<- RFC Index (6701..6800)
RFC 6767
Internet Engineering Task Force (IETF) E. Beili
Request for Comments: 6767 Actelis Networks
Category: Standards Track M. Morgenstern
ISSN: 2070-1721 ECI Telecom
February 2013
Ethernet-Based xDSL Multi-Pair Bonding (G.Bond/Ethernet) MIB
Abstract
This document defines a Management Information Base (MIB) module for
use with network management protocols in TCP/IP-based internets.
This document defines an extension to the GBOND-MIB module with a set
of objects for managing Ethernet-based multi-pair bonded Digital
Subscriber Line (xDSL) interfaces, as defined in ITU-T Recommendation
G.998.2.
Status of This Memo
This is an Internet Standards Track document.
This document is a product of the Internet Engineering Task Force
(IETF). It represents the consensus of the IETF community. It has
received public review and has been approved for publication by the
Internet Engineering Steering Group (IESG). Further information on
Internet Standards is available in Section 2 of RFC 5741.
Information about the current status of this document, any errata,
and how to provide feedback on it may be obtained at
http://www.rfc-editor.org/info/rfc6767.
Copyright Notice
Copyright (c) 2013 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Beili & Morgenstern Standards Track [Page 1]
RFC 6767 G.Bond/Ethernet MIB February 2013
Table of Contents
1. Introduction ....................................................2
2. The Internet-Standard Management Framework ......................2
3. The Broadband Forum Management Framework for xDSL Bonding .......3
4. Relationship to Other MIB Modules ...............................3
4.1. Relationship to Interfaces Group MIB Module ................3
4.2. Relationship to G.Bond MIB Module ..........................3
4.2.1. BACP-Based Discovery ................................3
4.3. Relationship to EFM Copper MIB Module ......................5
4.4. Relationship to IEEE 802.3.1 MIB Modules ...................6
5. MIB Structure ...................................................6
5.1. Overview ...................................................6
5.2. Performance Monitoring .....................................7
5.3. Mapping of Broadband Forum TR-159 Managed Objects ..........7
6. G.Bond/Ethernet MIB Definitions .................................9
7. Security Considerations ........................................49
8. IANA Considerations ............................................50
9. Acknowledgments ................................................50
10. References ....................................................50
10.1. Normative References .....................................50
10.2. Informative References ...................................52
1. Introduction
Ethernet-based xDSL Multi-Pair Bonding, a.k.a. G.Bond/Ethernet, is
specified in ITU-T Recommendation G.998.2 [G.998.2], which defines a
method for bonding (or aggregating) multiple xDSL lines (or
individual bearer channels in multiple xDSL lines) into a single
bidirectional logical link carrying Ethernet traffic.
The MIB module defined in this document provides G.Bond/
Ethernet-specific objects for the management of G.998.2 bonded
interfaces, extending the common bonding objects specified in the
GBOND-MIB module [RFC6765].
2. The Internet-Standard Management Framework
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to section 7 of
RFC 3410 [RFC3410].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. MIB objects are generally
accessed through the Simple Network Management Protocol (SNMP).
Objects in the MIB are defined using the mechanisms defined in the
Structure of Management Information (SMI). This memo specifies a MIB
Beili & Morgenstern Standards Track [Page 2]
RFC 6767 G.Bond/Ethernet MIB February 2013
module that is compliant to the SMIv2, which is described in STD 58,
RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
[RFC2580].
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
"OPTIONAL" in this document are to be interpreted as described in
BCP 14, RFC 2119 [RFC2119].
3. The Broadband Forum Management Framework for xDSL Bonding
This document makes use of the Broadband Forum technical report
"Management Framework for xDSL Bonding" [TR-159], defining a
management model and a hierarchy of management objects for the bonded
xDSL interfaces.
4. Relationship to Other MIB Modules
This section outlines the relationship of the MIB modules defined in
this document with other MIB modules described in the relevant RFCs.
Specifically, the following MIB modules are discussed: the Interfaces
Group MIB (IF-MIB), G.Bond MIB (GBOND-MIB), and Ethernet in the First
Mile (EFM) Copper MIB (EFM-CU-MIB).
4.1. Relationship to Interfaces Group MIB Module
A G.Bond/Ethernet port is a private case of a bonded multi-pair xDSL
interface and as such is managed using generic interface management
objects defined in the IF-MIB [RFC2863]. In particular, an interface
index (ifIndex) is used to index instances of G.Bond/Ethernet ports,
as well as xDSL lines/channels, in a managed system.
4.2. Relationship to G.Bond MIB Module
The GBOND-MIB module [RFC6765] defines management objects common for
all bonded multi-pair xDSL interfaces. In particular, it describes
the bonding management, bonded port and channel configuration,
handshake-based discovery, initialization sequence, etc.
Both the GBOND-MIB [RFC6765] and G9982-MIB (this document) modules
are REQUIRED to manage a G.Bond/Ethernet port.
4.2.1. BACP-Based Discovery
All G.998 protocols share a remote Bonding Channel Entity (BCE)
discovery, using the [G.994.1] handshake (G.hs). The GBOND-MIB
module provides an example of an automatic BCE connection to the
corresponding Generic Bonding Sub-layer (GBS) ports of a generic
Beili & Morgenstern Standards Track [Page 3]
RFC 6767 G.Bond/Ethernet MIB February 2013
G.998 multi-port Central Office (CO) device, using G.hs-based BCE
discovery. Amendment 2 to the ITU-T G.998.2 specification
[G.998.2-Amd2] provides an alternative optional Bonding Aggregation
Control Protocol (BACP) for in-service discovery, aggregation, and
pair management.
The following pseudocode gives the same example of the discovery and
automatic BCE assignment for a multi-GBS G.Bond/Eth CO device, using
BACP objects defined in this MIB module, as well as the
IF-CAP-STACK-MIB [RFC5066] and IF-MIB modules. Note that automatic
BCE assignment is only shown here for the purposes of the example.
Fixed BCE pre-assignment, manual assignment, or auto-assignment using
an alternative internal algorithm may be chosen by a particular
implementation:
// Go over all GBS ports in the CO device
FOREACH gbs[i] IN CO_device
{ // Perform discovery and auto-assignment on GBS ports
// with room for more channels.
IF ( gbs[i].NumBCEs < gbs[i].BondCapacity )
{ IF ( gbs[i].g9982OperCp == cpBACP )
{ // Using BACP
// Get Eligible Group ID and Remote Group ID
// from a connected BCE (during BACP
// initialization, each BCE is connected to its own GBS)
gid = ifStackTable[gbs[i]].bce[0].g9982BceEligibleGroupID;
rgid =
ifStackTable[gbs[i]].bce[0].g9982BcePeerEligibleGroupID;
// Go over all disconnected channels, which can
// potentially be connected to the GBS
FOREACH bce[j] IN ifCapStackTable[gbs[i]] AND
NOT IN ifStackTable[gbs[i]] // not connected
{ // Read the Remote Group ID for the selected BCE
// and compare it with the Remote Group ID of the connected
// BCE.
r = bce[j].g9982BcePeerEligibleGroupID;
IF ( r == rgid AND gbs[i].NumBCEs < gbs[i].BondCapacity )
{ // The Remote Terminal device (RT) connected via BCE[j] is
// a peer for GBS[i], and there is room for another BCE in
// the GBS[i] aggregation group (max. Bonding capacity is
// not reached yet).
// Connect this BCE to the GBS (via the ifStackTable; the
// ifInvStackTable, which is the inverse of the
// ifStackTable, is updated automatically; i.e., gbs[i] is
// auto-added to ifInvStackTable[bce[j]]).
Beili & Morgenstern Standards Track [Page 4]
RFC 6767 G.Bond/Ethernet MIB February 2013
ADD bce[j] TO ifStackTable[gbs[i]];
gbs[i].NumBCEs = gbs[i].NumBCEs + 1;
}
}
// At this point, we have discovered all local BCEs that
// are physically connected to the same RT
// and have connected them to GBS[i]. Go to the next GBS.
BREAK;
}
ELSE
{ // Use default G.hs discovery protocol.
...
}
}
}
An SNMP agent for a G.Bond device builds the ifCapStackTable and its
inverse -- the ifInvCapStackTable -- on device initialization,
according to the cross-connect capabilities of the device. When BACP
is used, the g9982BceConfEligibleGroupID object identifying bonding
eligibility MUST be automatically updated whenever the
ifCapStackTable/ifInvCapStackTable are changed.
4.3. Relationship to EFM Copper MIB Module
The EFM-CU-MIB module [RFC5066] defines objects for managing Ethernet
in the First Mile Copper (EFMCu) interfaces 10PASS-TS and 2BASE-TL,
as defined in IEEE Std 802.3-2005 [802.3]. These interfaces are
based on Single-pair High-speed DSL (SHDSL) [G.991.2] and Very high
speed DSL (VDSL) [G.993.1] technology, respectively, and can be
optionally aggregated (bonded).
The ITU-T G.998.2 specification extends the IEEE 802.3 Clause 61
bonding to work over any xDSL technology, providing the ability to
bond individual channels as well as physical lines. It also allows
the use of alternative High-level Data Link Control (HDLC)
encapsulation instead of the default 64/65-octet encapsulation and
adds a new optional Bonding Aggregation Control Protocol (BACP) for
in-service discovery, aggregation, and pair management instead of the
default G.hs-based bonding protocol, which cannot be used in-service,
while the link is 'up'.
EFM-CU-MIB can be used to manage all aspects of the EFMCu physical
interfaces (PHYs), including complete (within the scope of the 802.3
standard) management of the SHDSL/VDSL lines. The GBOND-MIB and
G9982-MIB modules, on the other hand, provide management objects only
for the bonding part, leaving the management of the individual xDSL
interfaces (lines/channels) to the respective xDSL-LINE-MIB modules.
Beili & Morgenstern Standards Track [Page 5]
RFC 6767 G.Bond/Ethernet MIB February 2013
Therefore, an IEEE 802.3 2BASE-TL/10PASS-TS interface can be managed
by either combination of the following MIB modules:
IF-MIB + IF-CAP-STACK-MIB + EtherLike-MIB + MAU-MIB + EFM-CU-MIB
IF-MIB + IF-CAP-STACK-MIB + GBOND-MIB + G9982-MIB +
HDSL2-SHDSL-LINE-MIB/VDSL-LINE-MIB
(The EtherLike-MIB, HDSL2-SHDSL-LINE-MIB, and VDSL-LINE-MIB modules
are found in [RFC3635], [RFC4319], and [RFC3728], respectively.)
