaAvailable."
::= { rpMauEntry 6 }
rpMauMediaAvailableStateExits OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of times that
rpMauMediaAvailable for this MAU instance leaves
the state available(3).
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of rptrMonitorPortLastChange."
REFERENCE "[IEEE802.3], 30.5.1.1.5, aLoseMediaCounter.
RFC 2108, rptrMonitorPortLastChange"
::= { rpMauEntry 7 }
rpMauJabberState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
noJabber(3),
jabbering(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value other(1) is returned if the jabber
state is not 2, 3, or 4. The agent MUST always
return other(1) for MAU type dot3MauTypeAUI.
The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.
If the MAU is not jabbering the agent returns
noJabber(3). This is the 'normal' state.
If the MAU is in jabber state the agent returns
the jabbering(4) value."
REFERENCE "[IEEE802.3], 30.5.1.1.6, aJabber.jabberFlag."
::= { rpMauEntry 8 }
rpMauJabberingStateEnters OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
Beili Standards Track [Page 17]
RFC 4836 MAU MIB April 2007
STATUS current
DESCRIPTION "A count of the number of times that
mauJabberState for this MAU instance enters the
state jabbering(4). For MAUs of type
dot3MauTypeAUI, dot3MauType100BaseT4,
dot3MauType100BaseTX, dot3MauType100BaseFX, and
all 1000Mbps types, this counter will always
indicate zero.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of rptrMonitorPortLastChange."
REFERENCE "[IEEE802.3], 30.5.1.1.6, aJabber.jabberCounter.
RFC 2108, rptrMonitorPortLastChange"
::= { rpMauEntry 9 }
rpMauFalseCarriers OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of false carrier events
during IDLE in 100BASE-X links. This counter
does not increment at the symbol rate. It can
increment after a valid carrier completion at a
maximum rate of once per 100 ms until the next
carrier event.
This counter increments only for MAUs of type
dot3MauType100BaseT4, dot3MauType100BaseTX,
dot3MauType100BaseFX, and all 1000Mbps types.
For all other MAU types, this counter will
always indicate zero.
The approximate minimum time for rollover of
this counter is 7.4 hours.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of rptrMonitorPortLastChange."
REFERENCE "[IEEE802.3], 30.5.1.1.10, aFalseCarriers.
RFC 2108, rptrMonitorPortLastChange"
::= { rpMauEntry 10 }
-- The rpJackTable applies to MAUs attached to repeaters
-- which have one or more external jacks (connectors).
Beili Standards Track [Page 18]
RFC 4836 MAU MIB April 2007
rpJackTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpJackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Information about the external jacks attached
to MAUs attached to the ports of a repeater."
::= { dot3RpMauBasicGroup 2 }
rpJackEntry OBJECT-TYPE
SYNTAX RpJackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table, containing information
about a particular jack."
INDEX { rpMauGroupIndex,
rpMauPortIndex,
rpMauIndex,
rpJackIndex
}
::= { rpJackTable 1 }
RpJackEntry ::=
SEQUENCE {
rpJackIndex Integer32,
rpJackType IANAifJackType
}
rpJackIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This variable uniquely identifies the jack
described by this entry from among other jacks
attached to the same MAU (rpMauIndex)."
::= { rpJackEntry 1 }
rpJackType OBJECT-TYPE
SYNTAX IANAifJackType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The jack connector type, as it appears on the
outside of the system."
::= { rpJackEntry 2 }
--
-- The Basic Interface MAU Table
--
Beili Standards Track [Page 19]
RFC 4836 MAU MIB April 2007
ifMauTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfMauEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of descriptive and status information
about MAU(s) attached to an interface."
::= { dot3IfMauBasicGroup 1 }
ifMauEntry OBJECT-TYPE
SYNTAX IfMauEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table, containing information
about a single MAU."
INDEX { ifMauIfIndex,
ifMauIndex
}
::= { ifMauTable 1 }
IfMauEntry ::=
SEQUENCE {
ifMauIfIndex InterfaceIndex,
ifMauIndex Integer32,
ifMauType AutonomousType,
ifMauStatus INTEGER,
ifMauMediaAvailable IANAifMauMediaAvailable,
ifMauMediaAvailableStateExits Counter32,
ifMauJabberState INTEGER,
ifMauJabberingStateEnters Counter32,
ifMauFalseCarriers Counter32,
ifMauTypeList Integer32,
ifMauDefaultType AutonomousType,
ifMauAutoNegSupported TruthValue,
ifMauTypeListBits IANAifMauTypeListBits,
ifMauHCFalseCarriers Counter64
}
ifMauIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION "This variable uniquely identifies the interface
to which the MAU described by this entry is
connected."
REFERENCE "RFC 2863, ifIndex"
::= { ifMauEntry 1 }
Beili Standards Track [Page 20]
RFC 4836 MAU MIB April 2007
ifMauIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION "This variable uniquely identifies the MAU
described by this entry from among other MAUs
connected to the same interface (ifMauIfIndex)."
REFERENCE "[IEEE802.3], 30.5.1.1.1, aMAUID."
::= { ifMauEntry 2 }
ifMauType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the MAU type. Values for
standard IEEE 802.3 MAU types are defined in the
IANA maintained IANA-MAU-MIB module, as
OBJECT-IDENTITIES of dot3MauType.
If the MAU type is unknown, the object identifier
zeroDotZero is returned.
This object represents the operational type of
the MAU, as determined by either 1) the result
of the auto-negotiation function or 2) if
auto-negotiation is not enabled or is not
implemented for this MAU, by the value of the
object ifMauDefaultType. In case 2), a set to
the object ifMauDefaultType will force the MAU
into the new operating mode."
REFERENCE "[IEEE802.3], 30.5.1.1.2, aMAUType."
::= { ifMauEntry 3 }
ifMauStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
operational(3),
standby(4),
shutdown(5),
reset(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The current state of the MAU. This object MAY
be implemented as a read-only object by those
agents and MAUs that do not implement software
control of the MAU state. Some agents may not
Beili Standards Track [Page 21]
RFC 4836 MAU MIB April 2007
support setting the value of this object to some
of the enumerated values.
The value other(1) is returned if the MAU is in
a state other than one of the states 2 through
6.
The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.
A MAU in the operational(3) state is fully
functional; it operates, and passes signals to its
attached DTE or repeater port in accordance to
its specification.
A MAU in standby(4) state forces DI and CI to
idle and the media transmitter to idle or fault,
if supported. Standby(4) mode only applies to
link type MAUs. The state of
ifMauMediaAvailable is unaffected.
A MAU in shutdown(5) state assumes the same
condition on DI, CI, and the media transmitter,
as though it were powered down or not connected.
The MAU MAY return other(1) value for the
ifMauJabberState and ifMauMediaAvailable objects
when it is in this state. For an AUI, this
state will remove power from the AUI.
Setting this variable to the value reset(6)
resets the MAU in the same manner as a
power-off, power-on cycle of at least one-half
second would. The agent is not required to
return the value reset(6).
Setting this variable to the value
operational(3), standby(4), or shutdown(5)
causes the MAU to assume the respective state,
except that setting a mixing-type MAU or an AUI
to standby(4) will cause the MAU to enter the
shutdown state."
REFERENCE "[IEEE802.3], 30.5.1.1.7, aMAUAdminState,
30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1,
acResetMAU."
::= { ifMauEntry 4 }
ifMauMediaAvailable OBJECT-TYPE
Beili Standards Track [Page 22]
RFC 4836 MAU MIB April 2007
SYNTAX IANAifMauMediaAvailable
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies Media Available state of
the MAU, complementary to the ifMauStatus. Values
for the standard IEEE 802.3 Media Available states
are defined in the IANA maintained IANA-MAU-MIB
module, as IANAifMauMediaAvailable TC."
REFERENCE "[IEEE802.3], 30.5.1.1.4, aMediaAvailable."
::= { ifMauEntry 5 }
ifMauMediaAvailableStateExits OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of times that
ifMauMediaAvailable for this MAU instance leaves
the state available(3).
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE802.3], 30.5.1.1.5, aLoseMediaCounter.
RFC 2863, ifCounterDiscontinuityTime."
::= { ifMauEntry 6 }
ifMauJabberState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
noJabber(3),
jabbering(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value other(1) is returned if the jabber
state is not 2, 3, or 4. The agent MUST always
return other(1) for MAU type dot3MauTypeAUI.
The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.
If the MAU is not jabbering the agent returns
noJabber(3). This is the 'normal' state.
If the MAU is in jabber state the agent returns
Beili Standards Track [Page 23]
RFC 4836 MAU MIB April 2007
the jabbering(4) value."
REFERENCE "[IEEE802.3], 30.5.1.1.6, aJabber.jabberFlag."
::= { ifMauEntry 7 }
ifMauJabberingStateEnters OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of times that
mauJabberState for this MAU instance enters the
state jabbering(4). This counter will always
indicate zero for MAUs of type dot3MauTypeAUI
and those of speeds above 10Mbps.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE802.3], 30.5.1.1.6, aJabber.jabberCounter.
RFC 2863, ifCounterDiscontinuityTime."
::= { ifMauEntry 8 }
ifMauFalseCarriers OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of false carrier events
during IDLE in 100BASE-X and 1000BASE-X links.
For all other MAU types, this counter will
always indicate zero. This counter does not
increment at the symbol rate.
It can increment after a valid carrier
completion at a maximum rate of once per 100 ms
for 100BASE-X and once per 10us for 1000BASE-X
until the next CarrierEvent.
This counter can roll over very quickly. A
management station is advised to poll the
ifMauHCFalseCarriers instead of this counter in
order to avoid loss of information.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE802.3], 30.5.1.1.10, aFalseCarriers.
Beili Standards Track [Page 24]
RFC 4836 MAU MIB April 2007
RFC 2863, ifCounterDiscontinuityTime."
::= { ifMauEntry 9 }
ifMauTypeList OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This object has been deprecated in favour of
ifMauTypeListBits.
A value that uniquely identifies the set of
possible IEEE 802.3 types that the MAU could be.
