ARMWARE RFC Archive <- RFC Index (1..100)

RFC 54

Updated by RFC 57

Network Working Group                               Steve Crocker (UCLA)
Request for Comments # 54                              Jon Postel (UCLA)
June 18, 1970                                     John Newkirk (Harvard)
                                                   Mike Kraley (Harvard)

                    An Official Protocol Proffering

I. INTRODUCTION

   As advertised in NEW/RFC #53, we are submitting the protocol herein
   for criticism, comments, etc.  We intend for this protocol to become
   the initial official protocol, and will, therefore, be happiest if no
   serious objections are raised.  Nevertheless, we will entertain all
   manner of criticism until July 13, 1970, and such criticism should be
   published as a NWG/RFC or directed to the first author.

   After July 13, a decision will be made whether to adopt this protocol
   (or slight variation) or whether to redesign it and resubmit it for
   criticism.

Only the Protocol

   In preceding discussions of protocol, no clear distinction has been
   made between the network-wide specifications and local strategies.
   We state here that the only network-wide issues are message formats
   and restrictions on message content.  Implementation of a Network
   Control Program (NCP) and choice of system calls are strictly local
   issues.

   This document is constrained to cover only network-wide issues and
   thus will not treat system calls or NCP tables; nevertheless, a
   protocol is useless without an NCP and a set of system calls, so we
   have expended a great deal of effort in deriving a protypical NCP.
   This effort is reported in NWG/RFC #55, and the reader should
   correlate the protocol presented here with the suggestions for using
   it presented there.  It is important to remember, however, that the
   content of NWG/RFC #55 is only suggestive and that competitive
   proposals should be examined before choosing an implementation.

Flow Control

   In the course of designing this current protocol, we have come to
   understand that flow control is more complex than we imagined.  We
   now believe that flow control techniques will be one of the active
   areas of concern as the network traffic increases.  We have,
   therefore, benefitted from some ideas stimulated by Richard Kaline
   and Anatol Holt and have modified the flow control procedure.
   (Defects in our scheme are, of course, only our fault).  This new

Crocker, Postel, Newkirk & Kraley                              [Page 1]



RFC 54              An Official Protocol Proffering        18 June 1970

   procedure has demonstrable limitations, but has the advantages that
   it is more cleanly implementable and will support initial network
   use.  This is the only substantive change from the protocol already
   agreed upon.

   The new flow control mechanism requires the receiving host to
   allocate buffer space for each connection and to notify the sending
   host of how much space in bits is available.  The sending host keeps
   track of how much room is available and never sends more text than it
   believes the receiving host can accept.

   To implement this mechanism, the sending host keeps a counter
   associated with each connection.  The counter is initialized to zero,
   increased by control commands sent from the receiving host, and
   decremented by the text length of any message sent over the
   connection.  The sending host is prohibited from sending text longer
   than the value of the counter, so the counter never goes below zero.

   Ideally, the receiving host will allocate some buffer space as soon
   as the connection is established.  The amount allocated must never
   exceed what the receiver can guarantee to accept.  As text arrives,
   it occupies the allocated buffer space.  When the receiving process
   absorbs the waiting text from the buffer, the NCP fires back a new
   allocation of space for that connection.  The NCP may allocate space
   even if the receiving process has not absorbed waiting text if it
   believes that extra buffer space is appropriate.  Similarly, the NCP
   may decide not to reallocate buffer space after the receiving process
   makes it available.

   The control command which allocates space is

                   ALL     <link>  <space>

   This command is sent only from the receiving host to the sending
   host.

   This formulation of flow control obviates the RSM and SPD commands in
   NWG/RFC #36, and the Host-to-Imp message type 10 and Imp-to-Host
   message types 10 and 11 in the current revision of BBN Report 1822.