Note also that while EFM-CU-MIB relies on the ifMauMediaAvailable
object from MAU-MIB [RFC4836] for the additional bonded xDSL-specific
operational states, GBOND-MIB provides these indications via the
gBondPortStatFltStatus object, complementing the ifOperStatus object
from the IF-MIB.
Finally, the EFM-CU-MIB does not include historical Performance
Monitoring (PM), while the GBOND-MIB/G9982-MIB/xDSL-LINE-MIB
combination provides full PM functionality for a bonded link and
individual xDSL lines.
4.4. Relationship to IEEE 802.3.1 MIB Modules
The IEEE 802.3 working group chartered a task force [IEEE802.3.1],
which continues the development of standard Ethernet-related MIB
modules based on the initial work done in the IETF. Future projects
resulting from the work of this task force may include and possibly
extend the work done in the IETF.
5. MIB Structure
5.1. Overview
The main management objects defined in the G9982-MIB module are split
into 2 groups, structured as recommended by RFC 4181 [RFC4181]:
o g9982Port - containing objects for configuration, capabilities,
status, and PM of G.Bond/Eth ports. Note that the rest of the
objects for the Generic Bonding Sub-layer (GBS) port
configuration, capabilities, status, notifications, and PM are
located in the GBOND-MIB module.
o g9982Bce - containing objects representing OPTIONAL status
information and BACP configuration for each Bonding Channel Entity
(BCE). Note that the rest of the objects for the BCE
Beili & Morgenstern Standards Track [Page 6]
RFC 6767 G.Bond/Ethernet MIB February 2013
configuration, capabilities, status, and notifications are located
in relevant xDSL line MIB modules as well as in the GBOND-MIB
module.
5.2. Performance Monitoring
The OPTIONAL Performance Monitoring counters, thresholds, and history
buckets (interval-counters), similar to those defined in [TR-159],
are implemented using the textual conventions defined in the
HC-PerfHist-TC-MIB [RFC3705]. The HC-PerfHist-TC-MIB defines 64-bit
versions of the textual conventions found in PerfHist-TC-MIB
[RFC3593].
The agent SHOULD align the beginning of each interval to a fifteen-
minute boundary of a wall clock. Likewise, the beginning of each
one-day interval SHOULD be aligned with the start of a day.
Counters are not reset when a GBS is re-initialized, but rather only
when the agent is reset or re-initialized.
5.3. Mapping of Broadband Forum TR-159 Managed Objects
This section contains the mapping between relevant managed objects
(attributes) defined in [TR-159] and the managed objects defined in
this document.
+---------------------------------+---------------------------------+
| TR-159 Managed Object | Corresponding SNMP Object |
+---------------------------------+---------------------------------+
| oBondEth - Basic Package | |
| (Mandatory) | |
+---------------------------------+---------------------------------+
| aEthBACPSupported | g9982PortCapBacpSupported |
+---------------------------------+---------------------------------+
| aEthTcAdminType | g9982PortConfTcAdminType |
+---------------------------------+---------------------------------+
| aEthTcOperType | g9982PortStatTcOperType |
+---------------------------------+---------------------------------+
| aEthTcTypesSupported | g9982PortCapTcTypesSupported |
+---------------------------------+---------------------------------+
| aEthRxErrors | g9982PortStatRxErrors |
+---------------------------------+---------------------------------+
| aEthRxSmallFragments | g9982PortStatRxSmallFragments |
+---------------------------------+---------------------------------+
| aEthRxLargeFragments | g9982PortStatRxLargeFragments |
+---------------------------------+---------------------------------+
| aEthRxBadFragments | g9982PortStatRxBadFragments |
+---------------------------------+---------------------------------+
Beili & Morgenstern Standards Track [Page 7]
RFC 6767 G.Bond/Ethernet MIB February 2013
+---------------------------------+---------------------------------+
| aEthRxLostFragments | g9982PortStatRxLostFragments |
+---------------------------------+---------------------------------+
| aEthRxLostStarts | g9982PortStatRxLostStarts |
+---------------------------------+---------------------------------+
| aEthRxLostEnds | g9982PortStatRxLostEnds |
+---------------------------------+---------------------------------+
| aEthRxOverflows | g9982PortStatRxOverflows |
+---------------------------------+---------------------------------+
| oBondEth - BACP Package | |
| (Optional) | |
+---------------------------------+---------------------------------+
| aEthAdminCP | g9982PortConfAdminCp |
+---------------------------------+---------------------------------+
| aEthOperCP | g9982PortStatOperCp |
+---------------------------------+---------------------------------+
| oChannel - BACP Package | |
| (Optional) | |
| aChannelEligibleGroupID | g9982BceConfEligibleGroupID |
+---------------------------------+---------------------------------+
| aChannelEligibleStreamID | g9982BceConfPeerEligibleGroupID |
+---------------------------------+---------------------------------+
| oChannel - PM Package | |
| (Optional) | |
+---------------------------------+---------------------------------+
| aChannelPtmTcRxCodingViolations | g9982BceStatTcInCodingErrors |
+---------------------------------+---------------------------------+
| aChannelPtmTcRxCrcErrors | g9982BceStatTcInCrcErrors |
+---------------------------------+---------------------------------+
Table 1: Mapping of TR-159 Managed Objects
Note that some of the mapping between the objects defined in TR-159
and the ones defined in this MIB module is not one-to-one; for
example, while TR-159 PM attributes aGroupPerf* map to the
corresponding gBondPortPm* objects of the GBOND-MIB module, there are
no dedicated PM attributes for the g9982PortPm* objects introduced in
this MIB module. However, since their definition is identical to the
definition of gBondPortPm* objects of the GBOND-MIB module, we can
map g9982PortPm* to the relevant aGroupPerf* attributes of TR-159 and
use the term 'partial mapping' to denote the fact that this mapping
is not one-to-one.
Beili & Morgenstern Standards Track [Page 8]
RFC 6767 G.Bond/Ethernet MIB February 2013
6. G.Bond/Ethernet MIB Definitions
The G9982-MIB module IMPORTS objects from SNMPv2-SMI [RFC2578],
SNMPv2-TC [RFC2579], SNMPv2-CONF [RFC2580], IF-MIB [RFC2863], and
HC-PerfHist-TC-MIB [RFC3705]. The module has been structured as
recommended by [RFC4181].
G9982-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Counter32,
mib-2,
Unsigned32
FROM SNMPv2-SMI -- RFC 2578
TEXTUAL-CONVENTION,
TruthValue,
PhysAddress
FROM SNMPv2-TC -- RFC 2579
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF -- RFC 2580
ifIndex
FROM IF-MIB -- RFC 2863
HCPerfCurrentCount,
HCPerfValidIntervals,
HCPerfInvalidIntervals,
HCPerfTimeElapsed
FROM HC-PerfHist-TC-MIB -- RFC 3705
;
------------------------------------------------------------------------
g9982MIB MODULE-IDENTITY
LAST-UPDATED "201302200000Z" -- 20 February 2013
ORGANIZATION "IETF ADSL MIB Working Group"
CONTACT-INFO
"WG charter:
http://datatracker.ietf.org/wg/adslmib/charter/
Mailing Lists:
General Discussion: adslmib@ietf.org
To Subscribe: adslmib-request@ietf.org
In Body: subscribe your_email_address
Beili & Morgenstern Standards Track [Page 9]
RFC 6767 G.Bond/Ethernet MIB February 2013
Chair: Menachem Dodge
Postal: ECI Telecom, Ltd.
30 Hasivim St.
Petach-Tikva 4951169
Israel
Phone: +972-3-926-8421
EMail: menachemdodge1@gmail.com
Editor: Edward Beili
Postal: Actelis Networks, Inc.
25 Bazel St., P.O.B. 10173
Petach-Tikva 49103
Israel
Phone: +972-3-924-3491
EMail: edward.beili@actelis.com
Editor: Moti Morgenstern
Postal: ECI Telecom
30 Hasivim St.
Petach-Tikva 4951169
Israel
Phone: +972-3-926-6258
EMail: moti.morgenstern@ecitele.com"
DESCRIPTION
"The objects in this MIB module are used to manage the
Ethernet-based multi-pair bonded xDSL interfaces, as defined in
ITU-T Recommendation G.998.2 (G.Bond/Ethernet).
This MIB module MUST be used in conjunction with the GBOND-MIB
module, common to all G.Bond technologies.
The following references are used throughout this MIB module:
[G.998.2] refers to:
ITU-T Recommendation G.998.2: 'Ethernet-based multi-pair
bonding', January 2005.
[G.998.2-Amd2] refers to:
ITU-T Recommendation G.998.2 Amendment 2, December 2007.
[802.3] refers to:
IEEE Std 802.3-2005: 'IEEE Standard for Information
technology - Telecommunications and information exchange
between systems - Local and metropolitan area networks -
Specific requirements -
Beili & Morgenstern Standards Track [Page 10]
RFC 6767 G.Bond/Ethernet MIB February 2013
Part 3: Carrier Sense Multiple Access with Collision
Detection (CSMA/CD) Access Method and Physical Layer
Specifications', December 2005.
[TR-159] refers to:
Broadband Forum Technical Report: 'Management Framework for
xDSL Bonding', December 2008.
Naming Conventions:
BACP - Bonding Aggregation Control Protocol
BCE - Bonding Channel Entity
BTU - Bonding Terminating Unit
BTU-C - Bonding Terminating Unit, CO side
BTU-R - Bonding Terminating Unit, Remote Terminal (CPE) side
CO - Central Office
CPE - Customer Premises Equipment
GBS - Generic Bonding Sub-layer
HDLC - High-level Data Link Control
PTM-TC - Packet Transfer Mode Transmission Convergence
(sub-layer)
SNR - Signal to Noise Ratio
TC - Transmission Convergence (sub-layer)
UAS - Unavailable Seconds
Copyright (c) 2013 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or without
modification, is permitted pursuant to, and subject to the license
terms contained in, the Simplified BSD License set forth in Section
4.c of the IETF Trust's Legal Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info)."