The value is a sum that initially takes the
value zero. Then, for each type capability of
this MAU, 2 raised to the power noted below is
added to the sum. For example, a MAU that has
the capability to be only 10BASE-T would have a
value of 512 (2**9). In contrast, a MAU that
supports both 10Base-T (full duplex) and
100BASE-TX (full duplex) would have a value of
((2**11) + (2**16)), or 67584.
The powers of 2 assigned to the capabilities are
these:
Power Capability
0 other or unknown
1 AUI
2 10BASE-5
3 FOIRL
4 10BASE-2
5 10BASE-T duplex mode unknown
6 10BASE-FP
7 10BASE-FB
8 10BASE-FL duplex mode unknown
9 10BROAD36
10 10BASE-T half duplex mode
11 10BASE-T full duplex mode
12 10BASE-FL half duplex mode
13 10BASE-FL full duplex mode
14 100BASE-T4
15 100BASE-TX half duplex mode
16 100BASE-TX full duplex mode
17 100BASE-FX half duplex mode
18 100BASE-FX full duplex mode
19 100BASE-T2 half duplex mode
Beili Standards Track [Page 25]
RFC 4836 MAU MIB April 2007
20 100BASE-T2 full duplex mode
If auto-negotiation is present on this MAU, this
object will map to ifMauAutoNegCapability."
::= { ifMauEntry 10 }
ifMauDefaultType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object identifies the default
administrative baseband MAU type to be used in
conjunction with the operational MAU type
denoted by ifMauType.
The set of possible values for this object is
the same as the set defined for the ifMauType
object.
This object represents the
administratively-configured type of the MAU. If
auto-negotiation is not enabled or is not
implemented for this MAU, the value of this
object determines the operational type of the
MAU. In this case, a set to this object will
force the MAU into the specified operating mode.
If auto-negotiation is implemented and enabled
for this MAU, the operational type of the MAU
is determined by auto-negotiation, and the value
of this object denotes the type to which the MAU
will automatically revert if/when
auto-negotiation is later disabled.
NOTE TO IMPLEMENTORS: It may be necessary to
provide for underlying hardware implementations
which do not follow the exact behavior specified
above. In particular, when
ifMauAutoNegAdminStatus transitions from enabled
to disabled, the agent implementation MUST
ensure that the operational type of the MAU (as
reported by ifMauType) correctly transitions to
the value specified by this object, rather than
continuing to operate at the value earlier
determined by the auto-negotiation function."
REFERENCE "[IEEE802.3], 30.5.1.1.1, aMAUID, and 22.2.4.1.4."
::= { ifMauEntry 11 }
Beili Standards Track [Page 26]
RFC 4836 MAU MIB April 2007
ifMauAutoNegSupported OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates whether or not
auto-negotiation is supported on this MAU."
::= { ifMauEntry 12 }
ifMauTypeListBits OBJECT-TYPE
SYNTAX IANAifMauTypeListBits
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value that uniquely identifies the set of
possible IEEE 802.3 types that the MAU could be.
If auto-negotiation is present on this MAU, this
object will map to ifMauAutoNegCapabilityBits.
Note that this MAU may be capable of operating
as a MAU type that is beyond the scope of this
MIB. This is indicated by returning the
bit value bOther in addition to any bit values
for standard capabilities that are listed in the
IANAifMauTypeListBits TC."
::= { ifMauEntry 13 }
ifMauHCFalseCarriers OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of false carrier events
during IDLE in 100BASE-X and 1000BASE-X links.
For all other MAU types, this counter will
always indicate zero. This counter does not
increment at the symbol rate.
This counter is a 64-bit version of
ifMauFalseCarriers. Since the 32-bit version of
this counter can roll over very quickly,
management stations are advised to poll the
64-bit version instead, in order to avoid loss
of information.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE802.3], 30.5.1.1.10, aFalseCarriers.
Beili Standards Track [Page 27]
RFC 4836 MAU MIB April 2007
RFC 2863, ifCounterDiscontinuityTime."
::= { ifMauEntry 14 }
-- The ifJackTable applies to MAUs attached to interfaces
-- which have one or more external jacks (connectors).
ifJackTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfJackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Information about the external jacks attached
to MAUs attached to an interface."
::= { dot3IfMauBasicGroup 2 }
ifJackEntry OBJECT-TYPE
SYNTAX IfJackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table, containing information
about a particular jack."
INDEX { ifMauIfIndex,
ifMauIndex,
ifJackIndex
}
::= { ifJackTable 1 }
IfJackEntry ::=
SEQUENCE {
ifJackIndex Integer32,
ifJackType IANAifJackType
}
ifJackIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This variable uniquely identifies the jack
described by this entry from among other jacks
attached to the same MAU."
::= { ifJackEntry 1 }
ifJackType OBJECT-TYPE
SYNTAX IANAifJackType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The jack connector type, as it appears on the
outside of the system."
::= { ifJackEntry 2 }
Beili Standards Track [Page 28]
RFC 4836 MAU MIB April 2007
--
-- The MAU Auto-Negotiation Table
--
ifMauAutoNegTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfMauAutoNegEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Configuration and status objects for the
auto-negotiation function of MAUs attached to
interfaces.
The ifMauAutoNegTable applies to systems in
which auto-negotiation is supported on one or
more MAUs attached to interfaces. Note that if
auto-negotiation is present and enabled, the
ifMauType object reflects the result of the
auto-negotiation function."
::= { dot3IfMauAutoNegGroup 1 }
ifMauAutoNegEntry OBJECT-TYPE
SYNTAX IfMauAutoNegEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table, containing configuration
and status information for the auto-negotiation
function of a particular MAU."
INDEX { ifMauIfIndex,
ifMauIndex
}
::= { ifMauAutoNegTable 1 }
IfMauAutoNegEntry ::=
SEQUENCE {
ifMauAutoNegAdminStatus INTEGER,
ifMauAutoNegRemoteSignaling INTEGER,
ifMauAutoNegConfig INTEGER,
ifMauAutoNegCapability Integer32,
ifMauAutoNegCapAdvertised Integer32,
ifMauAutoNegCapReceived Integer32,
ifMauAutoNegRestart INTEGER,
ifMauAutoNegCapabilityBits IANAifMauAutoNegCapBits,
ifMauAutoNegCapAdvertisedBits IANAifMauAutoNegCapBits,
ifMauAutoNegCapReceivedBits IANAifMauAutoNegCapBits,
ifMauAutoNegRemoteFaultAdvertised INTEGER,
ifMauAutoNegRemoteFaultReceived INTEGER
}
Beili Standards Track [Page 29]
RFC 4836 MAU MIB April 2007
ifMauAutoNegAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Setting this object to enabled(1) will cause
the interface that has the auto-negotiation
signaling ability to be enabled.
If the value of this object is disabled(2) then
the interface will act as it would if it had no
auto-negotiation signaling. Under these
conditions, an IEEE 802.3 MAU will immediately
be forced to the state indicated by the value of
the object ifMauDefaultType.
NOTE TO IMPLEMENTORS: When
ifMauAutoNegAdminStatus transitions from enabled
to disabled, the agent implementation MUST
ensure that the operational type of the MAU (as
reported by ifMauType) correctly transitions to
the value specified by the ifMauDefaultType
object, rather than continuing to operate at the
value earlier determined by the auto-negotiation
function."
REFERENCE "[IEEE802.3], 30.6.1.1.2, aAutoNegAdminState,
and 30.6.1.2.2, acAutoNegAdminControl."
::= { ifMauAutoNegEntry 1 }
ifMauAutoNegRemoteSignaling OBJECT-TYPE
SYNTAX INTEGER {
detected(1),
notdetected(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value indicating whether the remote end of
the link is using auto-negotiation signaling. It
takes the value detected(1) if and only if,
during the previous link negotiation, FLP Bursts
were received."
REFERENCE "[IEEE802.3], 30.6.1.1.3,
aAutoNegRemoteSignaling."
::= { ifMauAutoNegEntry 2 }
ifMauAutoNegConfig OBJECT-TYPE
Beili Standards Track [Page 30]
RFC 4836 MAU MIB April 2007
SYNTAX INTEGER {
other(1),
configuring(2),
complete(3),
disabled(4),
parallelDetectFail(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value indicating the current status of the
auto-negotiation process. The enumeration
parallelDetectFail(5) maps to a failure in
parallel detection as defined in 28.2.3.1 of
[IEEE802.3]."
REFERENCE "[IEEE802.3], 30.6.1.1.4, aAutoNegAutoConfig."
::= { ifMauAutoNegEntry 4 }
ifMauAutoNegCapability OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This object has been deprecated in favour of
ifMauAutoNegCapabilityBits.
A value that uniquely identifies the set of
capabilities of the local auto-negotiation
entity. The value is a sum that initially
takes the value zero. Then, for each capability
of this interface, 2 raised to the power noted
below is added to the sum. For example, an
interface that has the capability to support
only 100Base-TX half duplex would have a value
of 32768 (2**15). In contrast, an interface
that supports both 100Base-TX half duplex and
100Base-TX full duplex would have a value of
98304 ((2**15) + (2**16)).
The powers of 2 assigned to the capabilities are
these:
Power Capability
0 other or unknown
(1-9) (reserved)
10 10BASE-T half duplex mode
11 10BASE-T full duplex mode
12 (reserved)
Beili Standards Track [Page 31]
RFC 4836 MAU MIB April 2007
13 (reserved)
14 100BASE-T4
15 100BASE-TX half duplex mode
16 100BASE-TX full duplex mode
17 (reserved)
18 (reserved)
19 100BASE-T2 half duplex mode
20 100BASE-T2 full duplex mode
Note that interfaces that support this MIB may
have capabilities that extend beyond the scope
of this MIB."
REFERENCE "[IEEE802.3], 30.6.1.1.5,
aAutoNegLocalTechnologyAbility."
::= { ifMauAutoNegEntry 5 }
ifMauAutoNegCapAdvertised OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This object has been deprecated in favour of
ifMauAutoNegCapAdvertisedBits.
A value that uniquely identifies the set of
capabilities advertised by the local
auto-negotiation entity. Refer to
ifMauAutoNegCapability for a description of the
possible values of this object.