   The obvious limitation in this scheme is that the receiving host is
   not permitted to depend upon average buffer usage -- worse case is
   always assumed.  If only a few connections are open, it is unlikely
   that there would be much savings.  However, for more than a few
   connections, average buffer usage will be much less than allocated
   buffer space.  We have looked at extensions of this protocol which
   would include adaptive allocation, and we believe this to be
   feasible.  For the present this limited scheme seems best, and we

Crocker, Postel, Newkirk & Kraley                              [Page 2]



RFC 54              An Official Protocol Proffering        18 June 1970

   look forward to discussing more sophisticated schemes later.  The old
   scheme of special RFNM's, etc. also remains under discussion.

   In order to answer questions and discuss details, we will hold a pair
   of network meetings.  The first will be on June 29 at Harvard and the
   second on July 1 at UCLA.  We request that no more than on programmer
   per host attend a meeting and that hosts be represented at only one
   of these meetings.  Two of us (J.N. and S.C.) will be at both
   meetings.

   To make reservations to attend the Harvard meeting, contact

   Mrs. Margi Robison
   (617) 495-3989
      or 495-3991

   To make reservations to attend the UCLA meeting, contact Mrs. Benita
   Kirstel (213) 825-2368.

II. THE PROTOCOL

   The notion of a connection as explained in NWG/RFC #33 pervades the
   protocol.  A connection is a simplex communication path, intended to
   be between two processes.

   The primary function of the protocol is to provide for
       (1)  establishment of connections,
       (2)  regulation of flow over connections, and
       (3)  termination of connections.

   In addition, the protocol provides some ancillary functions such as
   sending simulated interrupt pulses and echoing test messages.

   To provide a path for exchanging information about connections, we
   designate specific links, i.e. link one between each pair of hosts to
   be control links.  Traffic on control links consists only of control
   commands, defined below.

   Connections are named by a pair of sockets.  Sockets are 40 bit names
   which are known throughout the network.  Each host is assigned a
   private subset of these names, and a command which requests a
   connection names one socket which is local to the requesting host and
   one local to the receiver of the request.

   Sockets are polarized; even numbered sockets are receive sockets; odd
   numbered ones are send sockets.  One of each is required to make a
   connection.

Crocker, Postel, Newkirk & Kraley                              [Page 3]



RFC 54              An Official Protocol Proffering        18 June 1970

   To facilitate transmission of information over a connection, a unique
   link is assigned to each connection.  One of the steps in
   establishing a connection, therefore, is the assignment of a link.
   Of the non-control links, zero is reserved for intra-network use, and
   links 32 to 255 are reserved for experiment and expansion.  Thus only
   links 2 through 31 are available for regular use.  Link assignment
   must either always be done by the receiver or always by the sender.
   We have (almost) arbitrarily chosen this to be the receiver's
   responsibility.

   All regular messages consist of a 32 bit leader, marking, text, and
   padding.  Marking is a (possibly null) sequence of zeroes followed by
   a 1; padding is a 1 followed by a (possibly null) sequence of zeroes.

   A regular message sent over the control link (link 1) is called a
   control message.  Its text is an integral (possibly zero) number of
   control commands in the form described below, and this text must end
   on a command boundary.

   The commands used to establish a connection are STR and RTS.  The STR
   command is sent from a prospective sender to a prospective receiver.
   Its <my socket> field contains a send socket local to the prospective
   sender; its <your socket> field contains a receive socket local to
   the prospective receiver.  The RTS command is the dual, but is also
   contains a <link> field for link assignment.  These two commands are
   referred to as requests-for-connection (RFC).  A STR and an RTS match
   if the <my socket> field of one is identical to the <your socket>
   field of the other and vice versa.  A connection is established where
   a matching pair of RFC's have been exchanged.

   Hosts are prohibited from establishing more than one connection to
   any local socket.  Therefore, a host may not use a socket for the <my
   socket>  field of an RFC if that socket is mentioned in a previous
   RFC and the connection is not yet terminated.

   The command used to terminate a connection is CLS.  Each side must
   send and receive a CLS command before a connection is completely
   terminated and the sockets are free to participate in other
   connections.  It is not necessary that both RFC's be exchanged before
   a connection is terminated.  More details on termination are given
   below.