REVISION "201302200000Z" -- 20 February 2013
DESCRIPTION "Initial version, published as RFC 6767."
::= { mib-2 264 }
-- Sections of the module
-- Structured as recommended by RFC 4181, Appendix D
g9982Objects OBJECT IDENTIFIER ::= { g9982MIB 1 }
g9982Conformance OBJECT IDENTIFIER ::= { g9982MIB 2 }
Beili & Morgenstern Standards Track [Page 11]
RFC 6767 G.Bond/Ethernet MIB February 2013
-- Groups in the module
g9982Port OBJECT IDENTIFIER ::= { g9982Objects 1 }
g9982Bce OBJECT IDENTIFIER ::= { g9982Objects 2 }
-------------------------------
-- Textual Conventions
-------------------------------
G9982PtmTcType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention represents possible PTM-TC types in
G.Bond/Eth ports. The following values are defined:
tc6465 - 64/65-octet encapsulation, as defined in
[802.3] Clause 61.3.3.
tcHDLC - HDLC encapsulation, as defined in [G.998.2]
Annex B."
SYNTAX INTEGER {
tc6465(1),
tcHDLC(2)
}
G9982CpType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention represents possible control protocol
types in G.Bond/Eth ports. The following values are defined:
unknown - the control protocol cannot be determined.
cpHS - G.hs-based discovery and aggregation,
as specified in [G.998.2].
cpBACP - Bonding Aggregation Control Protocol (BACP) --
a frame-based discovery, aggregation, and link
management protocol, as specified in
[G.998.2-Amd2] Annex C."
SYNTAX INTEGER {
unknown(0),
cpHS(1),
cpBACP(2)
}
-------------------------------
-- GBS Notifications group
-------------------------------
-- empty --
Beili & Morgenstern Standards Track [Page 12]
RFC 6767 G.Bond/Ethernet MIB February 2013
-------------------------------
-- GBS group
-------------------------------
g9982PortConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF G9982PortConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for configuration of G.Bond/Eth GBS ports. Entries in
this table MUST be maintained in a persistent manner."
::= { g9982Port 1 }
g9982PortConfEntry OBJECT-TYPE
SYNTAX G9982PortConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the G.Bond/Eth Port Configuration table.
Each entry represents a G.Bond Ethernet port indexed by the
ifIndex.
Note that a G.Bond/Eth GBS port runs on top of a single or
multiple BCE port(s), which are also indexed by the ifIndex."
INDEX { ifIndex }
::= { g9982PortConfTable 1 }
G9982PortConfEntry ::=
SEQUENCE {
g9982PortConfTcAdminType G9982PtmTcType,
g9982PortConfAdminCp G9982CpType
}
g9982PortConfTcAdminType OBJECT-TYPE
SYNTAX G9982PtmTcType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative (desired) PTM-TC encapsulation type of a
G.Bond/Eth port (GBS).
Possible values are:
tc6465(1) - 64/65-octet encapsulation
tcHDLC(2) - HDLC encapsulation
Attempts to set a port to a non-supported PTM-TC encapsulation
type (see g9982PortCapTcTypesSupported) SHALL be rejected
(with the error inconsistentValue).
Beili & Morgenstern Standards Track [Page 13]
RFC 6767 G.Bond/Ethernet MIB February 2013
Changing g9982PortConfTcAdminType is a traffic-disruptive
operation and as such SHALL be done when the link (GBS) is
administratively 'down', as indicated by the ifAdminStatus object
in the IF-MIB.
Attempts to change this object SHALL be rejected (with the error
inconsistentValue) if the link is 'up' or initializing.
This object maps to the TR-159 attribute aEthTcAdminType."
REFERENCE
"[TR-159], Section 5.5.3.4; RFC 2863, IF-MIB, ifAdminStatus"
::= { g9982PortConfEntry 1 }
g9982PortConfAdminCp OBJECT-TYPE
SYNTAX G9982CpType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative (desired) bonding control protocol of a
G.Bond/Eth port (GBS). Possible values are:
cpHS(1) - use G.hs-based protocol (default)
cpBACP(2) - use frame-based BACP
Note that G.hs-based protocol support is mandatory, according to
[G.998.2]. Attempts to set a port to a non-supported bonding
control protocol (e.g., BACP if the value of
g9982PortCapBacpSupported is false) SHALL be rejected
(with the error inconsistentValue).
Changing g9982PortConfAdminCp is a traffic-disruptive
operation and as such SHALL be done when the link (GBS) is
administratively 'down', as indicated by the ifAdminStatus
object in the IF-MIB.
Attempts to change this object SHALL be rejected (with the error
inconsistentValue) if the link is 'up' or initializing.
This object maps to the TR-159 attribute aEthAdminCP."
REFERENCE
"[TR-159], Section 5.5.3.2; RFC 2863, IF-MIB, ifAdminStatus"
DEFVAL { cpHS }
::= { g9982PortConfEntry 2 }
g9982PortCapTable OBJECT-TYPE
SYNTAX SEQUENCE OF G9982PortCapEntry
MAX-ACCESS not-accessible
STATUS current
Beili & Morgenstern Standards Track [Page 14]
RFC 6767 G.Bond/Ethernet MIB February 2013
DESCRIPTION
"Table for capabilities of G.Bond/Eth ports. Entries in this
table MUST be maintained in a persistent manner."
::= { g9982Port 2 }
g9982PortCapEntry OBJECT-TYPE
SYNTAX G9982PortCapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the G.Bond/Eth Port Capability table.
Each entry represents a G.Bond port indexed by the ifIndex.
Note that a G.Bond GBS port runs on top of a single or
multiple BCE port(s), which are also indexed by the ifIndex."
INDEX { ifIndex }
::= { g9982PortCapTable 1 }
G9982PortCapEntry ::=
SEQUENCE {
g9982PortCapTcTypesSupported BITS,
g9982PortCapBacpSupported TruthValue
}
g9982PortCapTcTypesSupported OBJECT-TYPE
SYNTAX BITS {
tc6465(0),
tcHDLC(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTM-TC encapsulation types supported by the G.Bond/Eth port.
This is a bitmap of possible encapsulation types. The various
bit positions are:
tc6465 - GBS is capable of 64/65-octet encapsulation
tcHDLC - GBS is capable of HDLC encapsulation
A desired encapsulation is determined by
g9982PortConfTcAdminType, while g9982PortStatTcOperType
reflects the current operating mode.
This object maps to the TR-159 attribute aEthTcTypesSupported."
REFERENCE
"[TR-159], Section 5.5.3.6"
::= { g9982PortCapEntry 1 }
g9982PortCapBacpSupported OBJECT-TYPE
SYNTAX TruthValue
Beili & Morgenstern Standards Track [Page 15]
RFC 6767 G.Bond/Ethernet MIB February 2013
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the Bonding Aggregation Control Protocol
(BACP) -- the frame-based discovery, aggregation, and link
management protocol specified in [G.998.2-Amd2]) is supported
by the G.Bond/Ethernet port.
A value of true(1) indicates that BACP is supported.
A value of false(2) indicates that BACP is unsupported.
The BACP functionality, if supported, can be enabled or
disabled via g9982AdminCP, while g9982OperCP
reflects the current BACP operating mode.
This object maps to the TR-159 attribute aEthBACPSupported."
REFERENCE
"[TR-159], Section 5.5.3.1; [G.998.2-Amd2], Annex C"
::= { g9982PortCapEntry 2 }
g9982PortStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF G9982PortStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides overall status information of G.Bond
ports, complementing the generic status information from the
ifTable of the IF-MIB. Additional status information about
connected BCEs is available from the relevant line MIBs.
This table contains live data from the equipment. As such,
it is NOT persistent."
::= { g9982Port 3 }
g9982PortStatEntry OBJECT-TYPE
SYNTAX G9982PortStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the G.Bond/Eth Port Status table.
Each entry represents a G.Bond/Eth port indexed by the
ifIndex.
Note that a G.Bond GBS port runs on top of a single or
multiple BCE port(s), which are also indexed by the ifIndex."
INDEX { ifIndex }
::= { g9982PortStatTable 1 }
Beili & Morgenstern Standards Track [Page 16]
RFC 6767 G.Bond/Ethernet MIB February 2013
G9982PortStatEntry ::=
SEQUENCE {
g9982PortStatTcOperType G9982PtmTcType,
g9982PortStatOperCp G9982CpType,
g9982PortStatRxErrors Counter32,
g9982PortStatRxSmallFragments Counter32,
g9982PortStatRxLargeFragments Counter32,
g9982PortStatRxBadFragments Counter32,
g9982PortStatRxLostFragments Counter32,
g9982PortStatRxLostStarts Counter32,
g9982PortStatRxLostEnds Counter32,
g9982PortStatRxOverflows Counter32
}
g9982PortStatTcOperType OBJECT-TYPE
SYNTAX G9982PtmTcType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current operational encapsulation type of the G.Bond/Eth
port.
Possible values are:
tc6465(1) - GBS uses 64/65-octet encapsulation
tcHDLC(2) - GBS uses HDLC encapsulation
The operational PTM-TC encapsulation type can be configured
via g9982PortConfTcAdminType.
This object maps to the TR-159 attribute aEthTcOperType."
REFERENCE
"[TR-159], Section 5.5.3.5"
::= { g9982PortStatEntry 1 }
g9982PortStatOperCp OBJECT-TYPE
SYNTAX G9982CpType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current operational bonding discovery and aggregation control
protocol of the G.Bond/Eth port.
Possible values are:
unknown(0) - the protocol cannot be determined, e.g., when
the GBS is 'down'
cpHS(1) - GBS uses G.hs-based protocol
cpBACP(2) - GBS uses frame-based BACP
The operational discovery and aggregation control protocol can
be configured via the g9982PortConfAdminCp variable.
Beili & Morgenstern Standards Track [Page 17]
RFC 6767 G.Bond/Ethernet MIB February 2013
This object maps to the TR-159 attribute aEthOperCP."
REFERENCE
"[TR-159], Section 5.5.3.3"
::= { g9982PortStatEntry 2 }
g9982PortStatRxErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number of Ethernet frame fragments that have been received
by the bonding function and discarded due to various errors.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other times
as indicated by the value of ifCounterDiscontinuityTime, as
defined in the IF-MIB.