Capabilities in this object that are not
available in ifMauAutoNegCapability cannot be
enabled."
REFERENCE "[IEEE802.3], 30.6.1.1.6,
aAutoNegAdvertisedTechnologyAbility."
::= { ifMauAutoNegEntry 6 }
ifMauAutoNegCapReceived OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This object has been deprecated in favour of
ifMauAutoNegCapReceivedBits.
A value that uniquely identifies the set of
Beili Standards Track [Page 32]
RFC 4836 MAU MIB April 2007
capabilities received from the remote
auto-negotiation entity. Refer to
ifMauAutoNegCapability for a description of the
possible values of this object.
Note that interfaces that support this MIB may
be attached to remote auto-negotiation entities
that have capabilities beyond the scope of this
MIB."
REFERENCE "[IEEE802.3], 30.6.1.1.7,
aAutoNegReceivedTechnologyAbility."
::= { ifMauAutoNegEntry 7 }
ifMauAutoNegRestart OBJECT-TYPE
SYNTAX INTEGER {
restart(1),
norestart(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "If the value of this object is set to
restart(1) then this will force auto-negotiation
to begin link renegotiation. If auto-negotiation
signaling is disabled, a write to this object
has no effect.
Setting the value of this object to norestart(2)
has no effect."
REFERENCE "[IEEE802.3], 30.6.1.2.1,
acAutoNegRestartAutoConfig."
::= { ifMauAutoNegEntry 8 }
ifMauAutoNegCapabilityBits OBJECT-TYPE
SYNTAX IANAifMauAutoNegCapBits
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value that uniquely identifies the set of
capabilities of the local auto-negotiation
entity. Note that interfaces that support this
MIB may have capabilities that extend beyond the
scope of this MIB.
Note that the local auto-negotiation entity may
support some capabilities beyond the scope of
this MIB. This is indicated by returning the
bit value bOther in addition to any bit values
for standard capabilities that are listed in the
IANAifMauAutoNegCapBits TC."
Beili Standards Track [Page 33]
RFC 4836 MAU MIB April 2007
REFERENCE "[IEEE802.3], 30.6.1.1.5,
aAutoNegLocalTechnologyAbility."
::= { ifMauAutoNegEntry 9 }
ifMauAutoNegCapAdvertisedBits OBJECT-TYPE
SYNTAX IANAifMauAutoNegCapBits
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A value that uniquely identifies the set of
capabilities advertised by the local
auto-negotiation entity.
Capabilities in this object that are not
available in ifMauAutoNegCapabilityBits cannot
be enabled.
Note that the local auto-negotiation entity may
advertise some capabilities beyond the scope of
this MIB. This is indicated by returning the
bit value bOther in addition to any bit values
for standard capabilities that are listed in the
IANAifMauAutoNegCapBits TC."
REFERENCE "[IEEE802.3], 30.6.1.1.6,
aAutoNegAdvertisedTechnologyAbility."
::= { ifMauAutoNegEntry 10 }
ifMauAutoNegCapReceivedBits OBJECT-TYPE
SYNTAX IANAifMauAutoNegCapBits
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value that uniquely identifies the set of
capabilities received from the remote
auto-negotiation entity.
Note that interfaces that support this MIB may
be attached to remote auto-negotiation entities
that have capabilities beyond the scope of this
MIB. This is indicated by returning the bit
value bOther in addition to any bit values for
standard capabilities that are listed in the
IANAifMauAutoNegCapBits TC."
REFERENCE "[IEEE802.3], 30.6.1.1.7,
aAutoNegReceivedTechnologyAbility."
::= { ifMauAutoNegEntry 11 }
ifMauAutoNegRemoteFaultAdvertised OBJECT-TYPE
SYNTAX INTEGER {
noError(1),
offline(2),
Beili Standards Track [Page 34]
RFC 4836 MAU MIB April 2007
linkFailure(3),
autoNegError(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A value that identifies any local fault
indications that this MAU has detected and will
advertise at the next auto-negotiation
interaction for 1000Mbps MAUs."
REFERENCE "[IEEE802.3], 30.6.1.1.6,
aAutoNegAdvertisedTechnologyAbility."
::= { ifMauAutoNegEntry 12 }
ifMauAutoNegRemoteFaultReceived OBJECT-TYPE
SYNTAX INTEGER {
noError(1),
offline(2),
linkFailure(3),
autoNegError(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value that identifies any fault indications
received from the far end of a link by the
local auto-negotiation entity for 1000Mbps
MAUs."
REFERENCE "[IEEE802.3], 30.6.1.1.7,
aAutoNegReceivedTechnologyAbility."
::= { ifMauAutoNegEntry 13 }
--
-- The Basic Broadband MAU Table
--
broadMauBasicTable OBJECT-TYPE
SYNTAX SEQUENCE OF BroadMauBasicEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This entire table has been deprecated. There
have been no reported implementations of this
table, and it is unlikely that there ever will
be. IEEE recommends that broadband MAU types
should not be used for new installations.
Table of descriptive and status information
Beili Standards Track [Page 35]
RFC 4836 MAU MIB April 2007
about the broadband MAUs connected to
interfaces."
::= { dot3BroadMauBasicGroup 1 }
broadMauBasicEntry OBJECT-TYPE
SYNTAX BroadMauBasicEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
An entry in the table, containing information
about a single broadband MAU."
INDEX { broadMauIfIndex,
broadMauIndex
}
::= { broadMauBasicTable 1 }
BroadMauBasicEntry ::=
SEQUENCE {
broadMauIfIndex InterfaceIndex,
broadMauIndex Integer32,
broadMauXmtRcvSplitType INTEGER,
broadMauXmtCarrierFreq Integer32,
broadMauTranslationFreq Integer32
}
broadMauIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This variable uniquely identifies the interface
to which the MAU described by this entry is
connected."
REFERENCE "RFC 2863, ifIndex."
::= { broadMauBasicEntry 1 }
broadMauIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This variable uniquely identifies the MAU
connected to interface broadMauIfIndex that is
Beili Standards Track [Page 36]
RFC 4836 MAU MIB April 2007
described by this entry."
REFERENCE "[IEEE802.3], 30.5.1.1.1, aMAUID."
::= { broadMauBasicEntry 2 }
broadMauXmtRcvSplitType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
single(2),
dual(3)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This object indicates the type of frequency
multiplexing/cabling system used to separate the
transmit and receive paths for the 10BROAD36
MAU.
The value other(1) is returned if the split type
is not either single or dual.
The value single(2) indicates a single cable
system. The value dual(3) indicates a dual
cable system, offset normally zero."
REFERENCE "[IEEE802.3], 30.5.1.1.8, aBbMAUXmitRcvSplitType."
::= { broadMauBasicEntry 3 }
broadMauXmtCarrierFreq OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This variable indicates the transmit carrier
frequency of the 10BROAD36 MAU in MHz/4; that
is, in units of 250 kHz."
REFERENCE "[IEEE802.3], 30.5.1.1.9,
aBroadbandFrequencies.xmitCarrierFrequency."
::= { broadMauBasicEntry 4 }
broadMauTranslationFreq OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This variable indicates the translation offset
Beili Standards Track [Page 37]
RFC 4836 MAU MIB April 2007
frequency of the 10BROAD36 MAU in MHz/4; that
is, in units of 250 kHz."
REFERENCE "[IEEE802.3], 30.5.1.1.9,
aBroadbandFrequencies.translationFrequency."
::= { broadMauBasicEntry 5 }
-- Notifications for use by 802.3 MAUs
snmpDot3MauTraps OBJECT IDENTIFIER ::= { snmpDot3MauMgt 0 }
rpMauJabberTrap NOTIFICATION-TYPE
OBJECTS { rpMauJabberState }
STATUS current
DESCRIPTION "This trap is sent whenever a managed repeater
MAU enters the jabber state.
The agent MUST throttle the generation of
consecutive rpMauJabberTraps so that there is at
least a five-second gap between them."
REFERENCE "[IEEE802.3], 30.5.1.3.1, nJabber notification."
::= { snmpDot3MauTraps 1 }
ifMauJabberTrap NOTIFICATION-TYPE
OBJECTS { ifMauJabberState }
STATUS current
DESCRIPTION "This trap is sent whenever a managed interface
MAU enters the jabber state.
The agent MUST throttle the generation of
consecutive ifMauJabberTraps so that there is at
least a five-second gap between them."
REFERENCE "[IEEE802.3], 30.5.1.3.1, nJabber notification."
::= { snmpDot3MauTraps 2 }
-- Conformance information
mauModConf
OBJECT IDENTIFIER ::= { mauMod 1 }
mauModCompls
OBJECT IDENTIFIER ::= { mauModConf 1 }
mauModObjGrps
OBJECT IDENTIFIER ::= { mauModConf 2 }
mauModNotGrps
OBJECT IDENTIFIER ::= { mauModConf 3 }
-- Object groups
Beili Standards Track [Page 38]
RFC 4836 MAU MIB April 2007
mauRpGrpBasic OBJECT-GROUP
OBJECTS { rpMauGroupIndex,
rpMauPortIndex,
rpMauIndex,
rpMauType,
rpMauStatus,
rpMauMediaAvailable,
rpMauMediaAvailableStateExits,
rpMauJabberState,
rpMauJabberingStateEnters
}
STATUS current
DESCRIPTION "Basic conformance group for MAUs attached to
repeater ports. This group is also the
conformance specification for RFC 1515
implementations."
::= { mauModObjGrps 1 }
mauRpGrp100Mbs OBJECT-GROUP
OBJECTS { rpMauFalseCarriers }
STATUS current
DESCRIPTION "Conformance group for MAUs attached to
repeater ports with 100 Mb/s or greater
capability."
::= { mauModObjGrps 2 }
mauRpGrpJack OBJECT-GROUP
OBJECTS { rpJackType }
STATUS current
DESCRIPTION "Conformance group for MAUs attached to
repeater ports with managed jacks."