   After a connection is established, the receiving host sends a ALL
   command which allocates space for the connection.  The sender keeps
   track of how much space is available in the receiving host and does
   not transmit more text than the receiving host can accept, as
   explained above.  A sender is also constrained by the local IMP from
   sending a message over a connection until  the RFNM from the previous

Crocker, Postel, Newkirk & Kraley                              [Page 4]



RFC 54              An Official Protocol Proffering        18 June 1970

   message is received.

   After a connection is established, CLS commands sent by the receiver
   and sender have slightly different effects.  CLS command sent by the
   sender indicate that no more messages will be sent over the
   connection.  This command must not be sent if there is a message in
   transit over the connection.

   CLS commands sent by the receiver act as demands on the sender to
   terminate transmission.  However, since there is a delay in getting
   the CLS command to the sender, the receiver must expect its buffers
   to fill to the limit provided in ALL commands.

   While a connection is established, either side may send INR or INS
   commands.  The interpretation of these commands is a local matter,
   but in general they will provide and escape function.

   Note that the ALL, INR and INS commands may be sent only after the
   connection is established and before a CLS command is sent.

   A very simple test facility is provided by the ECO and ERP commands.
   Upon receiving a ECO command, a host must change the first eight bits
   to ERP and return it.  These commands have no relationship to
   connections.

   A NOP command is included for convenience.  It is coded as zero to
   facilitate command message construction.

   Finally, an ERR command is included for notifying a foreign host it
   has (apparently) made an error.  At present, no specific list of
   errors is defined, and no action is defined for the receipt of ERR
   commands.  Hosts should log ERR commands upon receipt so that system
   programmers can diagnose the trouble.  A host may generate an ERR
   command at any time and for any reason, but it is advised that each
   host publish an exhaustive list of the ERR commands it may sent and
   their interpretations.

NETWORK CONTROL COMMANDS

   The following is a detailed description of the structure and format
   of each of the control commands.

   To facilitate and clarify socket descriptions, the following
   conventions have been adopted:

   <my socket> and <your socket> are used in the command descriptions.

Crocker, Postel, Newkirk & Kraley                              [Page 5]



RFC 54              An Official Protocol Proffering        18 June 1970

   <my socket> is local to the originator of the command.

   <your socket> is local to the receiver of the command.

CONTROL COMMAND FORMATS

   No Operation
                      _______
                     |       |
                     |  NOP  |
                     |_______|

   Request Connection, Receiver to Sender
                      ______________________________________________
                     |       |             |               |        |
                     |  RTS  |  my socket  |  your socket  |  link  |
                     |_______|_____________|_______________|________|

   Request Connection, Sender to Receiver
                      _____________________________________
                     |       |             |               |
                     |  STR  |  my socket  |  your socket  |
                     |_______|_____________|_______________|

   Close
                      _____________________________________
                     |       |             |               |
                     |  CLS  |  my socket  |  your socket  |
                     |_______|_____________|_______________|

   Allocate
                      __________________________
                     |       |        |         |
                     |  ALL  |  link  |  space  |
                     |_______|________|_________|

   Interrupt Sent by Receiving Process
                      _______________
                     |      |        |
                     | INR  |  link  |
                     |______|________|

Crocker, Postel, Newkirk & Kraley                              [Page 6]



RFC 54              An Official Protocol Proffering        18 June 1970

   Interrupt Sent by Sending Process
                     _______________
                    |      |        |
                    | INS  |  link  |
                    |______|________|

   Echo Request
                     ____________________________   _________
                    |       |                    \  \        |
                    |  ECO  |  length            /  /  text  |
                    |_______|____________________\  \________|

   Echo Reply
                     ____________________________   _________
                    |       |                    \  \        |
                    |  ERP  |  length            /  /  text  |
                    |_______|____________________\  \________|

   Error Detected
                     ____________________________   _________
                    |       |                    \  \        |
                    |  ERR  |  length            /  /  text  |
                    |_______|____________________\  \________|

   The host is specified in the leader.