This object maps to the TR-159 attribute aEthRxErrors."
REFERENCE
"[TR-159], Section 5.5.3.7"
::= { g9982PortStatEntry 3 }
g9982PortStatRxSmallFragments OBJECT-TYPE
SYNTAX Counter32
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number of fragments smaller than minFragmentSize (64 bytes)
that have been received by the bonding function and discarded.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other times
as indicated by the value of ifCounterDiscontinuityTime, as
defined in the IF-MIB.
This object maps to the TR-159 attribute aEthRxSmallFragments."
REFERENCE
"[TR-159], Section 5.5.3.8"
::= { g9982PortStatEntry 4 }
g9982PortStatRxLargeFragments OBJECT-TYPE
SYNTAX Counter32
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
Beili & Morgenstern Standards Track [Page 18]
RFC 6767 G.Bond/Ethernet MIB February 2013
DESCRIPTION
"A number of fragments larger than maxFragmentSize (512 bytes)
that have been received by the bonding function and discarded.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other times
as indicated by the value of ifCounterDiscontinuityTime, as
defined in the IF-MIB.
This object maps to the TR-159 attribute aEthRxLargeFragments."
REFERENCE
"[TR-159], Section 5.5.3.9"
::= { g9982PortStatEntry 5 }
g9982PortStatRxBadFragments OBJECT-TYPE
SYNTAX Counter32
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number of fragments that do not fit into the sequence
expected by the frame assembly function and that have been
received and discarded by the bonding function (the frame buffer
is flushed to the next valid frame start).
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other times
as indicated by the value of ifCounterDiscontinuityTime, as
defined in the IF-MIB.
This object maps to the TR-159 attribute aEthRxBadFragments."
REFERENCE
"[TR-159], Section 5.5.3.10"
::= { g9982PortStatEntry 6 }
g9982PortStatRxLostFragments OBJECT-TYPE
SYNTAX Counter32
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number of gaps in the sequence of fragments that have
been received by the bonding function (the frame buffer is
flushed to the next valid frame start, when a fragment or
fragments expected by the frame assembly function are not
received).
Beili & Morgenstern Standards Track [Page 19]
RFC 6767 G.Bond/Ethernet MIB February 2013
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other times
as indicated by the value of ifCounterDiscontinuityTime, as
defined in the IF-MIB.
This object maps to the TR-159 attribute aEthRxLostFragments."
REFERENCE
"[TR-159], Section 5.5.3.11"
::= { g9982PortStatEntry 7 }
g9982PortStatRxLostStarts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number of missing StartOfPacket indicators expected by the
frame assembly function.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other times
as indicated by the value of ifCounterDiscontinuityTime, as
defined in the IF-MIB.
This object maps to the TR-159 attribute aEthRxLostStarts."
REFERENCE
"[TR-159], Section 5.5.3.12"
::= { g9982PortStatEntry 8 }
g9982PortStatRxLostEnds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number of missing EndOfPacket indicators expected by the
frame assembly function.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other times
as indicated by the value of ifCounterDiscontinuityTime, as
defined in the IF-MIB.
This object maps to the TR-159 attribute aEthRxLostEnds."
REFERENCE
"[TR-159], Section 5.5.3.13"
::= { g9982PortStatEntry 9 }
g9982PortStatRxOverflows OBJECT-TYPE
SYNTAX Counter32
Beili & Morgenstern Standards Track [Page 20]
RFC 6767 G.Bond/Ethernet MIB February 2013
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number of fragments, received and discarded by the bonding
function, that would have caused the frame assembly buffer to
overflow.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other times
as indicated by the value of ifCounterDiscontinuityTime, as
defined in the IF-MIB.
This object maps to the TR-159 attribute aEthRxOverflows."
REFERENCE
"[TR-159], Section 5.5.3.14"
::= { g9982PortStatEntry 10 }
-------------------------------
-- GBS Performance Monitoring group
-------------------------------
g9982PM OBJECT IDENTIFIER ::= { g9982Port 4 }
g9982PortPmCurTable OBJECT-TYPE
SYNTAX SEQUENCE OF G9982PortPmCurEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains current Performance Monitoring information
for a G.Bond/Eth port. This table contains live data from the
equipment and as such is NOT persistent."
::= { g9982PM 1 }
g9982PortPmCurEntry OBJECT-TYPE
SYNTAX G9982PortPmCurEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the G.Bond/Eth Port PM table.
Each entry represents a G.Bond/Eth port indexed by the
ifIndex."
INDEX { ifIndex }
::= { g9982PortPmCurTable 1 }
Beili & Morgenstern Standards Track [Page 21]
RFC 6767 G.Bond/Ethernet MIB February 2013
G9982PortPmCurEntry ::=
SEQUENCE {
g9982PortPm15MinValidIntervals HCPerfValidIntervals,
g9982PortPm15MinInvalidIntervals HCPerfInvalidIntervals,
g9982PortPmCur15MinTimeElapsed HCPerfTimeElapsed,
g9982PortPmCur15MinRxErrors HCPerfCurrentCount,
g9982PortPmCur15MinRxSmallFragments HCPerfCurrentCount,
g9982PortPmCur15MinRxLargeFragments HCPerfCurrentCount,
g9982PortPmCur15MinRxBadFragments HCPerfCurrentCount,
g9982PortPmCur15MinRxLostFragments HCPerfCurrentCount,
g9982PortPmCur15MinRxLostStarts HCPerfCurrentCount,
g9982PortPmCur15MinRxLostEnds HCPerfCurrentCount,
g9982PortPmCur15MinRxOverflows HCPerfCurrentCount,
g9982PortPm1DayValidIntervals Unsigned32,
g9982PortPm1DayInvalidIntervals Unsigned32,
g9982PortPmCur1DayTimeElapsed HCPerfTimeElapsed,
g9982PortPmCur1DayRxErrors HCPerfCurrentCount,
g9982PortPmCur1DayRxSmallFragments HCPerfCurrentCount,
g9982PortPmCur1DayRxLargeFragments HCPerfCurrentCount,
g9982PortPmCur1DayRxBadFragments HCPerfCurrentCount,
g9982PortPmCur1DayRxLostFragments HCPerfCurrentCount,
g9982PortPmCur1DayRxLostStarts HCPerfCurrentCount,
g9982PortPmCur1DayRxLostEnds HCPerfCurrentCount,
g9982PortPmCur1DayRxOverflows HCPerfCurrentCount
}
g9982PortPm15MinValidIntervals OBJECT-TYPE
SYNTAX HCPerfValidIntervals
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only number of 15-minute intervals for which the
performance data was collected. The value of this object will
be 96 or the maximum number of 15-minute history intervals
collected by the implementation, unless the measurement was
(re)started recently, in which case the value will be the
number of complete 15-minute intervals for which there are at
least some data.
In certain cases, it is possible that some intervals are
unavailable. In this case, this object reports the maximum
interval number for which data is available.
This object partially maps to the TR-159 attribute
aGroupPerf15MinValidIntervals."
REFERENCE
"[TR-159], Section 5.5.1.32"
::= { g9982PortPmCurEntry 1 }
Beili & Morgenstern Standards Track [Page 22]
RFC 6767 G.Bond/Ethernet MIB February 2013
g9982PortPm15MinInvalidIntervals OBJECT-TYPE
SYNTAX HCPerfInvalidIntervals
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only number of 15-minute intervals for which the
performance data was not always available. The value will
typically be zero, except in cases where the data for some
intervals are not available.
This object partially maps to the TR-159 attribute
aGroupPerf15MinInvalidIntervals."
REFERENCE
"[TR-159], Section 5.5.1.33"
::= { g9982PortPmCurEntry 2 }
g9982PortPmCur15MinTimeElapsed OBJECT-TYPE
SYNTAX HCPerfTimeElapsed
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of seconds that have elapsed since the
beginning of the current 15-minute performance interval.
This object partially maps to the TR-159 attribute
aGroupPerfCurr15MinTimeElapsed."
REFERENCE
"[TR-159], Section 5.5.1.34"
::= { g9982PortPmCurEntry 3 }
g9982PortPmCur15MinRxErrors OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of errored fragments received and discarded
by a G.Bond/Eth port during the current 15-minute performance
interval.
Note that the total number of errored fragments is indicated by
the g9982PortStatRxErrors object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.7"
::= { g9982PortPmCurEntry 4}
Beili & Morgenstern Standards Track [Page 23]
RFC 6767 G.Bond/Ethernet MIB February 2013
g9982PortPmCur15MinRxSmallFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments smaller than minFragmentSize
(64 bytes) that have been received and discarded by a
G.Bond/Eth port during the current 15-minute performance
interval.
Note that the total number of small fragments is indicated by
the g9982PortStatRxSmallFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.8"
::= { g9982PortPmCurEntry 5}
g9982PortPmCur15MinRxLargeFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments larger than maxFragmentSize
(512 bytes) that have been received and discarded by a
G.Bond/Eth port during the current 15-minute performance
interval.
Note that the total number of large fragments is indicated by
the g9982PortStatRxLargeFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.9"
::= { g9982PortPmCurEntry 6}
g9982PortPmCur15MinRxBadFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments that do not fit into the
sequence expected by the frame assembly function and that have
been received and discarded by a G.Bond/Eth port during the
current 15-minute performance interval.
Beili & Morgenstern Standards Track [Page 24]
RFC 6767 G.Bond/Ethernet MIB February 2013
Note that the total number of bad fragments is indicated by
the g9982PortStatRxBadFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.10"
::= { g9982PortPmCurEntry 7}
g9982PortPmCur15MinRxLostFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of gaps in the sequence of fragments
expected by the frame assembly function of a G.Bond/Eth port
during the current 15-minute performance interval.
Note that the total number of these lost fragments is indicated
by the g9982PortStatRxLostFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.11"
::= { g9982PortPmCurEntry 8}
g9982PortPmCur15MinRxLostStarts OBJECT-TYPE
SYNTAX HCPerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of missing StartOfPacket indicators expected
by the frame assembly function of a G.Bond/Eth port during the
current 15-minute performance interval.