::= { mauModObjGrps 3 }
mauIfGrpBasic OBJECT-GROUP
OBJECTS { ifMauIfIndex,
ifMauIndex,
ifMauType,
ifMauStatus,
ifMauMediaAvailable,
ifMauMediaAvailableStateExits,
ifMauJabberState,
ifMauJabberingStateEnters
}
STATUS current
DESCRIPTION "Basic conformance group for MAUs attached to
interfaces. This group also provides a
conformance specification for RFC 1515
implementations."
Beili Standards Track [Page 39]
RFC 4836 MAU MIB April 2007
::= { mauModObjGrps 4 }
mauIfGrp100Mbs OBJECT-GROUP
OBJECTS { ifMauFalseCarriers,
ifMauTypeList,
ifMauDefaultType,
ifMauAutoNegSupported
}
STATUS deprecated
DESCRIPTION "********* THIS GROUP IS DEPRECATED **********
Conformance group for MAUs attached to
interfaces with 100 Mb/s capability.
This object group has been deprecated in favor
of mauIfGrpHighCapacity."
::= { mauModObjGrps 5 }
mauIfGrpJack OBJECT-GROUP
OBJECTS { ifJackType }
STATUS current
DESCRIPTION "Conformance group for MAUs attached to
interfaces with managed jacks."
::= { mauModObjGrps 6 }
mauIfGrpAutoNeg OBJECT-GROUP
OBJECTS { ifMauAutoNegAdminStatus,
ifMauAutoNegRemoteSignaling,
ifMauAutoNegConfig,
ifMauAutoNegCapability,
ifMauAutoNegCapAdvertised,
ifMauAutoNegCapReceived,
ifMauAutoNegRestart
}
STATUS deprecated
DESCRIPTION "********* THIS GROUP IS DEPRECATED **********
Conformance group for MAUs attached to
interfaces with managed auto-negotiation.
This object group has been deprecated in favor
of mauIfGrpAutoNeg2."
::= { mauModObjGrps 7 }
mauBroadBasic OBJECT-GROUP
OBJECTS { broadMauIfIndex,
broadMauIndex,
Beili Standards Track [Page 40]
RFC 4836 MAU MIB April 2007
broadMauXmtRcvSplitType,
broadMauXmtCarrierFreq,
broadMauTranslationFreq
}
STATUS deprecated
DESCRIPTION "********* THIS GROUP IS DEPRECATED **********
Conformance group for broadband MAUs attached
to interfaces.
This object group is deprecated. There have
been no reported implementations of this group,
and it was felt to be unlikely that there will
be any future implementations."
::= { mauModObjGrps 8 }
mauIfGrpHighCapacity OBJECT-GROUP
OBJECTS { ifMauFalseCarriers,
ifMauTypeListBits,
ifMauDefaultType,
ifMauAutoNegSupported
}
STATUS current
DESCRIPTION "Conformance group for MAUs attached to
interfaces with 100 Mb/s or greater capability."
::= { mauModObjGrps 9 }
mauIfGrpAutoNeg2 OBJECT-GROUP
OBJECTS { ifMauAutoNegAdminStatus,
ifMauAutoNegRemoteSignaling,
ifMauAutoNegConfig,
ifMauAutoNegCapabilityBits,
ifMauAutoNegCapAdvertisedBits,
ifMauAutoNegCapReceivedBits,
ifMauAutoNegRestart
}
STATUS current
DESCRIPTION "Conformance group for MAUs attached to
interfaces with managed auto-negotiation."
::= { mauModObjGrps 10 }
mauIfGrpAutoNeg1000Mbps OBJECT-GROUP
OBJECTS { ifMauAutoNegRemoteFaultAdvertised,
ifMauAutoNegRemoteFaultReceived
}
STATUS current
DESCRIPTION "Conformance group for 1000Mbps MAUs attached to
interfaces with managed auto-negotiation."
::= { mauModObjGrps 11 }
Beili Standards Track [Page 41]
RFC 4836 MAU MIB April 2007
mauIfGrpHCStats OBJECT-GROUP
OBJECTS { ifMauHCFalseCarriers }
STATUS current
DESCRIPTION "Conformance for high capacity statistics for
MAUs attached to interfaces."
::= { mauModObjGrps 12 }
-- Notification groups
rpMauNotifications NOTIFICATION-GROUP
NOTIFICATIONS { rpMauJabberTrap }
STATUS current
DESCRIPTION "Notifications for repeater MAUs."
::= { mauModNotGrps 1 }
ifMauNotifications NOTIFICATION-GROUP
NOTIFICATIONS { ifMauJabberTrap }
STATUS current
DESCRIPTION "Notifications for interface MAUs."
::= { mauModNotGrps 2 }
-- Compliances
mauModRpCompl MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "******** THIS COMPLIANCE IS DEPRECATED ********
Compliance for MAUs attached to repeater
ports.
This compliance is deprecated and replaced by
mauModRpCompl2, which corrects an oversight by
allowing rpMauStatus to be implemented
read-only."
MODULE -- this module
MANDATORY-GROUPS { mauRpGrpBasic }
GROUP mauRpGrp100Mbs
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have 100Mb/s or
greater capability."
GROUP mauRpGrpJack
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have one or more
external jacks."
GROUP rpMauNotifications
Beili Standards Track [Page 42]
RFC 4836 MAU MIB April 2007
DESCRIPTION "Implementation of this group is recommended
for MAUs attached to repeater ports."
::= { mauModCompls 1 }
mauModIfCompl MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "******** THIS COMPLIANCE IS DEPRECATED ********
Compliance for MAUs attached to interfaces.
This compliance is deprecated and replaced by
mauModIfCompl2."
MODULE -- this module
MANDATORY-GROUPS { mauIfGrpBasic }
GROUP mauIfGrp100Mbs
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have 100Mb/s
capability."
GROUP mauIfGrpJack
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have one or more
external jacks."
GROUP mauIfGrpAutoNeg
DESCRIPTION "Implementation of this group is mandatory
for MAUs that support managed
auto-negotiation."
GROUP mauBroadBasic
DESCRIPTION "Implementation of this group is mandatory
for broadband MAUs."
GROUP ifMauNotifications
DESCRIPTION "Implementation of this group is recommended
for MAUs attached to interfaces."
::= { mauModCompls 2 }
mauModIfCompl2 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "******** THIS COMPLIANCE IS DEPRECATED ********
Compliance for MAUs attached to interfaces.
This compliance is deprecated and replaced by
mauModIfCompl3."
Beili Standards Track [Page 43]
RFC 4836 MAU MIB April 2007
MODULE -- this module
MANDATORY-GROUPS { mauIfGrpBasic }
GROUP mauIfGrpHighCapacity
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have 100Mb/s
or greater capability."
GROUP mauIfGrpJack
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have one or more
external jacks."
GROUP mauIfGrpAutoNeg2
DESCRIPTION "Implementation of this group is mandatory
for MAUs that support managed
auto-negotiation."
GROUP mauIfGrpAutoNeg1000Mbps
DESCRIPTION "Implementation of this group is mandatory
for MAUs that have 1000Mb/s or greater
capability and support managed
auto-negotiation."
GROUP ifMauNotifications
DESCRIPTION "Implementation of this group is recommended
for MAUs attached to interfaces."
OBJECT ifMauStatus
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
::= { mauModCompls 3 }
mauModRpCompl2 MODULE-COMPLIANCE
STATUS current
DESCRIPTION "Compliance for MAUs attached to repeater
ports.
Note that compliance with this compliance
statement requires compliance with the
snmpRptrModCompl MODULE-COMPLIANCE statement of
the SNMP-REPEATER-MIB (RFC 2108)."
MODULE -- this module
MANDATORY-GROUPS { mauRpGrpBasic }
GROUP mauRpGrp100Mbs
Beili Standards Track [Page 44]
RFC 4836 MAU MIB April 2007
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have 100Mb/s or
greater capability."
GROUP mauRpGrpJack
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have one or more
external jacks."
GROUP rpMauNotifications
DESCRIPTION "Implementation of this group is recommended
for MAUs attached to repeater ports."
OBJECT rpMauStatus
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
::= { mauModCompls 4 }
mauModIfCompl3 MODULE-COMPLIANCE
STATUS current
DESCRIPTION "Compliance for MAUs attached to interfaces.
Note that compliance with this compliance
statement requires compliance with the
ifCompliance3 MODULE-COMPLIANCE statement of the
IF-MIB (RFC 2863) and the dot3Compliance2
MODULE-COMPLIANCE statement of the
EtherLike-MIB (RFC3635)."
MODULE -- this module
MANDATORY-GROUPS { mauIfGrpBasic }
GROUP mauIfGrpHighCapacity
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have 100Mb/s
or greater capability."
GROUP mauIfGrpHCStats
DESCRIPTION "Implementation of this group is mandatory
for MAUs that have 1000Mb/s capacity, and
is recommended for MAUs that have 100Mb/s
capacity."
GROUP mauIfGrpJack
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have one or more
external jacks."
Beili Standards Track [Page 45]
RFC 4836 MAU MIB April 2007
GROUP mauIfGrpAutoNeg2
DESCRIPTION "Implementation of this group is mandatory
for MAUs that support managed
auto-negotiation."
GROUP mauIfGrpAutoNeg1000Mbps
DESCRIPTION "Implementation of this group is mandatory
for MAUs that have 1000Mb/s or greater
capability and support managed
auto-negotiation."
GROUP ifMauNotifications
DESCRIPTION "Implementation of this group is recommended
for MAUs attached to interfaces."
OBJECT ifMauStatus
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
::= { mauModCompls 5 }
END
5. IANA-Maintained MAU TC Definitions
IANA-MAU-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-IDENTITY, mib-2
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC
;
ianaMauMIB MODULE-IDENTITY
LAST-UPDATED "200704210000Z" -- April 21, 2007
ORGANIZATION "IANA"
CONTACT-INFO " Internet Assigned Numbers Authority
Postal: ICANN
4676 Admiralty Way, Suite 330
Marina del Rey, CA 90292
Tel: +1-310-823-9358
EMail: iana@iana.org"
DESCRIPTION
"This MIB module defines dot3MauType OBJECT-IDENTITIES and
IANAifMauListBits, IANAifMauMediaAvailable,
IANAifMauAutoNegCapBits, and IANAifJackType
Beili Standards Track [Page 46]
RFC 4836 MAU MIB April 2007
TEXTUAL-CONVENTIONs, specifying enumerated values of the
ifMauTypeListBits, ifMauMediaAvailable / rpMauMediaAvailable,
ifMauAutoNegCapabilityBits / ifMauAutoNegCapAdvertisedBits /
ifMauAutoNegCapReceivedBits and ifJackType / rpJackType objects
respectively, defined in the MAU-MIB.