   <link> is 8 bits

   <space> is 32 bits long and is an unsigned integer.

   <length> is an unsigned 16 bit integer.

   <text> is as long as the length.  The command is therefore 24 bits
   longer that the length.  Maximum length is one message, to facilitate
   command decoding and manipulation.

   All control command codes are 8 bit long:

             NOP = 0
             RTS = 1
             STR = 2
             CLS = 3
             ALL = 4
             INR = 5

Crocker, Postel, Newkirk & Kraley                              [Page 7]



RFC 54              An Official Protocol Proffering        18 June 1970

             INS = 6
             ECO = 7
             ERP = 8
             ERR = 9

   <my socket> and <your socket> are 32 bits long,
                     _______________________
                    |               |       |
                    |  User number  |  AEN  |
                    |_______________|_______|

   24 bits for user number and 8 bits for AEN.

III.  Conclusion

   Extensions to the Protocol

   Some issues have not been adequately treated in the current protocol.
   We have in mind the following topics to consider more thoroughly and
   perhaps experiment with.

   1. More Sophisticated Flow Control.

   As mentioned above, other schemes for flow control are still being
   considered.  Other than the necessity of providing some form of it,
   we are completely unsure of the nature of the problem.  It may turn
   out that the present scheme is completely adequate; it may also turn
   out that we will need a much more complex scheme.

   2. Error Detection and Recovery

   As we gain some experience with the network, we will develop a better
   understanding of what errors can occur and, perhaps more importantly,
   what to do about these errors.  We expect the protocol to change as
   we understand error control.

   3. Start Up and Shut Down Procedures

   We have not done enough thinking about the problem of the host which
   participates part-time in the network, which ceases normal network
   operation but remains on the network for special purposes, or which
   recovers from a system failure.  These issues are critical to robust
   network operation and are possibly our highest priority.  4. Query
   and Response

   A host-to-host status test would be a valuable tool, but it is not
   yet clear what is appropriate to provide.

Crocker, Postel, Newkirk & Kraley                              [Page 8]



RFC 54              An Official Protocol Proffering        18 June 1970

Coming onto the Network

   We suggest that hosts come onto the network gingerly.  First, each
   host should thoroughly exercise connections to itself.  Then it
   should arrange experiments with some other host who is already
   functioning.  Finally, it may begin to exercise the facilities of
   other hosts.  It is not clear at this time which host will be in the
   best position to help other hosts first, but UCLA will attempt to
   serve this function.

Private Networking

   A common ploy is to use the IMP to connect several local computers,
   one or more of which is not available to the whole network.  For
   example, Harvard is connecting its PDP-1 to its PDP-10 via an IMP;
   Lincoln Laboratories is connecting its TSP to the 360/67 and the TX2
   via an IMP; and UCLA is similarly connecting a XDS 920 to its Sigma-
   7.  In each of these cases, the small machine will not initially
   provide services to the network.

   Although there should be no unwanted traffic to any of these extra
   hosts, it is desirable that they conform minimally to the network
   protocol.  Provided that they never initiate a connection or send out
   spurious control commands, it is sufficient for a host to respond to
   CLS commands with acknowledging CLS commands, and to respond to ECO
   commands with ERP commands.

Acknowledgments

   The work presented above is only a small portion of the concurrent
   effort.  Most of the related effort will be reported in immediately
   forthcoming RFC's.  A number of people provided extremely valuable
   aid during the last two weeks.  We are particularly grateful to
   Professor George Mealy of Harvard for supporting four of his students
   to come westward to work on the network, to Robert Uzgalis for
   facilitating access to CCN at UCLA, and to the secretarial staff of
   the Computer Science Division of the University of Utah, and
   especially Peggy Tueller and Marcella Sanchez, for excellent help in
   preparing these documents.

       [ This RFC was put into machine readable form for entry ]
      [ into the online RFC archives by Eitetsu Baumgardner 3/97 ]

Crocker, Postel, Newkirk & Kraley                              [Page 9]