Note that the total number of missing StartOfPacket indicators
is indicated by the g9982PortStatRxLostStarts object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.12"
::= { g9982PortPmCurEntry 9}
g9982PortPmCur15MinRxLostEnds OBJECT-TYPE
SYNTAX HCPerfCurrentCount
MAX-ACCESS read-only
STATUS current
Beili & Morgenstern Standards Track [Page 25]
RFC 6767 G.Bond/Ethernet MIB February 2013
DESCRIPTION
"A read-only count of missing EndOfPacket indicators expected
by the frame assembly function of a G.Bond/Eth port during the
current 15-minute performance interval.
Note that the total number of missing EndOfPacket indicators
is indicated by the g9982PortStatRxLostEnds object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.13"
::= { g9982PortPmCurEntry 10}
g9982PortPmCur15MinRxOverflows OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments that have been received and
discarded by a G.Bond/Eth port, which would have caused the
frame assembly buffer to overflow, during the current 15-minute
performance interval.
Note that the total number of fragments that would have caused
the frame assembly buffer to overflow is indicated by the
g9982PortStatRxOverflows object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.14"
::= { g9982PortPmCurEntry 11}
g9982PortPm1DayValidIntervals OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
UNITS "days"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only number of 1-day intervals for which data was
collected. The value of this object will be 7 or the maximum
number of 1-day history intervals collected by the
implementation, unless the measurement was (re)started recently,
in which case the value will be the number of complete 1-day
intervals for which there are at least some data.
In certain cases, it is possible that some intervals are
unavailable. In this case, this object reports the maximum
interval number for which data is available."
Beili & Morgenstern Standards Track [Page 26]
RFC 6767 G.Bond/Ethernet MIB February 2013
REFERENCE
"[TR-159], Section 5.5.1.45"
::= { g9982PortPmCurEntry 12 }
g9982PortPm1DayInvalidIntervals OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
UNITS "days"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only number of 1-day intervals for which data was not
always available. The value will typically be zero, except in
cases where the data for some intervals are not available."
REFERENCE
"[TR-159], Section 5.5.1.46"
::= { g9982PortPmCurEntry 13 }
g9982PortPmCur1DayTimeElapsed OBJECT-TYPE
SYNTAX HCPerfTimeElapsed
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of seconds that have elapsed since the
beginning of the current 1-day performance interval."
REFERENCE
"[TR-159], Section 5.5.1.47"
::= { g9982PortPmCurEntry 14 }
g9982PortPmCur1DayRxErrors OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of errored fragments received and discarded
by a G.Bond/Eth port during the current 1-day performance
interval.
Note that the total number of errored fragments is indicated by
the g9982PortStatRxErrors object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.7"
::= { g9982PortPmCurEntry 15 }
Beili & Morgenstern Standards Track [Page 27]
RFC 6767 G.Bond/Ethernet MIB February 2013
g9982PortPmCur1DayRxSmallFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments smaller than minFragmentSize
(64 bytes) that have been received and discarded by a
G.Bond/Eth port during the current 1-day performance interval.
Note that the total number of small fragments is indicated by
the g9982PortStatRxSmallFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.8"
::= { g9982PortPmCurEntry 16}
g9982PortPmCur1DayRxLargeFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments larger than maxFragmentSize
(512 bytes) that have been received and discarded by a
G.Bond/Eth port during the current 1-day performance interval.
Note that the total number of large fragments is indicated by
the g9982PortStatRxLargeFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.9"
::= { g9982PortPmCurEntry 17}
g9982PortPmCur1DayRxBadFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments that do not fit into the
sequence expected by the frame assembly function and that have
been received and discarded by a G.Bond/Eth port during the
current 1-day performance interval.
Beili & Morgenstern Standards Track [Page 28]
RFC 6767 G.Bond/Ethernet MIB February 2013
Note that the total number of bad fragments is indicated by
the g9982PortStatRxBadFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.10"
::= { g9982PortPmCurEntry 18}
g9982PortPmCur1DayRxLostFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of gaps in the sequence of fragments
expected by the frame assembly function of a G.Bond/Eth port
during the current 1-day performance interval.
Note that the total number of these lost fragments is indicated
by the g9982PortStatRxLostFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.11"
::= { g9982PortPmCurEntry 19}
g9982PortPmCur1DayRxLostStarts OBJECT-TYPE
SYNTAX HCPerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of missing StartOfPacket indicators expected
by the frame assembly function of a G.Bond/Eth port during the
current 1-day performance interval.
Note that the total number of missing StartOfPacket indicators
is indicated by the g9982PortStatRxLostStarts object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.12"
::= { g9982PortPmCurEntry 20}
g9982PortPmCur1DayRxLostEnds OBJECT-TYPE
SYNTAX HCPerfCurrentCount
MAX-ACCESS read-only
STATUS current
Beili & Morgenstern Standards Track [Page 29]
RFC 6767 G.Bond/Ethernet MIB February 2013
DESCRIPTION
"A read-only count of missing EndOfPacket indicators expected
by the frame assembly function of a G.Bond/Eth port during the
current 1-day performance interval.
Note that the total number of missing EndOfPacket indicators
is indicated by the g9982PortStatRxLostEnds object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.13"
::= { g9982PortPmCurEntry 21}
g9982PortPmCur1DayRxOverflows OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments that have been received and
discarded by a G.Bond/Eth port, which would have caused the
frame assembly buffer to overflow, during the current 1-day
performance interval.
Note that the total number of fragments that would have caused
the frame assembly buffer to overflow is indicated by the
g9982PortStatRxOverflows object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.14"
::= { g9982PortPmCurEntry 22}
-- Port PM history: 15-min buckets
g9982PortPm15MinTable OBJECT-TYPE
SYNTAX SEQUENCE OF G9982PortPm15MinEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains historical 15-minute buckets of Performance
Monitoring information for a G.Bond/Eth port (a row for each
15-minute interval, up to 96 intervals).
Entries in this table MUST be maintained in a persistent manner."
::= { g9982PM 2 }
g9982PortPm15MinEntry OBJECT-TYPE
SYNTAX G9982PortPm15MinEntry
Beili & Morgenstern Standards Track [Page 30]
RFC 6767 G.Bond/Ethernet MIB February 2013
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the G.Bond/Eth Port historical 15-minute PM table.
Each entry represents Performance Monitoring data for a
G.Bond/Eth port, indexed by the ifIndex, collected during a
particular 15-minute interval, indexed by the
g9982PortPm15MinIntervalIndex."
INDEX { ifIndex, g9982PortPm15MinIntervalIndex }
::= { g9982PortPm15MinTable 1 }
G9982PortPm15MinEntry ::=
SEQUENCE {
g9982PortPm15MinIntervalIndex Unsigned32,
g9982PortPm15MinIntervalMoniTime HCPerfTimeElapsed,
g9982PortPm15MinIntervalRxErrors HCPerfCurrentCount,
g9982PortPm15MinIntervalRxSmallFragments HCPerfCurrentCount,
g9982PortPm15MinIntervalRxLargeFragments HCPerfCurrentCount,
g9982PortPm15MinIntervalRxBadFragments HCPerfCurrentCount,
g9982PortPm15MinIntervalRxLostFragments HCPerfCurrentCount,
g9982PortPm15MinIntervalRxLostStarts HCPerfCurrentCount,
g9982PortPm15MinIntervalRxLostEnds HCPerfCurrentCount,
g9982PortPm15MinIntervalRxOverflows HCPerfCurrentCount,
g9982PortPm15MinIntervalValid TruthValue
}
g9982PortPm15MinIntervalIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Performance Data Interval number. 1 is the most recent
previous interval; interval 96 is 24 hours ago.
Intervals 2..96 are OPTIONAL.
This object partially maps to the TR-159 attribute
aGroupPerf15MinIntervalNumber."
REFERENCE
"[TR-159], Section 5.5.1.57"
::= { g9982PortPm15MinEntry 1 }
g9982PortPm15MinIntervalMoniTime OBJECT-TYPE
SYNTAX HCPerfTimeElapsed
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
Beili & Morgenstern Standards Track [Page 31]
RFC 6767 G.Bond/Ethernet MIB February 2013
DESCRIPTION
"A read-only count of seconds over which the performance data
was actually monitored. This value will be the same as the
interval duration (900 seconds), except in a situation where
performance data could not be collected for any reason."
::= { g9982PortPm15MinEntry 2 }
g9982PortPm15MinIntervalRxErrors OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of errored fragments received and discarded
by a G.Bond/Eth port during the 15-minute performance history
interval.
Note that the total number of errored fragments is indicated by
the g9982PortStatRxErrors object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.7"
::= { g9982PortPm15MinEntry 3}
g9982PortPm15MinIntervalRxSmallFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments smaller than minFragmentSize
(64 bytes) that have been received and discarded by a
G.Bond/Eth port during the 15-minute performance history
interval.
Note that the total number of small fragments is indicated by
the g9982PortStatRxSmallFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.8"
::= { g9982PortPm15MinEntry 4}
g9982PortPm15MinIntervalRxLargeFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
Beili & Morgenstern Standards Track [Page 32]
RFC 6767 G.Bond/Ethernet MIB February 2013
STATUS current
DESCRIPTION
"A read-only count of fragments larger than maxFragmentSize
(512 bytes) that have been received and discarded by a
G.Bond/Eth port during the 15-minute performance history
interval.
Note that the total number of large fragments is indicated by
the g9982PortStatRxLargeFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.9"
::= { g9982PortPm15MinEntry 5}
g9982PortPm15MinIntervalRxBadFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments that do not fit into the
sequence expected by the frame assembly function and that have
been received and discarded by a G.Bond/Eth port during the
15-minute performance history interval.
Note that the total number of bad fragments is indicated by
the g9982PortStatRxBadFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.10"
::= { g9982PortPm15MinEntry 6}
g9982PortPm15MinIntervalRxLostFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of gaps in the sequence of fragments
expected by the frame assembly function of a G.Bond/Eth port
during the 15-minute performance history interval.
Note that the total number of these lost fragments is indicated
by the g9982PortStatRxLostFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
Beili & Morgenstern Standards Track [Page 33]
RFC 6767 G.Bond/Ethernet MIB February 2013
REFERENCE
"[TR-159], Section 5.5.3.11"
::= { g9982PortPm15MinEntry 7}
g9982PortPm15MinIntervalRxLostStarts OBJECT-TYPE
SYNTAX HCPerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of missing StartOfPacket indicators expected
by the frame assembly function of a G.Bond/Eth port during the
15-minute performance history interval.