It is intended that each new MAU type, Media Availability
state, Auto Negotiation capability and/or Jack type defined by
the IEEE 802.3 working group and approved for publication in a
revision of IEEE Std 802.3 will be added to this MIB module,
provided that it is suitable for being managed by the base
objects in the MAU-MIB. An Expert Review, as defined in
RFC 2434 [RFC2434], is REQUIRED for such additions.
The following reference is used throughout this MIB module:
[IEEE802.3] refers to:
IEEE Std 802.3, 2005 Edition: 'IEEE Standard for
Information technology - Telecommunications and information
exchange between systems - Local and metropolitan area
networks - Specific requirements -
Part 3: Carrier sense multiple access with collision
detection (CSMA/CD) access method and physical layer
specifications'.
This reference should be updated as appropriate when new
MAU types, Media Availability states, Auto Negotiation
capabilities, and/or Jack types are added to this MIB module.
Copyright (C) The IETF Trust (2007).
The initial version of this MIB module was published in
RFC 4836; for full legal notices see the RFC itself.
Supplementary information may be available at:
http://www.ietf.org/copyrights/ianamib.html"
REVISION "200704210000Z" -- April 21, 2007
DESCRIPTION "Initial version of this MIB as published in
RFC 4836."
::= { mib-2 154 }
-- Textual Conventions
IANAifMauTypeListBits ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used as the syntax of the ifMauTypeListBits
object in the (updated) definition of MAU-MIB's ifMauTable.
Beili Standards Track [Page 47]
RFC 4836 MAU MIB April 2007
The most recent version of this textual convention is available
in the online version of this MIB module on the IANA web site.
Requests for new values should be made to IANA via email
(iana@iana.org).
Note that changes in this textual convention SHALL be
synchronized with relevant changes in the dot3MauType
OBJECT-IDENTITIES."
REFERENCE
"[IEEE802.3], Section 30.5.1.1.2"
SYNTAX BITS {
bOther(0), -- other or unknown
bAUI(1), -- AUI
b10base5(2), -- 10BASE-5
bFoirl(3), -- FOIRL
b10base2(4), -- 10BASE-2
b10baseT(5), -- 10BASE-T duplex mode unknown
b10baseFP(6), -- 10BASE-FP
b10baseFB(7), -- 10BASE-FB
b10baseFL(8), -- 10BASE-FL duplex mode unknown
b10broad36(9), -- 10BROAD36
b10baseTHD(10), -- 10BASE-T half duplex mode
b10baseTFD(11), -- 10BASE-T full duplex mode
b10baseFLHD(12), -- 10BASE-FL half duplex mode
b10baseFLFD(13), -- 10BASE-FL full duplex mode
b100baseT4(14), -- 100BASE-T4
b100baseTXHD(15), -- 100BASE-TX half duplex mode
b100baseTXFD(16), -- 100BASE-TX full duplex mode
b100baseFXHD(17), -- 100BASE-FX half duplex mode
b100baseFXFD(18), -- 100BASE-FX full duplex mode
b100baseT2HD(19), -- 100BASE-T2 half duplex mode
b100baseT2FD(20), -- 100BASE-T2 full duplex mode
b1000baseXHD(21), -- 1000BASE-X half duplex mode
b1000baseXFD(22), -- 1000BASE-X full duplex mode
b1000baseLXHD(23), -- 1000BASE-LX half duplex mode
b1000baseLXFD(24), -- 1000BASE-LX full duplex mode
b1000baseSXHD(25), -- 1000BASE-SX half duplex mode
b1000baseSXFD(26), -- 1000BASE-SX full duplex mode
b1000baseCXHD(27), -- 1000BASE-CX half duplex mode
b1000baseCXFD(28), -- 1000BASE-CX full duplex mode
b1000baseTHD(29), -- 1000BASE-T half duplex mode
b1000baseTFD(30), -- 1000BASE-T full duplex mode
b10GbaseX(31), -- 10GBASE-X
b10GbaseLX4(32), -- 10GBASE-LX4
Beili Standards Track [Page 48]
RFC 4836 MAU MIB April 2007
b10GbaseR(33), -- 10GBASE-R
b10GbaseER(34), -- 10GBASE-ER
b10GbaseLR(35), -- 10GBASE-LR
b10GbaseSR(36), -- 10GBASE-SR
b10GbaseW(37), -- 10GBASE-W
b10GbaseEW(38), -- 10GBASE-EW
b10GbaseLW(39), -- 10GBASE-LW
b10GbaseSW(40), -- 10GBASE-SW
-- new since RFC 3636
b10GbaseCX4(41), -- 10GBASE-CX4
b2BaseTL(42), -- 2BASE-TL
b10PassTS(43), -- 10PASS-TS
b100BaseBX10D(44), -- 100BASE-BX10D
b100BaseBX10U(45), -- 100BASE-BX10U
b100BaseLX10(46), -- 100BASE-LX10
b1000BaseBX10D(47), -- 1000BASE-BX10D
b1000BaseBX10U(48), -- 1000BASE-BX10U
b1000BaseLX10(49), -- 1000BASE-LX10
b1000BasePX10D(50), -- 1000BASE-PX10D
b1000BasePX10U(51), -- 1000BASE-PX10U
b1000BasePX20D(52), -- 1000BASE-PX20D
b1000BasePX20U(53) -- 1000BASE-PX20U
}
IANAifMauMediaAvailable ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used as the syntax of the
ifMauMediaAvailable and rpMauMediaAvailable objects in the
(updated) definition of MAU-MIB's ifMauTable and rpMauTable
respectively.
Possible values are:
other(1) - undefined (not listed below)
unknown(2) - MAU's true state is unknown; e.g.,
during initialization
available(3) - link, light, or loopback is normal
notAvailable(4) - link loss, low light, or no loopback
remoteFault(5) - a fault has been detected at the
remote end of the link. This value
applies to 10BASE-FB, 100BASE-T4 Far
End Fault Indication and non-specified
remote faults from a system running
auto-negotiation
invalidSignal(6) - invalid signal has been received from
the other end of the link, 10BASE-FB
only
remoteJabber(7) - remote fault, due to jabber
Beili Standards Track [Page 49]
RFC 4836 MAU MIB April 2007
remoteLinkLoss(8) - remote fault, due to link loss
remoteTest(9) - remote fault, due to test
offline(10) - offline, Clause 37 Auto-Negotiation
only
autoNegError(11) - Auto-Negotiation Error, Clause 37
Auto-Negotiation only
pmdLinkFault(12) - PMA/PMD receive link fault. In case
of PAF (2BASE-TL / 10PASS-TS PHYs),
all PMEs in the aggregation group have
detected a link fault
wisFrameLoss(13) - WIS loss of frame, 10GBASE-W only
wisSignalLoss(14) - WIS loss of signal, 10GBASE-W only
pcsLinkFault(15) - PCS receive link fault
excessiveBER(16) - PCS Bit Error Ratio monitor
reporting excessive error ratio
dxsLinkFault(17) - DTE XGXS receive link fault, XAUI only
pxsLinkFault(18) - PHY XGXS receive link fault, XAUI only
availableReduced(19) - link normal, reduced bandwidth,
2BASE-TL / 10PASS-TS only
ready(20) - at least one PME in the aggregation
group is detecting handshake tones,
2BASE-TL / 10PASS-TS only
If the MAU is a 10M b/s link or fiber type (FOIRL, 10BASE-T,
10BASE-F), then this is equivalent to the link test fail
state/low light function. For an AUI, 10BASE2, 10BASE5, or
10BROAD36 MAU, this indicates whether loopback is detected on
the DI circuit. The value of this attribute persists between
packets for MAU types AUI, 10BASE5, 10BASE2, 10BROAD36, and
10BASEFP.
At power-up or following a reset, the Media Available state
will be unknown(2) for AUI, 10BASE5, 10BASE2, 10BROAD36, and
10BASE-FP MAUs. For these MAUs loopback will be tested on each
transmission during which no collision is detected.
If DI is receiving input when DO returns to IDL after a
transmission and there has been no collision during the
transmission, then loopback will be detected. The Media
Available state will only change during noncollided
transmissions for AUI, 10BASE2, 10BASE5, 10BROAD36, and
10BASE-FP MAUs.
For 100BASE-T2, 100BASE-T4, 100BASE-TX, 100BASE-FX,
100BASE-LX10, and 100BASE-BX10 PHYs the enumerations match the
states within the link integrity state diagram.
Any MAU that implements management of [IEEE802.3] Clause
28 Auto-Negotiation, will map remote fault indication to
remoteFault(5).
Beili Standards Track [Page 50]
RFC 4836 MAU MIB April 2007
Any MAU that implements management of Clause 37
Auto-Negotiation, will map the received RF1 and RF2 bits as
follows: Offline maps to offline(10), Link_Failure maps to
remoteFault(5), and Auto-Negotiation Error maps to
autoNegError(11).
The value remoteFault(5) applies to 10BASE-FB remote
fault indication, the 100BASE-X far-end fault indication, and
nonspecified remote faults from a system running Clause 28
Auto-Negotiation.
The value remoteJabber(7), remoteLink loss(8), or remoteTest(9)
SHOULD be used instead of remoteFault(5) where the reason for
remote fault is identified in the remote signaling protocol.
Where a Clause 22 MII or Clause 35 GMII is present, a logic
one in the remote fault bit maps to the value remoteFault(5),
a logic zero in the link status bit maps to the enumeration
notAvailable(4). The value notAvailable(4) takes precedence
over remoteFault(5).