Note that the total number of missing StartOfPacket indicators
is indicated by the g9982PortStatRxLostStarts object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.12"
::= { g9982PortPm15MinEntry 8}
g9982PortPm15MinIntervalRxLostEnds OBJECT-TYPE
SYNTAX HCPerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of missing EndOfPacket indicators expected
by the frame assembly function of a G.Bond/Eth port during the
15-minute performance history interval.
Note that the total number of missing EndOfPacket indicators
is indicated by the g9982PortStatRxLostEnds object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.13"
::= { g9982PortPm15MinEntry 9}
g9982PortPm15MinIntervalRxOverflows OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments that have been received and
discarded by a G.Bond/Eth port, which would have caused the
frame assembly buffer to overflow, during the 15-minute
performance history interval.
Beili & Morgenstern Standards Track [Page 34]
RFC 6767 G.Bond/Ethernet MIB February 2013
Note that the total number of fragments that would have caused
the frame assembly buffer to overflow is indicated by the
g9982PortStatRxOverflows object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.14"
::= { g9982PortPm15MinEntry 10}
g9982PortPm15MinIntervalValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only object indicating whether or not this history
bucket contains valid data. A valid bucket is reported as
true(1) and an invalid bucket as false(2).
If this history bucket is invalid, the BTU MUST NOT produce
notifications based upon the value of the counters in this
bucket.
Note that an implementation may decide not to store invalid
history buckets in its database. In such a case, this object
is not required, as only valid history buckets are available
while invalid history buckets are simply not in the database.
This object partially maps to the TR-159 attribute
aGroupPerf15MinIntervalValid."
REFERENCE
"[TR-159], Section 5.5.1.58"
::= { g9982PortPm15MinEntry 11 }
-- Port PM history: 1-day buckets
g9982PortPm1DayTable OBJECT-TYPE
SYNTAX SEQUENCE OF G9982PortPm1DayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains historical 1-day buckets of Performance
Monitoring information for a G.Bond/Eth port (a row for each
1-day interval, up to 7 intervals).
Entries in this table MUST be maintained in a persistent manner."
::= { g9982PM 3 }
g9982PortPm1DayEntry OBJECT-TYPE
SYNTAX G9982PortPm1DayEntry
MAX-ACCESS not-accessible
STATUS current
Beili & Morgenstern Standards Track [Page 35]
RFC 6767 G.Bond/Ethernet MIB February 2013
DESCRIPTION
"An entry in the G.Bond/Eth port historical 1-day PM table.
Each entry represents Performance Monitoring data for such a
port, indexed by the ifIndex, collected during a particular
1-day interval, indexed by the g9982PortPm1DayIntervalIndex."
INDEX { ifIndex, g9982PortPm1DayIntervalIndex }
::= { g9982PortPm1DayTable 1 }
G9982PortPm1DayEntry ::=
SEQUENCE {
g9982PortPm1DayIntervalIndex Unsigned32,
g9982PortPm1DayIntervalMoniTime HCPerfTimeElapsed,
g9982PortPm1DayIntervalRxErrors HCPerfCurrentCount,
g9982PortPm1DayIntervalRxSmallFragments HCPerfCurrentCount,
g9982PortPm1DayIntervalRxLargeFragments HCPerfCurrentCount,
g9982PortPm1DayIntervalRxBadFragments HCPerfCurrentCount,
g9982PortPm1DayIntervalRxLostFragments HCPerfCurrentCount,
g9982PortPm1DayIntervalRxLostStarts HCPerfCurrentCount,
g9982PortPm1DayIntervalRxLostEnds HCPerfCurrentCount,
g9982PortPm1DayIntervalRxOverflows HCPerfCurrentCount,
g9982PortPm1DayIntervalValid TruthValue
}
g9982PortPm1DayIntervalIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..7)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Performance Data Interval number. 1 is the most recent
previous interval; interval 7 is 7 days ago.
Intervals 2..7 are OPTIONAL.
This object partially maps to the TR-159 attribute
aGroupPerf1DayIntervalNumber."
REFERENCE
"[TR-159], Section 5.5.1.62"
::= { g9982PortPm1DayEntry 1 }
g9982PortPm1DayIntervalMoniTime OBJECT-TYPE
SYNTAX HCPerfTimeElapsed
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of seconds over which the performance data
was actually monitored. This value will be the same as the
interval duration (86400 seconds), except in a situation where
performance data could not be collected for any reason.
Beili & Morgenstern Standards Track [Page 36]
RFC 6767 G.Bond/Ethernet MIB February 2013
This object partially maps to the TR-159 attribute
aGroupPerf1DayIntervalMoniSecs."
REFERENCE
"[TR-159], Section 5.5.1.64"
::= { g9982PortPm1DayEntry 2 }
g9982PortPm1DayIntervalRxErrors OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of errored fragments received and discarded
by a G.Bond/Eth port during the 1-day performance history
interval.
Note that the total number of errored fragments is indicated by
the g9982PortStatRxErrors object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.7"
::= { g9982PortPm1DayEntry 3 }
g9982PortPm1DayIntervalRxSmallFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments smaller than minFragmentSize
(64 bytes) that have been received and discarded by a
G.Bond/Eth port during the 1-day performance history interval.
Note that the total number of small fragments is indicated by
the g9982PortStatRxSmallFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.8"
::= { g9982PortPm1DayEntry 4}
g9982PortPm1DayIntervalRxLargeFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
Beili & Morgenstern Standards Track [Page 37]
RFC 6767 G.Bond/Ethernet MIB February 2013
DESCRIPTION
"A read-only count of fragments larger than maxFragmentSize
(512 bytes) that have been received and discarded by a
G.Bond/Eth port during the 1-day performance history interval.
Note that the total number of large fragments is indicated by
the g9982PortStatRxLargeFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.9"
::= { g9982PortPm1DayEntry 5}
g9982PortPm1DayIntervalRxBadFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments that do not fit into the
sequence expected by the frame assembly function and that have
been received and discarded by a G.Bond/Eth port during the
1-day performance history interval.
Note that the total number of bad fragments is indicated by
the g9982PortStatRxBadFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.10"
::= { g9982PortPm1DayEntry 6}
g9982PortPm1DayIntervalRxLostFragments OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of gaps in the sequence of fragments
expected by the frame assembly function of a G.Bond/Eth port
during the 1-day performance history interval.
Note that the total number of these lost fragments is indicated
by the g9982PortStatRxLostFragments object.
This object is inhibited during Unavailable Seconds (UAS)."
Beili & Morgenstern Standards Track [Page 38]
RFC 6767 G.Bond/Ethernet MIB February 2013
REFERENCE
"[TR-159], Section 5.5.3.11"
::= { g9982PortPm1DayEntry 7}
g9982PortPm1DayIntervalRxLostStarts OBJECT-TYPE
SYNTAX HCPerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of missing StartOfPacket indicators expected
by the frame assembly function of a G.Bond/Eth port during the
1-day performance history interval.
Note that the total number of missing StartOfPacket indicators
is indicated by the g9982PortStatRxLostStarts object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.12"
::= { g9982PortPm1DayEntry 8}
g9982PortPm1DayIntervalRxLostEnds OBJECT-TYPE
SYNTAX HCPerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of missing EndOfPacket indicators expected
by the frame assembly function of a G.Bond/Eth port during the
1-day performance history interval.
Note that the total number of missing EndOfPacket indicators
is indicated by the g9982PortStatRxLostEnds object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.13"
::= { g9982PortPm1DayEntry 9}
g9982PortPm1DayIntervalRxOverflows OBJECT-TYPE
SYNTAX HCPerfCurrentCount
UNITS "fragments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only count of fragments that have been received and
discarded by a G.Bond/Eth port, which would have caused the
frame assembly buffer to overflow, during the 1-day performance
history interval.
Beili & Morgenstern Standards Track [Page 39]
RFC 6767 G.Bond/Ethernet MIB February 2013
Note that the total number of fragments that would have caused
the frame assembly buffer to overflow is indicated by the
g9982PortStatRxOverflows object.
This object is inhibited during Unavailable Seconds (UAS)."
REFERENCE
"[TR-159], Section 5.5.3.14"
::= { g9982PortPm1DayEntry 10}
g9982PortPm1DayIntervalValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only object indicating whether or not this history
bucket contains valid data. A valid bucket is reported as
true(1) and an invalid bucket as false(2).
If this history bucket is invalid, the BTU MUST NOT produce
notifications based upon the value of the counters in this
bucket.
Note that an implementation may decide not to store invalid
history buckets in its database. In such a case, this object
is not required, as only valid history buckets are available
while invalid history buckets are simply not in the database.
This object partially maps to the TR-159 attribute
aGroupPerf1DayIntervalValid."
REFERENCE
"[TR-159], Section 5.5.1.63"
::= { g9982PortPm1DayEntry 11 }
-------------------------------
-- BCE group
-------------------------------
g9982BceConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF G9982BceConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for configuration of G.Bond/Eth-specific aspects for the
Bonding Channel Entity (BCE) ports (modems/channels).
Entries in this table MUST be maintained in a persistent
manner."
::= { g9982Bce 1 }
Beili & Morgenstern Standards Track [Page 40]
RFC 6767 G.Bond/Ethernet MIB February 2013
g9982BceConfEntry OBJECT-TYPE
SYNTAX G9982BceConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the G.Bond/Eth BCE Configuration table.
Each entry represents G.998.2-specific aspects of a BCE port
indexed by the ifIndex. Note that a G.Bond/Eth BCE port can be
stacked below a single GBS port, also indexed by the ifIndex."
INDEX { ifIndex }
::= { g9982BceConfTable 1 }
G9982BceConfEntry ::=
SEQUENCE {
g9982BceConfEligibleGroupID PhysAddress,
g9982BceConfPeerEligibleGroupID PhysAddress
}
g9982BceConfEligibleGroupID OBJECT-TYPE
SYNTAX PhysAddress (SIZE(0|6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"BACP Eligible Group ID of a G.Bond/ETH BCE port.
A universally unique 6-octet-long identifier, used by the
OPTIONAL BACP, to determine bonding eligibility. When two BCEs
have the same g9982BceConfEligibleGroupID on a system, they
are eligible to be aggregated on that system. Typically, all
BCEs on a BTU-R device would be assigned the same
g9982BceConfEligibleGroupID, to assert that all of the BCEs
should be in the same bonded group. BCEs with different
g9982BceConfEligibleGroupID values MUST NOT be connected to
the same GBS.
BCEs with the same g9982BceConfEligibleGroupID MAY be
connected to different GBS ports.
This object MUST be instantiated during BACP initialization,
when every BCE belongs to its own GBS. Attempts to change this
object MUST be rejected (with the error inconsistentValue), if
the BCE is aggregated with other BCEs, i.e., more than one BCE
is connected to the same GBS, or if the BCE in question is not
eligible to be bonded with other BCEs having the same value
(e.g., the bonding is limited to a single line card and BCEs are
located on different line cards, or BCEs are the channels of
the same line).
Beili & Morgenstern Standards Track [Page 41]
RFC 6767 G.Bond/Ethernet MIB February 2013
Note that bonding eligibility is reflected in the
ifCapStackTable and its inverse, the ifInvCapStackTable;
as such, any modification of g9982BceConfEligibleGroupID MUST
be reflected in these tables.
A zero-length octet string SHALL be returned on an attempt to
read this object on systems not supporting BACP (the value of
g9982PortCapBacpSupported for the connected GBS is false).
This object maps to the TR-159 attribute
aChannelEligibleGroupID."
REFERENCE
"[TR-159], Section 5.5.7.3"
::= { g9982BceConfEntry 1 }
g9982BceConfPeerEligibleGroupID OBJECT-TYPE
SYNTAX PhysAddress (SIZE(0|6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BACP Eligible Group ID of a peer G.Bond/ETH BCE port, most
recently received by the local BCE via a Local info TLV BACPDU
message from the peer BCE.
A universally unique 6-octet-long identifier, used by the
OPTIONAL BACP, to determine bonding eligibility.
BCEs with different g9982BceConfPeerEligibleGroupID values
MUST NOT be connected to the same GBS.
BCEs with the same g9982BceConfPeerEligibleGroupID MAY be
connected to different GBS ports.
A zero-length octet string SHALL be returned on an attempt to
read this object on systems not supporting BACP (the value of
g9982PortCapBacpSupported for the connected GBS is false)
or when no BACPDUs have been received from the peer BCE.
This object maps to the G.998.2-Amd2 attribute
Remote Group ID."
REFERENCE
"[G.998.2-Amd2], Appendix C.3.1.6"
::= { g9982BceConfEntry 2 }
g9982BceStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF G9982BceStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides common status information of G.Bond/Eth
BCE ports.
Beili & Morgenstern Standards Track [Page 42]
RFC 6767 G.Bond/Ethernet MIB February 2013
This table contains live data from the equipment. As such,
it is NOT persistent."
::= { g9982Bce 2 }
g9982BceStatEntry OBJECT-TYPE
SYNTAX G9982BceStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the G.Bond/Eth BCE Status table.
Each entry represents common aspects of a G.Bond/Eth BCE port
indexed by the ifIndex. Note that a BCE port can be stacked
below a single GBS port, also indexed by the ifIndex,
possibly together with other BCE ports."
INDEX { ifIndex }
::= { g9982BceStatTable 1 }
G9982BceStatEntry ::=
SEQUENCE {
g9982BceStatTcInCodingErrors Counter32,
g9982BceStatTcInCrcErrors Counter32
}
g9982BceStatTcInCodingErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number of PTM-TC encapsulation errors. This counter is
incremented for each encapsulation error detected by the
PTM-TC receive function.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other times
as indicated by the value of ifCounterDiscontinuityTime, as
defined in the IF-MIB.
This object maps to the TR-159 attribute
aChannelPtmTcRxCodingViolations."
REFERENCE
"[TR-159], Section 5.5.7.8"
::= { g9982BceStatEntry 1 }
g9982BceStatTcInCrcErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
Beili & Morgenstern Standards Track [Page 43]
RFC 6767 G.Bond/Ethernet MIB February 2013
DESCRIPTION
"A number of PTM-TC CRC errors. This counter is incremented
for each CRC error detected by the PTM-TC receive function.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other times
as indicated by the value of ifCounterDiscontinuityTime, as
defined in the IF-MIB.
This object maps to the TR-159 attribute
aChannelPtmTcRxCrcErrors."
REFERENCE
"[TR-159], Section 5.5.7.9"
::= { g9982BceStatEntry 2 }
-------------------------------
-- Conformance Statements
-------------------------------
g9982Groups OBJECT IDENTIFIER
::= { g9982Conformance 1 }
g9982Compliances OBJECT IDENTIFIER
::= { g9982Conformance 2 }
-- Object groups
g9982BasicGroup OBJECT-GROUP
OBJECTS {
g9982PortCapTcTypesSupported,
g9982PortCapBacpSupported,
g9982PortConfTcAdminType,
g9982PortStatTcOperType,
g9982PortStatRxErrors,
g9982PortStatRxSmallFragments,
g9982PortStatRxLargeFragments,
g9982PortStatRxBadFragments,
g9982PortStatRxLostFragments,
g9982PortStatRxLostStarts,
g9982PortStatRxLostEnds,
g9982PortStatRxOverflows,
g9982BceStatTcInCodingErrors,
g9982BceStatTcInCrcErrors
}
STATUS current
Beili & Morgenstern Standards Track [Page 44]
RFC 6767 G.Bond/Ethernet MIB February 2013
DESCRIPTION
"A collection of objects representing management information
for G.Bond/Eth GBS ports."
::= { g9982Groups 1 }
g9982BacpGroup OBJECT-GROUP
OBJECTS {
g9982PortConfAdminCp,
g9982PortStatOperCp,
g9982BceConfEligibleGroupID,
g9982BceConfPeerEligibleGroupID
}
STATUS current
DESCRIPTION
"A collection of objects representing management information
for the OPTIONAL frame-based Bonding Aggregation Control
Protocol (BACP) used by G.Bond/Eth GBS ports instead of the
mandatory G.hs-based discovery and aggregation protocol."
::= { g9982Groups 2 }
g9982BceGroup OBJECT-GROUP
OBJECTS {
g9982BceStatTcInCodingErrors,
g9982BceStatTcInCrcErrors
}
STATUS current
DESCRIPTION
"A collection of objects representing OPTIONAL management
information for G.Bond/Eth BCE ports."
::= { g9982Groups 3 }
g9982PerfCurrGroup OBJECT-GROUP
OBJECTS {
g9982PortPm15MinValidIntervals,
g9982PortPm15MinInvalidIntervals,
g9982PortPmCur15MinTimeElapsed,
g9982PortPmCur15MinRxErrors,
g9982PortPmCur15MinRxSmallFragments,
g9982PortPmCur15MinRxLargeFragments,
g9982PortPmCur15MinRxBadFragments,
g9982PortPmCur15MinRxLostFragments,
g9982PortPmCur15MinRxLostStarts,
g9982PortPmCur15MinRxLostEnds,
g9982PortPmCur15MinRxOverflows,
g9982PortPm1DayValidIntervals,
g9982PortPm1DayInvalidIntervals,
g9982PortPmCur1DayTimeElapsed,
Beili & Morgenstern Standards Track [Page 45]
RFC 6767 G.Bond/Ethernet MIB February 2013
g9982PortPmCur1DayRxErrors,
g9982PortPmCur1DayRxSmallFragments,
g9982PortPmCur1DayRxLargeFragments,
g9982PortPmCur1DayRxBadFragments,
g9982PortPmCur1DayRxLostFragments,
g9982PortPmCur1DayRxLostStarts,
g9982PortPmCur1DayRxLostEnds,
g9982PortPmCur1DayRxOverflows
}
STATUS current
DESCRIPTION
"A collection of objects supporting OPTIONAL current Performance
Monitoring information for G.Bond/Eth ports."
::= { g9982Groups 4 }
g9982Perf15MinGroup OBJECT-GROUP
OBJECTS {
g9982PortPm15MinIntervalMoniTime,
g9982PortPm15MinIntervalRxErrors,
g9982PortPm15MinIntervalRxSmallFragments,
g9982PortPm15MinIntervalRxLargeFragments,
g9982PortPm15MinIntervalRxBadFragments,
g9982PortPm15MinIntervalRxLostFragments,
g9982PortPm15MinIntervalRxLostStarts,
g9982PortPm15MinIntervalRxLostEnds,
g9982PortPm15MinIntervalRxOverflows,
g9982PortPm15MinIntervalValid
}
STATUS current
DESCRIPTION
"A collection of objects supporting OPTIONAL historical
Performance Monitoring information for G.Bond/Eth ports, during
previous 15-minute intervals."
::= { g9982Groups 5 }
g9982Perf1DayGroup OBJECT-GROUP
OBJECTS {
g9982PortPm1DayIntervalMoniTime,
g9982PortPm1DayIntervalRxErrors,
g9982PortPm1DayIntervalRxSmallFragments,
g9982PortPm1DayIntervalRxLargeFragments,
g9982PortPm1DayIntervalRxBadFragments,
g9982PortPm1DayIntervalRxLostFragments,
g9982PortPm1DayIntervalRxLostStarts,
g9982PortPm1DayIntervalRxLostEnds,
g9982PortPm1DayIntervalRxOverflows,
g9982PortPm1DayIntervalValid
}
Beili & Morgenstern Standards Track [Page 46]
RFC 6767 G.Bond/Ethernet MIB February 2013
STATUS current
DESCRIPTION
"A collection of objects supporting OPTIONAL historical
Performance Monitoring information for G.Bond/Eth ports, during
previous 1-day intervals."
::= { g9982Groups 6 }
-------------------------------
-- Compliance Statements
-------------------------------
g9982Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for G.Bond Ethernet interfaces.
Compliance with the following external compliance statements
is REQUIRED:
MIB Module Compliance Statement
---------- --------------------
IF-MIB ifCompliance3
GBOND-MIB gBondCompliance"
MODULE -- this module
MANDATORY-GROUPS {
g9982BasicGroup
}
GROUP g9982BceGroup
DESCRIPTION
"Support for this group is OPTIONAL."