For 2BASE-TL and 10PASS-TS PHYs, the value unknown(2) maps to
the condition where the PHY (PCS with connected PMEs) is
initializing, the value ready(20) maps to the condition where
the interface is down and at least one PME in the aggregation
group is ready for handshake, the value available(3) maps to
the condition where all the PMEs in the aggregation group are
up, the value notAvailable(4) maps to the condition where all
the PMEs in the aggregation group are down and no handshake
tones are detected, the value availableReduced(19) maps to the
condition where the interface is up, a link fault is detected
at the receive direction by one or more PMEs in the
aggregation group, but at least one PME is up and the
enumeration pmdLinkFault(12) maps to the condition where a link
fault is detected at the receive direction by all of the PMEs
in the aggregation group.
For 10 Gb/s the enumerations map to value of the link_fault
variable within the Link Fault Signaling state diagram
as follows: the value OK maps to the value available(3),
the value Local Fault maps to the value notAvailable(4),
and the value Remote Fault maps to the value remoteFault(5).
The value pmdLinkFault(12), wisFrameLoss(13),
wisSignalLoss(14), pcsLinkFault(15), excessiveBER(16), or
dxsLinkFault(17) SHOULD be used instead of the value
notAvailable(4), where the reason for the Local Fault state can
be identified through the use of the Clause 45 MDIO Interface.
Where multiple reasons for the Local Fault state can be
identified, only the highest precedence error SHOULD be
Beili Standards Track [Page 51]
RFC 4836 MAU MIB April 2007
reported. This precedence in descending order is as follows:
pxsLinkFault
pmdLinkFault
wisFrameLoss
wisSignalLoss
pcsLinkFault
excessiveBER
dxsLinkFault.
Where a Clause 45 MDIO interface is present a logic zero in
the PMA/PMD Receive link status bit ([IEEE802.3]
Section 45.2.1.2.2) maps to the value pmdLinkFault(12),
logic one in the LOF status bit (Section 45.2.2.10.4) maps
to the value wisFrameLoss(13), a logic one in the LOS
status bit (Section 45.2.2.10.5) maps to the value
wisSignalLoss, a logic zero in the PCS Receive
link status bit (Section 45.2.3.2.2) maps to the value
pcsLinkFault(15), a logic one in the 10GBASE-R PCS Latched
high BER status bit (Section 45.2.3.12.2) maps to the value
excessiveBER, a logic zero in the DTE XS receive link status
bit (Section 45.2.5.2.2) maps to the value dxsLinkFault(17)
and a logic zero in the PHY XS transmit link status bit
(Section 45.2.4.2.2) maps to the value pxsLinkFault(18).
The most recent version of this textual convention is available
in the online version of this MIB module on the IANA web site.
Requests for new values should be made to IANA via email
(iana@iana.org)."
REFERENCE
"[IEEE802.3], Section 30.5.1.1.4"
SYNTAX INTEGER {
other(1),
unknown(2),
available(3),
notAvailable(4),
remoteFault(5),
invalidSignal(6),
remoteJabber(7),
remoteLinkLoss(8),
remoteTest(9),
offline(10),
autoNegError(11),
pmdLinkFault(12),
wisFrameLoss(13),
wisSignalLoss(14),
pcsLinkFault(15),
Beili Standards Track [Page 52]
RFC 4836 MAU MIB April 2007
excessiveBER(16),
dxsLinkFault(17),
pxsLinkFault(18),
availableReduced(19),
ready(20)
}
IANAifMauAutoNegCapBits ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used as the syntax of the
ifMauAutoNegCapabilityBits, ifMauAutoNegCapAdvertisedBits, and
ifMauAutoNegCapReceivedBits objects in the (updated) definition
of MAU-MIB's ifMauAutoNegTable.
The most recent version of this textual convention is available
in the online version of this MIB module on the IANA web site.
Requests for new values should be made to IANA via email
(iana@iana.org)."
REFERENCE
"[IEEE802.3], Section 30.6.1.1.5"
SYNTAX BITS {
bOther(0), -- other or unknown
b10baseT(1), -- 10BASE-T half duplex mode
b10baseTFD(2), -- 10BASE-T full duplex mode
b100baseT4(3), -- 100BASE-T4
b100baseTX(4), -- 100BASE-TX half duplex mode
b100baseTXFD(5), -- 100BASE-TX full duplex mode
b100baseT2(6), -- 100BASE-T2 half duplex mode
b100baseT2FD(7), -- 100BASE-T2 full duplex mode
bFdxPause(8), -- PAUSE for full-duplex links
bFdxAPause(9), -- Asymmetric PAUSE for full-duplex
-- links
bFdxSPause(10), -- Symmetric PAUSE for full-duplex
-- links
bFdxBPause(11), -- Asymmetric and Symmetric PAUSE for
-- full-duplex links
b1000baseX(12), -- 1000BASE-X, -LX, -SX, -CX half
-- duplex mode
b1000baseXFD(13), -- 1000BASE-X, -LX, -SX, -CX full
-- duplex mode
b1000baseT(14), -- 1000BASE-T half duplex mode
b1000baseTFD(15) -- 1000BASE-T full duplex mode
}
IANAifJackType ::= TEXTUAL-CONVENTION
STATUS current
Beili Standards Track [Page 53]
RFC 4836 MAU MIB April 2007
DESCRIPTION
"Common enumeration values for repeater and interface MAU
jack types. This data type is used as the syntax of the
ifJackType and rpJackType objects in the (updated) definition
of MAU-MIB's ifJackTable and rpJackTable respectively.
Possible values are:
other(1) - undefined or unknown
rj45(2) - RJ45
rj45S(3) - RJ45 shielded
db9(4) - DB9
bnc(5) - BNC
fAUI(6) - AUI female
mAUI(7) - AUI male
fiberSC(8) - SC fiber
fiberMIC(9) - MIC fiber
fiberST(10) - ST fiber
telco(11) - Telco
mtrj(12) - MT-RJ fiber
hssdc(13) - fiber channel style-2
fiberLC(14) - LC fiber
cx4(15) - IB4X for 10GBASE-CX4
The most recent version of this textual convention is available
in the online version of this MIB module on the IANA web site.
Requests for new values should be made to IANA via email
(iana@iana.org)."
SYNTAX INTEGER {
other(1),
rj45(2),
rj45S(3),
db9(4),
bnc(5),
fAUI(6),
mAUI(7),
fiberSC(8),
fiberMIC(9),
fiberST(10),
telco(11),
mtrj(12),
hssdc(13),
fiberLC(14),
-- new since RFC 3636
cx4(15)
}
-- OBJECT IDENTITIES for MAU types
Beili Standards Track [Page 54]
RFC 4836 MAU MIB April 2007
-- (see rpMauType and ifMauType of MAU-MIB for usage)
-- The following definitions has been moved from RFC 3636 and
-- no longer appear in its revision.
dot3MauType OBJECT IDENTIFIER ::= { mib-2 snmpDot3MauMgt(26) 4 }
dot3MauTypeAUI OBJECT-IDENTITY
STATUS current
DESCRIPTION "no internal MAU, view from AUI"
REFERENCE "[IEEE802.3], Section 7"
::= { dot3MauType 1 }
dot3MauType10Base5 OBJECT-IDENTITY
STATUS current
DESCRIPTION "thick coax MAU"
REFERENCE "[IEEE802.3], Section 7"
::= { dot3MauType 2 }
dot3MauTypeFoirl OBJECT-IDENTITY
STATUS current
DESCRIPTION "FOIRL MAU"
REFERENCE "[IEEE802.3], Section 9.9"
::= { dot3MauType 3 }
dot3MauType10Base2 OBJECT-IDENTITY
STATUS current
DESCRIPTION "thin coax MAU"
REFERENCE "[IEEE802.3], Section 10"
::= { dot3MauType 4 }
dot3MauType10BaseT OBJECT-IDENTITY
STATUS current
DESCRIPTION "UTP MAU.
Note that it is strongly recommended that
agents return either dot3MauType10BaseTHD or
dot3MauType10BaseTFD if the duplex mode is
known. However, management applications should
be prepared to receive this MAU type value from
older agent implementations."
REFERENCE "[IEEE802.3], Section 14"
::= { dot3MauType 5 }
dot3MauType10BaseFP OBJECT-IDENTITY
STATUS current
DESCRIPTION "passive fiber MAU"
REFERENCE "[IEEE802.3], Section 16"
::= { dot3MauType 6 }
Beili Standards Track [Page 55]
RFC 4836 MAU MIB April 2007
dot3MauType10BaseFB OBJECT-IDENTITY
STATUS current
DESCRIPTION "sync fiber MAU"
REFERENCE "[IEEE802.3], Section 17"
::= { dot3MauType 7 }
dot3MauType10BaseFL OBJECT-IDENTITY
STATUS current
DESCRIPTION "async fiber MAU.
Note that it is strongly recommended that
agents return either dot3MauType10BaseFLHD or
dot3MauType10BaseFLFD if the duplex mode is
known. However, management applications should
be prepared to receive this MAU type value from
older agent implementations."
REFERENCE "[IEEE802.3], Section 18"
::= { dot3MauType 8 }
dot3MauType10Broad36 OBJECT-IDENTITY
STATUS current
DESCRIPTION "broadband DTE MAU.
Note that 10BROAD36 MAUs can be attached to
interfaces but not to repeaters."
REFERENCE "[IEEE802.3], Section 11"
::= { dot3MauType 9 }
------ new since RFC 1515:
dot3MauType10BaseTHD OBJECT-IDENTITY
STATUS current
DESCRIPTION "UTP MAU, half duplex mode"
REFERENCE "[IEEE802.3], Section 14"
::= { dot3MauType 10 }
dot3MauType10BaseTFD OBJECT-IDENTITY
STATUS current
DESCRIPTION "UTP MAU, full duplex mode"
REFERENCE "[IEEE802.3], Section 14"
::= { dot3MauType 11 }
dot3MauType10BaseFLHD OBJECT-IDENTITY
STATUS current
DESCRIPTION "async fiber MAU, half duplex mode"
REFERENCE "[IEEE802.3], Section 18"
::= { dot3MauType 12 }
dot3MauType10BaseFLFD OBJECT-IDENTITY
STATUS current
DESCRIPTION "async fiber MAU, full duplex mode"
Beili Standards Track [Page 56]
RFC 4836 MAU MIB April 2007
REFERENCE "[IEEE802.3], Section 18"
::= { dot3MauType 13 }
dot3MauType100BaseT4 OBJECT-IDENTITY
STATUS current
DESCRIPTION "4 pair category 3 UTP"
REFERENCE "[IEEE802.3], Section 23"
::= { dot3MauType 14 }
dot3MauType100BaseTXHD OBJECT-IDENTITY
STATUS current
DESCRIPTION "2 pair category 5 UTP, half duplex mode"
REFERENCE "[IEEE802.3], Section 25"
::= { dot3MauType 15 }
dot3MauType100BaseTXFD OBJECT-IDENTITY
STATUS current
DESCRIPTION "2 pair category 5 UTP, full duplex mode"
REFERENCE "[IEEE802.3], Section 25"
::= { dot3MauType 16 }
dot3MauType100BaseFXHD OBJECT-IDENTITY
STATUS current
DESCRIPTION "X fiber over PMT, half duplex mode"
REFERENCE "[IEEE802.3], Section 26"
::= { dot3MauType 17 }
dot3MauType100BaseFXFD OBJECT-IDENTITY
STATUS current
DESCRIPTION "X fiber over PMT, full duplex mode"
REFERENCE "[IEEE802.3], Section 26"
::= { dot3MauType 18 }
dot3MauType100BaseT2HD OBJECT-IDENTITY
STATUS current
DESCRIPTION "2 pair category 3 UTP, half duplex mode"
REFERENCE "[IEEE802.3], Section 32"
::= { dot3MauType 19 }
dot3MauType100BaseT2FD OBJECT-IDENTITY
STATUS current
DESCRIPTION "2 pair category 3 UTP, full duplex mode"
REFERENCE "[IEEE802.3], Section 32"
::= { dot3MauType 20 }
------ new since RFC 2239:
dot3MauType1000BaseXHD OBJECT-IDENTITY
STATUS current
Beili Standards Track [Page 57]
RFC 4836 MAU MIB April 2007
DESCRIPTION "PCS/PMA, unknown PMD, half duplex mode"
REFERENCE "[IEEE802.3], Section 36"
::= { dot3MauType 21 }
dot3MauType1000BaseXFD OBJECT-IDENTITY
STATUS current
DESCRIPTION "PCS/PMA, unknown PMD, full duplex mode"
REFERENCE "[IEEE802.3], Section 36"
::= { dot3MauType 22 }
dot3MauType1000BaseLXHD OBJECT-IDENTITY
STATUS current
DESCRIPTION "Fiber over long-wavelength laser, half duplex
mode"
REFERENCE "[IEEE802.3], Section 38"
::= { dot3MauType 23 }
dot3MauType1000BaseLXFD OBJECT-IDENTITY
STATUS current
DESCRIPTION "Fiber over long-wavelength laser, full duplex
mode"
REFERENCE "[IEEE802.3], Section 38"
::= { dot3MauType 24 }
dot3MauType1000BaseSXHD OBJECT-IDENTITY
STATUS current
DESCRIPTION "Fiber over short-wavelength laser, half
duplex mode"
REFERENCE "[IEEE802.3], Section 38"
::= { dot3MauType 25 }
dot3MauType1000BaseSXFD OBJECT-IDENTITY
STATUS current
DESCRIPTION "Fiber over short-wavelength laser, full
duplex mode"
REFERENCE "[IEEE802.3], Section 38"
::= { dot3MauType 26 }
dot3MauType1000BaseCXHD OBJECT-IDENTITY
STATUS current
DESCRIPTION "Copper over 150-Ohm balanced cable, half
duplex mode"
REFERENCE "[IEEE802.3], Section 39"
::= { dot3MauType 27 }
dot3MauType1000BaseCXFD OBJECT-IDENTITY
STATUS current
DESCRIPTION "Copper over 150-Ohm balanced cable, full
Beili Standards Track [Page 58]
RFC 4836 MAU MIB April 2007
duplex mode"
REFERENCE "[IEEE802.3], Section 39"
::= { dot3MauType 28 }
dot3MauType1000BaseTHD OBJECT-IDENTITY
STATUS current
DESCRIPTION "Four-pair Category 5 UTP, half duplex mode"
REFERENCE "[IEEE802.3], Section 40"
::= { dot3MauType 29 }
dot3MauType1000BaseTFD OBJECT-IDENTITY
STATUS current
DESCRIPTION "Four-pair Category 5 UTP, full duplex mode"
REFERENCE "[IEEE802.3], Section 40"
::= { dot3MauType 30 }
------ new since RFC 2668:
dot3MauType10GigBaseX OBJECT-IDENTITY
STATUS current
DESCRIPTION "X PCS/PMA, unknown PMD."
REFERENCE "[IEEE802.3], Section 48"
::= { dot3MauType 31 }
dot3MauType10GigBaseLX4 OBJECT-IDENTITY
STATUS current
DESCRIPTION "X fiber over WWDM optics"
REFERENCE "[IEEE802.3], Section 53"
::= { dot3MauType 32 }
dot3MauType10GigBaseR OBJECT-IDENTITY
STATUS current
DESCRIPTION "R PCS/PMA, unknown PMD."
REFERENCE "[IEEE802.3], Section 49"
::= { dot3MauType 33 }
dot3MauType10GigBaseER OBJECT-IDENTITY
STATUS current
DESCRIPTION "R fiber over 1550 nm optics"
REFERENCE "[IEEE802.3], Section 52"
::= { dot3MauType 34 }
dot3MauType10GigBaseLR OBJECT-IDENTITY
STATUS current
DESCRIPTION "R fiber over 1310 nm optics"
REFERENCE "[IEEE802.3], Section 52"
::= { dot3MauType 35 }
dot3MauType10GigBaseSR OBJECT-IDENTITY
Beili Standards Track [Page 59]
RFC 4836 MAU MIB April 2007
STATUS current
DESCRIPTION "R fiber over 850 nm optics"
REFERENCE "[IEEE802.3], Section 52"
::= { dot3MauType 36 }
dot3MauType10GigBaseW OBJECT-IDENTITY
STATUS current
DESCRIPTION "W PCS/PMA, unknown PMD."
REFERENCE "[IEEE802.3], Section 49 and 50"
::= { dot3MauType 37 }
dot3MauType10GigBaseEW OBJECT-IDENTITY
STATUS current
DESCRIPTION "W fiber over 1550 nm optics"
REFERENCE "[IEEE802.3], Section 52"
::= { dot3MauType 38 }
dot3MauType10GigBaseLW OBJECT-IDENTITY
STATUS current
DESCRIPTION "W fiber over 1310 nm optics"
REFERENCE "[IEEE802.3], Section 52"
::= { dot3MauType 39 }
dot3MauType10GigBaseSW OBJECT-IDENTITY
STATUS current
DESCRIPTION "W fiber over 850 nm optics"
REFERENCE "[IEEE802.3], Section 52"
::= { dot3MauType 40 }
------ new since RFC 3636:
dot3MauType10GigBaseCX4 OBJECT-IDENTITY
STATUS current
DESCRIPTION "X copper over 8 pair 100-Ohm balanced cable"
REFERENCE "[IEEE802.3], Section 54"
::= { dot3MauType 41 }
dot3MauType2BaseTL OBJECT-IDENTITY
STATUS current
DESCRIPTION "Voice grade UTP copper, up to 2700m, optional PAF"
REFERENCE "[IEEE802.3], Sections 61 and 63"
::= { dot3MauType 42 }
dot3MauType10PassTS OBJECT-IDENTITY
STATUS current
DESCRIPTION "Voice grade UTP copper, up to 750m, optional PAF"
REFERENCE "[IEEE802.3], Sections 61 and 62"
::= { dot3MauType 43 }
Beili Standards Track [Page 60]
RFC 4836 MAU MIB April 2007
dot3MauType100BaseBX10D OBJECT-IDENTITY
STATUS current
DESCRIPTION "One single-mode fiber OLT, long wavelength, 10km"
REFERENCE "[IEEE802.3], Section 58"
::= { dot3MauType 44 }
dot3MauType100BaseBX10U OBJECT-IDENTITY
STATUS current
DESCRIPTION "One single-mode fiber ONU, long wavelength, 10km"
REFERENCE "[IEEE802.3], Section 58"
::= { dot3MauType 45 }
dot3MauType100BaseLX10 OBJECT-IDENTITY
STATUS current
DESCRIPTION "Two single-mode fibers, long wavelength, 10km"
REFERENCE "[IEEE802.3], Section 58"
::= { dot3MauType 46 }
dot3MauType1000BaseBX10D OBJECT-IDENTITY
STATUS current
DESCRIPTION "One single-mode fiber OLT, long wavelength, 10km"
REFERENCE "[IEEE802.3], Section 59"
::= { dot3MauType 47 }
dot3MauType1000BaseBX10U OBJECT-IDENTITY
STATUS current
DESCRIPTION "One single-mode fiber ONU, long wavelength, 10km"
REFERENCE "[IEEE802.3], Section 59"
::= { dot3MauType 48 }
dot3MauType1000BaseLX10 OBJECT-IDENTITY
STATUS current
DESCRIPTION "Two sigle-mode fiber, long wavelength, 10km"
REFERENCE "[IEEE802.3], Section 59"
::= { dot3MauType 49 }
dot3MauType1000BasePX10D OBJECT-IDENTITY
STATUS current
DESCRIPTION "One single-mode fiber EPON OLT, 10km"
REFERENCE "[IEEE802.3], Section 60"
::= { dot3MauType 50 }
dot3MauType1000BasePX10U OBJECT-IDENTITY
STATUS current
DESCRIPTION "One single-mode fiber EPON ONU, 10km"
REFERENCE "[IEEE802.3], Section 60"
::= { dot3MauType 51 }
Beili Standards Track [Page 61]
RFC 4836 MAU MIB April 2007
dot3MauType1000BasePX20D OBJECT-IDENTITY
STATUS current
DESCRIPTION "One single-mode fiber EPON OLT, 20km"
REFERENCE "[IEEE802.3], Section 60"
::= { dot3MauType 52 }
dot3MauType1000BasePX20U OBJECT-IDENTITY
STATUS current
DESCRIPTION "One single-mode fiber EPON ONU, 20km"
REFERENCE "[IEEE802.3], Section 60"
::= { dot3MauType 53 }
END
6. Security Considerations
The IANA-MAU-MIB does not define any management objects. Instead, it
defines a set of textual conventions which are used by the MAU-MIB
and may be used by other MIB modules to define management objects.