GROUP g9982BacpGroup
DESCRIPTION
"Support for this group is OPTIONAL and only required for
implementations supporting BACP."
GROUP g9982PerfCurrGroup
DESCRIPTION
"Support for this group is only required for implementations
supporting Performance Monitoring."
GROUP g9982Perf15MinGroup
DESCRIPTION
"Support for this group is only required for implementations
supporting 15-minute historical Performance Monitoring."
Beili & Morgenstern Standards Track [Page 47]
RFC 6767 G.Bond/Ethernet MIB February 2013
GROUP g9982Perf1DayGroup
DESCRIPTION
"Support for this group is only required for implementations
supporting 1-day historical Performance Monitoring."
OBJECT g9982PortCapTcTypesSupported
SYNTAX BITS {
tc6465(0),
tcHDLC(1)
}
DESCRIPTION
"Support for all TC types is not required. However, at least
one value SHALL be supported."
OBJECT g9982PortCapBacpSupported
SYNTAX TruthValue
DESCRIPTION
"Support for BACP is OPTIONAL; therefore, a value of false(2)
SHALL be supported."
OBJECT g9982PortConfTcAdminType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required (needed only for GBS
supporting more than a single TC encapsulation type, i.e.,
tc6465 and tcHDLC)."
OBJECT g9982PortConfAdminCp
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required (needed only for GBS
supporting BACP in addition to mandatory G.hs-based bonding
discovery and aggregation protocol)."
::= { g9982Compliances 1 }
END
Beili & Morgenstern Standards Track [Page 48]
RFC 6767 G.Bond/Ethernet MIB February 2013
7. Security Considerations
There are a number of managed objects defined in this MIB module with
a MAX-ACCESS clause of read-write and/or read-create. Such objects
may be considered sensitive or vulnerable in some network
environments. The support for SET operations in a non-secure
environment without proper protection can have a negative effect on
network operations. These are the tables and objects and their
sensitivity/vulnerability:
o Changing of g9982PortConfTable configuration parameters (e.g.,
g9982PortConfTcAdminType) may lead to a complete service
interruption in cases where the specified PTM-TC encapsulation
type is not supported by the remote end.
o Changing of g9982BceConfTable configuration parameters (e.g.,
g9982BceConfEligibleGroupID) may lead to preventing a non-bonded
BCE from being bonded in any bonding group, or false advertisement
of bonding eligibility (e.g., between BCEs residing on different
line cards in an application that does not support cross-card
bonding).
Some of the readable objects in this MIB module (i.e., objects with a
MAX-ACCESS other than not-accessible) may be considered sensitive or
vulnerable in some network environments since, collectively, they
provide information about the performance of network interfaces and
can reveal some aspects of their configuration.
It is thus important to control even GET and/or NOTIFY access to
these objects and possibly to even encrypt the values of these
objects when sending them over the network via SNMP. These are the
tables and objects and their sensitivity/vulnerability:
o g9982PortStatTable - objects in this table (e.g.,
g9982PortStatTcOperType) provide status information for the G.Bond
port, which may aid in deciphering of the G.Bond/ETH
transmissions.
SNMP versions prior to SNMPv3 did not include adequate security.
Even if the network itself is secure (for example by using IPsec),
there is no control as to who on the secure network is allowed to
access and GET/SET (read/change/create/delete) the objects in this
MIB module.
Implementations SHOULD provide the security features described by the
SNMPv3 framework (see [RFC3410]), and implementations claiming
compliance to the SNMPv3 standard MUST include full support for
authentication and privacy via the User-based Security Model (USM)
Beili & Morgenstern Standards Track [Page 49]
RFC 6767 G.Bond/Ethernet MIB February 2013
[RFC3414] with the AES cipher algorithm [RFC3826]. Implementations
MAY also provide support for the Transport Security Model (TSM)
[RFC5591] in combination with a secure transport such as SSH
[RFC5592] or TLS/DTLS [RFC6353].
Further, deployment of SNMP versions prior to SNMPv3 is NOT
RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of this MIB module is properly configured to give access to
the objects only to those principals (users) that have legitimate
rights to indeed GET or SET (change/create/delete) them.
8. IANA Considerations
IANA has assigned 264 as the object identifier for the g9982MIB
MODULE-IDENTITY in the MIB-2 transmission sub-tree
<http://www.iana.org/>.
9. Acknowledgments
This document was produced by the [ADSLMIB] working group.
Special thanks to Dan Romascanu for his meticulous review of this
text.
10. References
10.1. Normative References
[802.3] IEEE, "IEEE Standard for Information technology -
Telecommunications and information exchange between
systems - Local and metropolitan area networks - Specific
requirements - Part 3: Carrier Sense Multiple Access with
Collision Detection (CSMA/CD) Access Method and Physical
Layer Specifications", IEEE Std 802.3-2005, December 2005.
[G.998.2] ITU-T, "Ethernet-based multi-pair bonding", ITU-T
Recommendation G.998.2, January 2005,
<http://www.itu.int/rec/T-REC-G.998.2/en>.
[G.998.2-Amd2]
ITU-T, "Ethernet-based multi-pair bonding Amendment 2",
ITU-T Recommendation G.998.2/Amd.2, December 2007,
<http://www.itu.int/rec/T-REC-G.998.2-200712-I!Amd2/en>.
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
Beili & Morgenstern Standards Track [Page 50]
RFC 6767 G.Bond/Ethernet MIB February 2013
[RFC2578] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Structure of Management Information
Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.
[RFC2579] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Textual Conventions for SMIv2",
STD 58, RFC 2579, April 1999.
[RFC2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder,
"Conformance Statements for SMIv2", STD 58, RFC 2580,
April 1999.
[RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces Group
MIB", RFC 2863, June 2000.
[RFC3414] Blumenthal, U. and B. Wijnen, "User-based Security Model
(USM) for version 3 of the Simple Network Management
Protocol (SNMPv3)", STD 62, RFC 3414, December 2002.
[RFC3705] Ray, B. and R. Abbi, "High Capacity Textual Conventions
for MIB Modules Using Performance History Based on 15
Minute Intervals", RFC 3705, February 2004.
[RFC3826] Blumenthal, U., Maino, F., and K. McCloghrie, "The
Advanced Encryption Standard (AES) Cipher Algorithm in the
SNMP User-based Security Model", RFC 3826, June 2004.
[RFC5591] Harrington, D. and W. Hardaker, "Transport Security Model
for the Simple Network Management Protocol (SNMP)",
RFC 5591, June 2009.
[RFC5592] Harrington, D., Salowey, J., and W. Hardaker, "Secure
Shell Transport Model for the Simple Network Management
Protocol (SNMP)", RFC 5592, June 2009.
[RFC6353] Hardaker, W., "Transport Layer Security (TLS) Transport
Model for the Simple Network Management Protocol (SNMP)",
RFC 6353, July 2011.
[RFC6765] Beili, E. and M. Morgenstern, "xDSL Multi-Pair Bonding
(G.Bond) MIB", RFC 6765, February 2013.
[TR-159] Beili, E. and M. Morgenstern, "Management Framework for
xDSL Bonding", Broadband Forum Technical Report TR-159,
December 2008, <http://www.broadband-forum.org/technical/
download/TR-159.pdf>.
Beili & Morgenstern Standards Track [Page 51]
RFC 6767 G.Bond/Ethernet MIB February 2013
10.2. Informative References
[ADSLMIB] IETF, "ADSL MIB (adslmib) Charter",
<http://datatracker.ietf.org/wg/adslmib/charter/>.
[G.991.2] ITU-T, "Single-pair high-speed digital subscriber line
(SHDSL) transceivers", ITU-T Recommendation G.991.2,
December 2003, <http://www.itu.int/rec/T-REC-G.991.2/en>.
[G.993.1] ITU-T, "Very high speed digital subscriber line
transceivers (VDSL)", ITU-T Recommendation G.993.1,
June 2004, <http://www.itu.int/rec/T-REC-G.993.1/en>.
[G.994.1] ITU-T, "Handshake procedures for digital subscriber line
(DSL) transceivers", ITU-T Recommendation G.994.1,
February 2007, <http://www.itu.int/rec/T-REC-G.994.1/en>.
[IEEE802.3.1]
IEEE, "IEEE P802.3.1 Revision to IEEE Std 802.3.1-2011
(IEEE 802.3.1a) Ethernet MIBs Task Force", January 2012,
<http://grouper.ieee.org/groups/802/3/1/>.
[RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart,
"Introduction and Applicability Statements for Internet-
Standard Management Framework", RFC 3410, December 2002.
[RFC3593] Tesink, K., "Textual Conventions for MIB Modules Using
Performance History Based on 15 Minute Intervals",
RFC 3593, September 2003.
[RFC3635] Flick, J., "Definitions of Managed Objects for the
Ethernet-like Interface Types", RFC 3635, September 2003.
[RFC3728] Ray, B. and R. Abbi, "Definitions of Managed Objects for
Very High Speed Digital Subscriber Lines (VDSL)",
RFC 3728, February 2004.
[RFC4181] Heard, C., "Guidelines for Authors and Reviewers of MIB
Documents", BCP 111, RFC 4181, September 2005.
[RFC4319] Sikes, C., Ray, B., and R. Abbi, "Definitions of Managed
Objects for High Bit-Rate DSL - 2nd generation (HDSL2) and
Single-Pair High-Speed Digital Subscriber Line (SHDSL)
Lines", RFC 4319, December 2005.
Beili & Morgenstern Standards Track [Page 52]
RFC 6767 G.Bond/Ethernet MIB February 2013
[RFC4836] Beili, E., "Definitions of Managed Objects for
IEEE 802.3 Medium Attachment Units (MAUs)", RFC 4836,
April 2007.
[RFC5066] Beili, E., "Ethernet in the First Mile Copper (EFMCu)
Interfaces MIB", RFC 5066, November 2007.
Authors' Addresses
Edward Beili
Actelis Networks
25 Bazel St.
Petach-Tikva 49103
Israel
Phone: +972-3-924-3491
EMail: edward.beili@actelis.com
Moti Morgenstern
ECI Telecom
30 Hasivim St.
Petach-Tikva 4951169
Israel
Phone: +972-3-926-6258
EMail: moti.morgenstern@ecitele.com
Beili & Morgenstern Standards Track [Page 53]