Meaningful security considerations can only be written for MIB
modules that define management objects.
There are a number of management objects defined in the MAU-MIB that
have a MAX-ACCESS clause of read-write. Setting these objects can
have a serious effect on the operation of the network, including:
o enabling or disabling a MAU
o changing a MAU's default type
o enabling, disabling, or restarting autonegotiation
o modifying the capabilities that a MAU advertizes during
autonegotiation.
Such objects may be considered sensitive or vulnerable in some
network environments. The support for SET operations in a non-secure
environment without proper protection can have a negative effect on
network operations.
Some of the readable objects in the MAU-MIB module (i.e., objects
with a MAX-ACCESS other than not-accessible) may be considered
sensitive or vulnerable in some network environments. In some
environments, it may be undesirable to allow unauthorized parties to
access statistics or status information about individual links in a
network. It is thus important to control even GET and/or NOTIFY
access to these objects and possibly to even encrypt the values of
these objects when sending them over the network via SNMP.
Beili Standards Track [Page 62]
RFC 4836 MAU MIB April 2007
SNMP versions prior to SNMPv3 did not include adequate security.
Even if the network itself is secure (for example by using IPsec),
even then, there is no control as to who on the secure network is
allowed to access and GET/SET (read/change/create/delete) the objects
in the MAU-MIB module.
It is RECOMMENDED that the implementors consider the security
features as provided by the SNMPv3 framework (see [RFC3410], section
8), including full support for the SNMPv3 cryptographic mechanisms
(for authentication and privacy).
Furthermore, deployment of SNMP versions prior to SNMPv3 is NOT
RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of the MAU-MIB module is properly configured to give access
to the objects only to those principals (users) that have legitimate
rights to indeed GET or SET (change/create/delete) them.
7. IANA Considerations
This document defines first version of the IANA-maintained IANA-MAU-
MIB module. It is intended that each new MAU type, Media Available
state, Auto Negotiation capability, and/or Jack type defined by the
IEEE 802.3 working group and approved for publication in a revision
of IEEE Std 802.3 will be added to the IANA-maintaned MIB module,
provided that it is suitable for being managed by the base objects in
the MAU-MIB module.
For each new MAU type added, a short description of the MAU
technology and, wherever possible, a reference to a publicly
available specification SHOULD be specified. An Expert Review, as
defined in RFC 2434 [RFC2434], is REQUIRED, for each modification.
8. Acknowledgments
This document was produced by the IETF Ethernet Interfaces and Hub
MIB Working Group, whose efforts were greatly advanced by the
contributions of the following people:
Mike Heard
John Flick
Dan Romascanu
This document is based on the Proposed Standard MAU MIB, RFC 3636
[RFC3636], edited by John Flick of Hewlett-Packard, and produced by
Beili Standards Track [Page 63]
RFC 4836 MAU MIB April 2007
the Ethernet Interfaces and Hub MIB Working Group. It extends that
document by moving the object identities and textual conventions for
MAU types into a IANA-maintained MIB module. In addition, support is
provided for the EFM and 10GBASE-CX4 MAUs as defined in [IEEE802.3ah]
and [IEEE802.3ak] respectively.
RFC 3636, in turn, was based on the Proposed Standard MAU MIB, RFC
2668 [RFC2668], edited by John Flick of Hewlett-Packard and Andrew
Smith, then of Extreme Networks, and produced by the Ethernet
Interfaces and Hub MIB Working Group. It extends that document by
providing support for 10 Gb/s MAUs as defined in [IEEE802.3ae].
RFC 2668, in turn, was based on the Proposed Standard MAU MIB, RFC
2239 [RFC2239], edited by Kathryn de Graaf, then of 3Com, and Dan
Romascanu, then of Madge Networks, and produced by the Ethernet
Interfaces and Hub MIB Working Group. It extended that document by
providing support for 1000 Mb/sec MAUs, PAUSE negotiation and remote
fault status as defined in [IEEE802.3].
RFC 2239, in turn, was based on the Proposed Standard MAU MIB, RFC
1515 [RFC1515], edited by Donna McMaster, then of SynOptics
Communications, Keith McCloghrie, then of Hughes LAN Systems, and Sam
Roberts, then of Farallon Computing, and produced by the Hub MIB
Working Group. It extends that document by providing support for 100
Mb/sec MAUs, full duplex MAUs, auto-negotiation, and jack management
as defined in [IEEE802.3].
9. References
9.1. Normative References
[IEEE802.3] IEEE, "IEEE Standard for Information technology -
Telecommunications and information exchange between
systems - Local and metropolitan area networks -
Specific requirements - Part 3: Carrier sense multiple
access with collision detection (CSMA/CD) access
method and physical layer specifications", IEEE
Std 802.3-2005, December 2005.
[IEEE802.3ae] IEEE, "IEEE Standard for Information technology -
Telecommunications and information exchange between
systems - Local and metropolitan area networks -
Specific requirements - Part 3: Carrier sense multiple
access with collision detection (CSMA/CD) access
method and physical layer specifications - Media
Access Control (MAC) Parameters, Physical Layer and
Management Parameters for 10 Gb/s Operation", IEEE
Std 802.3ae-2002, August 2002.
Beili Standards Track [Page 64]
RFC 4836 MAU MIB April 2007
[IEEE802.3ah] IEEE, "Information technology - Telecommunications and
information exchange between systems - Local and
metropolitan area networks - Specific requirements -
Part 3: Carrier sense multiple access with collision
detection (CSMA/CD) access method and physical layer
specifications - Media Access Control Parameters,
Physical Layers and Management Parameters for
Subscriber Access Networks", IEEE Std 802.3ah-2004,
September 2004.
[IEEE802.3ak] IEEE, "IEEE Standard for Information technology -
Telecommunications and information exchange between
systems - Local and metropolitan area networks -
Specific requirements - Part 3: Carrier sense multiple
access with collision detection (CSMA/CD) access
method and physical layer specifications - Physical
Layer and Management Parameters for 10Gb/s Operation,
Type 10GBASE-CX4", IEEE Std 802.3ak-2004, March 2004.
[RFC2108] de Graaf, K., Romascanu, D., McMaster, D., and K.
McCloghrie, "Definitions of Managed Objects for IEEE
802.3 Repeater Devices using SMIv2", RFC 2108,
February 1997.
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[RFC2434] Narten, T. and H. Alvestrand, "Guidelines for Writing
an IANA Considerations Section in RFCs", BCP 26,
RFC 2434, October 1998.
[RFC2578] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Structure of Management
Information Version 2 (SMIv2)", STD 58, RFC 2578,
April 1999.
[RFC2579] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Textual Conventions for SMIv2",
STD 58, RFC 2579, April 1999.
[RFC2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder,
"Conformance Statements for SMIv2", STD 58, RFC 2580,
April 1999.
[RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces
Group MIB", RFC 2863, June 2000.
Beili Standards Track [Page 65]
RFC 4836 MAU MIB April 2007
[RFC3635] Flick, J., "Definitions of Managed Objects for the
Ethernet-like Interface Types", RFC 3635,
September 2003.
9.2. Informative References
[RFC1515] McMaster, D., McCloghrie, K., and S. Roberts,
"Definitions of Managed Objects for IEEE 802.3 Medium
Attachment Units (MAUs)", RFC 1515, September 1993.
[RFC2239] de Graaf, K., Romascanu, D., McMaster, D., McCloghrie,
K., and S. Roberts, "Definitions of Managed Objects
for IEEE 802.3 Medium Attachment Units (MAUs) using
SMIv2", RFC 2239, November 1997.
[RFC2668] Smith, A., Flick, J., de Graaf, K., Romascanu, D.,
McMaster, D., McCloghrie, K., and S. Roberts,
"Definitions of Managed Objects for IEEE 802.3 Medium
Attachment Units (MAUs)", RFC 2668, August 1999.
[RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart,
"Introduction and Applicability Statements for
Internet-Standard Management Framework", RFC 3410,
December 2002.
[RFC3418] Presuhn, R., "Management Information Base (MIB) for
the Simple Network Management Protocol (SNMP)",
STD 62, RFC 3418, December 2002.
[RFC3636] Flick, J., "Definitions of Managed Objects for IEEE
802.3 Medium Attachment Units (MAUs)", RFC 3636,
September 2003.
[RFC3637] Heard, C., "Definitions of Managed Objects for the
Ethernet WAN Interface Sublayer", RFC 3637,
September 2003.
Author's Address
Edward Beili
Actelis Networks
Bazel 25
Petach-Tikva
Israel
Phone: +972-3-924-3491
EMail: edward.beili@actelis.com
Beili Standards Track [Page 66]
RFC 4836 MAU MIB April 2007
Full Copyright Statement
Copyright (C) The IETF Trust (2007).
This document is subject to the rights, licenses and restrictions
contained in BCP 78, and except as set forth therein, the authors
retain all their rights.
This document and the information contained herein are provided on an
"AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY, THE IETF TRUST AND
THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF
THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Intellectual Property
The IETF takes no position regarding the validity or scope of any
Intellectual Property Rights or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; nor does it represent that it has
made any independent effort to identify any such rights. Information
on the procedures with respect to rights in RFC documents can be
found in BCP 78 and BCP 79.
Copies of IPR disclosures made to the IETF Secretariat and any
assurances of licenses to be made available, or the result of an
attempt made to obtain a general license or permission for the use of
such proprietary rights by implementers or users of this
specification can be obtained from the IETF on-line IPR repository at
http://www.ietf.org/ipr.
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights that may cover technology that may be required to implement
this standard. Please address the information to the IETF at
ietf-ipr@ietf.org.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.
Beili Standards Track [Page 67]